Agilent n9010a руководство

Краткое содержание страницы № 1

Agilent X-Series
Signal Analyzer
This manual provides documentation for the
following X-Series Analyzer:
EXA Signal Analyzer N9010A
N9010A EXA Specifications
Guide
(Comprehensive Reference Data)

Краткое содержание страницы № 2

Notices © Agilent Technologies, Inc. 2007 — 2010 licensed as “Commercial computer soft- Manual Part Number ware” as defined in DFAR 252.227-7014 No part of this manual may be reproduced N9010-90025 (June 1995), or as a “commercial item” as in any form or by any means (including Supersedes: August 2009 defined in FAR 2.101(a) or as “Restricted electronic storage and retrieval or transla- computer software” as defined in FAR tion into a foreign language) without prior 52.227-19 (June 1987

Краткое содержание страницы № 3

Notice Warranty This Agilent technologies instrument product is warranted against defects in material and workmanship for a period of one year from the date of shipment. During the warranty period, Agilent Technologies will, at its option, either repair or replace products that prove to be defective. For warranty service or repair, this product must be returned to a service facility designated by Agilent Technologies. Buyer shall prepay shipping charges to Agilent Technologies and Agilent Tec

Краткое содержание страницы № 4

4

Краткое содержание страницы № 5

Contents 1. Agilent EXA Signal Analyzer Definitions and Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Conditions Required to Meet Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Certificati

Краткое содержание страницы № 6

Contents Power Suite Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Channel Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Occupied Bandwidth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Adjacent Channel Power (ACP) . . .

Краткое содержание страницы № 7

Contents 5. Option PFR — Precision Frequency Reference Specifications Affected by Precision Frequency Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 6. I/Q Analyzer Specifications Affected by I/Q Analyzer:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Краткое содержание страницы № 8

Contents (EVM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 Power vs. Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 EDGE Power vs. Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 Power Ramp Relative Accuracy

Краткое содержание страницы № 9

Contents AM Rejection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 Residual PM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 Measurement Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 12. Noise Figure Measurement A

Краткое содержание страницы № 10

Contents Occupied Bandwidth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 Spectrum Emission Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 Spurious Emissions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184 Code Domain . . . . . . . . . . . . . . .

Краткое содержание страницы № 11

Contents 20. DVB-T/H Measurement Application N6153A, DVB-T/H Measurements Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 Channel Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 Channel Power with Shoulder Attenuation View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 Power Statistics CCDF . . . . . . .

Краткое содержание страницы № 12

Contents Frequency Points per Span . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248 Resolution Bandwidth (RBW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249 Range . . . . . . . . . . . . . . . .

Краткое содержание страницы № 13

1 Agilent EXA Signal Analyzer This chapter contains the specifications for the core signal analyzer. The specifications and characteristics for the measurement applications and options are covered in the chapters that follow. 13

Краткое содержание страницы № 14

Agilent EXA Signal Analyzer Definitions and Requirements Definitions and Requirements This book contains signal analyzer specifications and supplemental information. The distinction among specifications, typical performance, and nominal values are described as follows. Definitions • Specifications describe the performance of parameters covered by the product warranty (temperature = 5 to 50°C, unless otherwise noted). • 95th percentile values indicate the breadth of the population (≈2σ) of perf

Краткое содержание страницы № 15

Agilent EXA Signal Analyzer Frequency and Time Frequency and Time Description Specifications Supplemental Information Frequency Range Maximum Frequency Option 503 3.6 GHz Option 507 7 GHz Option 513 13.6 GHz Option 526 26.5 GHz Preamp Option P03 3.6 GHz Minimum Frequency Preamp AC Coupled DC Coupled Off 10 MHz 9 kHz On 10 MHz 100 kHz b Band Harmonic Mixing LO Multiple (N ) Mode a Band Overlaps 0 (9 kHz to 3.6 GHz) 1 Options 503,507, 513, 526 1− 1 (3.5 GHz to 7 GHz) 1 Option 507 1−

Краткое содержание страницы № 16

Agilent EXA Signal Analyzer Frequency and Time a. In the band overlap regions, for example, 3.5 to 3.6 GHz, the analyzer may use either band for measurements, in this example Band 0 or Band 1. The analyzer gives preference to the band with the better overall specifications (which is the lower numbered band for all frequencies below 26 GHz), but will choose the other band if doing so is necessary to achieve a sweep having minimum band crossings. For example, with CF = 3.58 GHz, with a span of

Краткое содержание страницы № 17

Agilent EXA Signal Analyzer Frequency and Time Description Specifications Supplemental Information −6 Achievable Initial Calibration ±1.4 × 10 Accuracy −8 Settability ±2 × 10 c Residual FM ≤10 Hz × N p-p in 20 ms , nominal Center Frequency = 1 GHz 10 Hz RBW, 10 Hz VBW a. Calibration accuracy depends on how accurately the frequency standard was adjusted to 10 MHz. If the adjustment procedure is followed, the calibration accuracy is given by the specifi- cation “Achievable Initial

Краткое содержание страницы № 18

Agilent EXA Signal Analyzer Frequency and Time Description Specifications Supplemental Information Precision Frequency Reference (Option PFR) Accuracy ±[(time since last adjustment × aging rate) + temperature stability + calibration a b accuracy ] Temperature Stability −8 20 to 30 °C ±1.5 × 10 −8 5 to 50 °C ±5 × 10 −10 Aging Rate ±5 × 10 /day (nominal) Total Aging −7 1 Year ±1 × 10 −7 2 Years ±1.5 × 10 −9 Settability ±2 × 10 c Warm-up and Retrace −7 300 s after turn on

Краткое содержание страницы № 19

Agilent EXA Signal Analyzer Frequency and Time d. The achievable calibration accuracy at the beginning of the calibration cycle includes these effects: 1) Temperature difference between the calibration environment and the use environment 2) Orientation relative to the gravitation field changing between the calibration environment and the use environment 3) Retrace effects in both the calibration environment and the use environment due to turning the instrument power off. 4) Settability e.

Краткое содержание страницы № 20

Agilent EXA Signal Analyzer Frequency and Time Description Specifications Supplemental Information c Frequency Readout Accuracy ±(marker freq. × freq. ref. accy. + 0.25% Single detector only a × span + 5% × RBW + 2 Hz + 0.5 × b horizontal resolution ) d ±0.0032% (nominal) Example for EMC a. The warranted performance is only the sum of all errors under autocoupled conditions. Under non-autocoupled conditions, the frequency readout accuracy will nominally meet the specifica- tion equation, exc

  • Bookmarks

Quick Links

Agilent EXA Signal Analyzer N9010A

Configuration Guide

This EXA configuration guide will help you determine

which performance options, measurement applications,

accessories, and services to include with your new

EXA or to add as upgrades to an existing EXA.

N9010A EXA

Signal Analyzer

Eliminating the Compromise Between speed and price

loading

Related Manuals for Agilent Technologies N9010A

Summary of Contents for Agilent Technologies N9010A

  • Page 1
    Agilent EXA Signal Analyzer N9010A Configuration Guide This EXA configuration guide will help you determine which performance options, measurement applications, accessories, and services to include with your new EXA or to add as upgrades to an existing EXA. N9010A EXA…
  • Page 2
    Select maximum frequency range (required option; frequency range not upgradeable) Description Option number Additional information Frequency range, 9 kHz to 3.6 GHz N9010A-503 Comes standard with 10 MHz analysis bandwidth Frequency range, 9 kHz to 7 GHz N9010A-507 Comes standard with 10 MHz analysis bandwidth Frequency range, 9 kHz to 13.6 GHz…
  • Page 3
    Add a preamplifi er (preamplifi ers are not standard) Description Option number For low level signal detection Preamplifi er, 100 kHz to 3.6 GHz N9010A-P03 +20 dB: 100 kHz to 3.6 GHz Compatble with all frequency range options Step 6. Add Optional features…
  • Page 4
    Step 8. Choose measurement application software and its license type (Continued) Description Ordering number Additional information Fixed Transportable Licenses Licenses GSM/EDGE measurement N9071A-2FP N9071A-2TP Adds one button, standard compliant, GSM/GPRS/EDGE application measurement capability EDGE Evolution N9071A-3FP N9071A-3TP Adds EDGE Evolution (EGPRS2) measurements in EVM, measurement application (requires (requires…
  • Page 5
    Step 8. Choose measurement application software and its license type (Continued) Description Ordering number Additional information Fixed Transportable Licenses Licenses iDEN/WiDEN/MotoTalk N6149A-2FP N6149A-2TP measurement application DVB-T/H measurement N6153A-2FP N6153A-2TP Adds one-button, standard based power measurements and application modulation analysis of the DVB-T/H application DTMB measurement N6156A-2FP N6156A-2TP…
  • Page 6
    Step 9. Add the following options if you choose 89601A Description Option number Additional information Basic VSA software 89601A-200 Required Hardware connectivity 80601A-300 Required Flexible vector modulation analysis 89601A-AYA 3G modulation analysis bundle 89601A-B7N This is an ordering convenience equivalent to Options B7T, B7U, B7W, B7X ®…
  • Page 7
    Provides two side carrying straps, four rear feet and four bottom feet with a tilt stand; a front panel protective cover is included Portable confi guration N9010A-PRC Provides a convenient, pivoting carrying handle and rubber protective corners and end guards; this confi guration is intended for applications requiring more rugged packaging, such as in the fi…
  • Page 8: Add Accessories

    Compact design fits in N9010A-BAG accessory pouch for convenient storage Accessory pouch N9010A-BAG Easily store and carry the N9010A-KB2 keyboard and USB mouse in this attachable pouch Minimum loss pad, 50 to 75 Ωs N9010A-MLP 50-Ω type-N male to 75 Ω BNC female adapter…

  • Page 9
    Step 13. Add calibration, technical training, support and upgrade services Description Ordering number Additional information Commercial calibration N9010A-UK6 Calibration certificate only available at time of certificate with test data instrument purchase; only provides measurement results ISO 17025 Compliant N9010A-1A7 Provides ISO 17025A compliant calibration from factory…
  • Page 10: Instrument Upgrades

    None None 1, 2 Keyboard, USB interface N9010AK-KYB None US 65 Key USB keyboard N9010AK-KB2 None Accessory Pouch N9010AK-BAG None 1. Please see page 13 for a picture of this option 2. Does not fi t in N9010A-BAG accessory pouch…

  • Page 11
    Instrument Upgrades (continued) Minimum loss pad, 50 to 75 Ωs N9010AK-MLP None None (type-N to BNC) Mouse, USB interface N9010AK-MSE None None USB storage device loaded with N9010AK-SWM None None EXA instrument software Rack mount kit N9010AK-1CM None Not compatible with PRC, 1CP, 1CN, 1CR Front handle kit N9010AK-1CN…
  • Page 12: Other Information

    Other Information Connectivity (included standard) 6 USB 2.0 type-A ports connect up to six USB devices to the EXA without using a hub; EXA behaves like a host controller; USB 2.0 compatible ports • two on front • four on the back 1 USB 2.0 type-B port EXA behaves like a USB device(client);…

  • Page 13
    Kit to add portable new instrument configuration purchase; for – N9010AK-PRC additional covers – N9010AK-CVR Keyboard, USB interface – N9010A-KYB Smaller keyboard, USB interface – N9010A-KB2 USB DVD-ROM/CD-R/RW drive – N9010A-DVR Mouse, USB interface Standard USB storage device – N9010A-EFM…
  • Page 14
    Portable configuration includes pivoting carrying handle and protective corner rubber guards (front protective cover comes standard) – N9010A-PRC N9010A-PRC portable configuration N9010A EXA signal analyzer and N9010A-BAG optional bag Hard transit case – N9010A-HTC…
  • Page 15
    Literature Resources Literature title Literature number Agilent EXA Signal Analyzers Brochure 5989-6527EN Data Sheet 5989-6529EN Confi guration Guide 5989-6531EN Agilent MXA Signal Analyzers Brochure 5989-5047EN Data Sheet 5989-4942EN Confi guration Guide 5989-4943EN Option BBA: Analog Baseband IQ Inputs Technical Overview 5989-6538EN Agilent X-Series Signal Analyzers (MXA/EXA) Demonstration Guide…
  • Page 16
    Used under license. without notice. WiMAX, Mobile WiMAX, and WiMAX Forum are trademarks of the WiMAX Forum. © Agilent Technologies, Inc. 2010 Printed in USA, April 12, 2010 Windows and MS Windows are U.S.registered trademarks of Microsoft Corporation. 5989-6531EN Adobe, the Adobe Logo, Acrobat and the Acrobat Logo are trademarks of Adobe Systems Incorporated.

background image

Agilent X-Series

Signal Analyzer

N9010A EXA

Specifications Guide

(Comprehensive Reference Data)

This manual provides documentation for the

following X-Series Analyzer:

EXA Signal Analyzer N9010A

  1. Manuals
  2. Brands
  3. Agilent Technologies Manuals
  4. Measuring Instruments
  5. EXA N9010A

Manuals and User Guides for Agilent Technologies EXA N9010A. We have 2 Agilent Technologies EXA N9010A manuals available for free PDF download: User Manual, Programmer’s Manual

Still not convinced?

Already more than 1086851 people joined to us!

 Join

Subscribe to Newsletter
Enter email to receive a newsletter about updates.

EnglishEnglishРусскийРусский

The collection of popular instruction manuals and user guides
© All rights reserved. Made with by Manualza!

Понравилась статья? Поделить с друзьями:
  • Двигатель awt руководство
  • Капсулы утрожестан 200 инструкция по применению отзывы
  • Кофемашина борк с700 инструкция по очистке
  • Анион 7040 руководство по эксплуатации
  • Амбробене сироп инструкция по применению взрослым отхаркивающее цена