  • Page 1
    APPA 607 User Manual…
  • Page 2: Safety Information

    Safety sheet Warning Warning Safety sheet ……..

  • Page 3: Unsafe Voltage

    CAUTION ˙ Disconnect the test leads from the test points before chang- ing the position of the function rotary switch. ˙ Never connect a source of voltage with the function rotary switch in Ω, ,°C ,mA, INSULATION position. ˙ Do not expose Meter to extremes in temperature or high humidity.

  • Page 4
    The Meter Description Front Panel Illustration 1. LCD display : 10000 counts . 2. Push-buttons for features. 3. Rotary switch for turn the Power On / Off and select the function. 4. Input Terminal for Insulation function. 5. Input Terminal for V,Ω, , Hz, °C functions.
  • Page 5: Making Basic Measurements

    Making Basic Measurements Preparation and Caution Before Measurement : Observe the rules of Warnings and Cautions When connecting the test leads to the DUT (Device Under Test) connect the common (mA) test lead before connecting the live lead ; when removing the test leads removing the test live lead before removing the common test lead.

  • Page 6: Testing Diode

    Measuring Resistance / Continuity / Diode Measuring Resistance / Continuity / Diode Press the Blue button to select the measuring function. Testing Diode…

  • Page 7: Testing Continuity

    Testing Continuity The buzzer allows you to quick continuity tests without having to watch the display. The buzzer sounds when a short (< 30Ω) is defected. Measuring Capacitance…

  • Page 8
    Measuring Temperature °C / °F Measuring AC / DC Current…
  • Page 9: Measuring Insulation Resistance

    Measuring Insulation Resistance Select test voltage Press the Range button to select the test voltage (50V / 100V / 250V / 500V / 1000V) Lock test voltage Press the Hold button to lock the test voltage. Press the button again to cancel the lock mode. Make the reading stably Press the Blue button to make the reading stably, the “Smooth”…

  • Page 10
    Measuring Insulation Resistance Insulation tests should only be performed on dead circuits. Check the fuse before testing. To measure insulation resis- tance, follow the steps below. 1. Insert test probes in the “⊕ “ and “ “ input terminals. 2. Turn the rotary switch to Insulation position. 3.
  • Page 11: Display Hold

    Measuring Frequency for ACV, ACmV and ACmA The meter measures the frequency of a voltage or current signal by counting the number of times the signal crosses a threshold level each second. To measure frequency, follow the steps below. 1. Turn the rotary switch to V, mV or mA position. 2.

  • Page 12
    Display MAX / MIN / AVG The “MIN/MAX/AVG“ mode records minimum and maximum input values. When the inputs go below the recorded minimum value or above the recorded maximum value, the meter beeps and records the new value. MIN/MAX/AVG mode can also calculate an average of maximum and minimum.
  • Page 13
    Relative mode for Ω / In the Relative mode, the meter records the present reading as reference and the later reading will subtract it. To use the Relative mode, follow the steps below. 1. Turn the rotary switch to Ω or position.
  • Page 14
    Auto Test and Manual Test The meter has both “AutoTest “ mode and Manual Test mode. ˙In the Auto Test mode, the meter compares the reading of AC and DC, and the bigger reading appears on the display. The meter beeps when the AC/DC mode has change. ˙In the Manual Test mode, you override “AutoTest “…
  • Page 15: Auto Range And Manual Range

    Auto Range and Manual Range The meter has both Auto Range mode and Manual Range mode. ˙ In the Auto Range mode, the meter selects the range with the best resolution. ˙ In the Manual Range mode, you select the range yourself. When you turn the meter on, it defaults to Auto Range mode and the “Range”…

  • Page 16: Store And Recall

    Store and Recall You can store the reading on the display, and recall the reading on the display after. ˙To store the reading press the Store button. The data amount and “MEM” blink on the secondary display. ˙Each function has a separate memory space. Each memory space has the maximum 100 amounts.

  • Page 17: Auto Power Off

    Auto Power Off Wake-up the meter by switching rotor or pressing any button. Auto Backlight The backlight is automatically turned on at dark environment. BUZZER The meter beeps once for every valid key-press, and beeps twice for every invalid key-press. Power On Options Press button while turning the meter on from OFF position.

  • Page 18: Battery And Fuse Replacement

    Battery and Fuse Replacement Refer to the following figure to replace fuse and the batteries : Caution ˙Use only a fuse with the amperage, interrupt, voltage, and speed rating specified. ˙ Fuse rating : 440mA,1000V fast blow fuse. ˙ Replace the batteries as soon as the low batteries indicator «…

  • Page 19: Testing The Fuse

    Testing the fuse Test the fuse as described below. 1. Insert a test probe in the V, Ω, , Hz, °C input terminal. 2. Turn the rotary switch to Ω position, and press the Blue button to diode function. 3. Insert the probe in the mA input terminal. If the display reading is 0L, the fuse is bad and should be replaced.

  • Page 20: Specifications

    Specifications General Specifications Maximum voltage applied to any terminal : 1000 V ac rms or dc. Display : 10000 counts. Polarity Indication : Automatic, positive implied, negative indicated. Overrange Indication : OL Batteries Life : ALKALINE 80 hours. Insulation test : Tester can perform at least insulation tests with new alkaline batteries at room temperature.

  • Page 21: Electrical Specifications

    EMC : EN 61326-1 Shock vibration : Sinusoidal vibration per MIL-T- 28800E (5 ~ 55 Hz, 3g maximum). Drop Protection : 4 feet drop to hardwood on concrete floor. Indoor Use. Electrical Specifications Accuracy is ±(% reading + number of digits) at 23°C ± 5°C <…

  • Page 22
    CMRR / NMRR : (Common Mode Rejection Ratio) (Normal Mode Rejection Ratio) : CMRR > 60dB at DC, 50Hz / 60Hz : CMRR > 100dB at DC, 50Hz / 60Hz NMRR > 50dB at DC, 50Hz / 60Hz AC Conversion Type : AC conversions are ac-coupled, true rms responding, calibrated to the sine wave input.
  • Page 23
    Frequency Counter Sensitivity Sensitivity (RMS Sine Wave) Input Range Function (AC) 10Hz to 10kHz 10kHz to 100kHz 100.00mV 15.00mV 15.00mV ACmV 150.0mV 150.0mV 1000.0mV 1.500V 1.500V 10.000V 100.00V 1000.0V 15.00mA 100.00mA ACmA 30mA 400.0mA Minimun Pulse Width : >10us Overload Protection : 1000V AC rms or DC Resistance Measurement Function Range…
  • Page 24
    Capacitance Measurement Function Range Measuring Time Accuracy 10.000nF 0.7sec ±(1.2%+80d) 100.00nF 0.7sec ±(1.2%+20d) 1000.0nF 0.7sec ±(1.2%+2d) 10.000uF 0.7sec ±(1.2%+2d) Capacitance 100.00uF 0.7sec ±(1.2%+2d) 1000.0uF 3.75sec ±(1.2%+2d) 10.000mF 7.5sec ±(1.2%+20d) 40.00mF 7.5sec ±(1.2%+80d) Overload Protection : 1000V AC rms or DC Temperature Measurement Function Range…
  • Page 25
    Insulation Resistance Measurement Test Voltage Range Accuracy 2.000MΩ ±(1.5%+5d) 20.00MΩ ±(1.5%+5d) 55.0MΩ ±(1.5%+5d) 2.000MΩ ±(1.5%+5d) 100V 20.00MΩ ±(1.5%+5d) 110.0MΩ ±(1.5%+5d) 2.000MΩ ±(1.5%+5d) 20.00MΩ ±(1.5%+5d) 250V 200.0MΩ ±(1.5%+5d) 275MΩ ±(1.5%+5d) 2.000MΩ ±(1.5%+5d) 20.00MΩ ±(1.5%+5d) 500V 200.0MΩ ±(1.5%+5d) 550MΩ ±(1.5%+5d) 2.000MΩ ±(1.5%+5d) 20.00MΩ…
  • Page 26: Limited Warranty

    Limited Warranty This meter is warranted to the original purchaser against defects in material and workmanship for 2 years from the date of purchase. During this warranty period, Manufacturer will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction.

  • Page 27
    APPA TECHNOLOGY CORP. 9F.119-1 Pao-Zong Rd., Shin-Tien, Taipai, 23145, Taiwan, R.O.C. Tel : 886-2-29178820 Fax : 886-2-29170848 E-MAIL : info @appatech.com http ://www.appatech.com…

Мультиметры APPA 607 — инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.

Вы можете скачать инструкцию к APPA 607 по ссылке ниже, если не хотите ждать загрузки. Если остались вопросы, задайте их в комментариях после инструкции.

«Загружаем инструкцию», означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Часто задаваемые вопросы

Как посмотреть инструкцию к APPA 607?

Необходимо подождать полной загрузки инструкции в сером окне на данной странице или скачать кликнув по специальной кнопке.

Руководство на русском языке?

Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью

Как можно распечатать инструкцию?

Скачайте ее по специальной кнопке над формой чтения на ваше устройства и отправьте на печать.

инструкцияAPPA 607

Multimeter-Isolatiemeter

Multimètre- Mesureur d’isolement

Insulation Multimeter

APPA 607

Посмотреть инструкция для APPA 607 бесплатно. Руководство относится к категории мультиметры, 1 человек(а) дали ему среднюю оценку 7.3. Руководство доступно на следующих языках: английский. У вас есть вопрос о APPA 607 или вам нужна помощь? Задайте свой вопрос здесь

Нужна помощь?

У вас есть вопрос о APPA а ответа нет в руководстве? Задайте свой вопрос здесь Дай исчерпывающее описание проблемы и четко задайте свой вопрос. Чем детальнее описание проблемы или вопроса, тем легче будет другим пользователям APPA предоставить вам исчерпывающий ответ.

Количество вопросов: 0

Главная

Не можете найти ответ на свой вопрос в руководстве? Вы можете найти ответ на свой вопрос ниже, в разделе часто задаваемых вопросов о APPA 607.

Инструкция APPA 607 доступно в русский?

Не нашли свой вопрос? Задайте свой вопрос здесь

Посмотреть все APPA руководства Посмотреть все APPA Мультиметр руководства

APPA 607 - измеритель сопротивления изоляции


appa 607

appa 607

Характеристики:

Гарантия:

24 мес.

Максимальное испытательное напряжение, В:


1000

Максимальное измеряемое сопротивление:


22 ГОм

Коэффициент абсорбции DAR:


Нет

Коэффициент поляризации PI:


Нет

Интерфейс связи с компьютером:


нет

Смотреть все характеристики

APPA 607

APPA 607 — измеритель сопротивления изоляции

Описание APPA 607

  • Измерение сопротивления изоляции до 22 ГОм (± 1,5%), максимальное разрешение 50 кОм
  • Испытательное напряжение: 50/100/250/500/1000 В (постоянное, фиксированные значения)
  • Измерение напряжения до 1000 В (постоянное/переменное) , силы тока (мА), частоты, емкости, сопротивления и целостности цепи, температуры, испытание p-n переходов
  • Базовая погрешность ± 0,08% (DCV)
  • Разрешение: 0,1 мВ/ 0,1 Ом/ 0,1 мА/ 0,1 Гц/ 0,1 °С
  • Измерение ср. кв. значения сигналов произвольной формы (TRMS)
  • Автодетектирование напряжения (постоянное/переменное)
  • Зонд-пробник для дистанционного запуска теста изоляции Rиз
  • ЖК-индикатор (10.000), подсветка дисплея, 2 области индикации
  • Графическая линейная шкала (48 сегментов)
  • Защитная блокировка кнопок управления
  • Компенсация начального сопротивления (установка «0» показаний)
  • Автоудержание результата тестирования, авторазряд накопительного конденсатора
  • Регистрация Min/ Max/AVG значений, внутренняя память (запись/вывод)
  • Батарейное питание, индикация состояния источников питания, автовыключение
  • Надёжность, безопасность (кат. IV 600 В/кат. III 1000 В).


показать все
скрыть

Комплектация APPA 607

  • Измеритель сопротивления изоляции AliliA 607
  • Измерительные провода — 2 шт.
  • Испытательный пробник
  • Зажим «крокодил» — 2 шт.
  • Батареи питания — 4 шт.
  • Магнитный держатель
  • Защитный чехол
  • Руководство по эксплуатации

Документация для APPA 607

Отзывы на APPA 607

По данному товару нет отзывов.

Оставить отзыв

Спасибо за отзыв! Он будет опубликован после прохождения модерации.

Понравилась статья? Поделить с друзьями:
  • Крот активный для устранения засоров инструкция по применению
  • Гидроплазма инюшина инструкция по применению взрослым
  • Шерхан магикар автозапуск с брелка какие кнопки инструкция
  • Сканер выбытия честный знак инструкция по применению
  • Магния хлорид инструкция по применению капельница