Remote Mounting of LCP
®
VLT
HVAC Drive FC 102
Items Supplied
•
LCP cables with 2 M12 connectors (90° male connector and straight female connector). Cable lengths: 3 m, 5 m, and 10 m
(10 ft, 16 ft, 33 ft). See also Table 1.1.
•
Blind cover with M12 female connector.
•
Base plate with D-sub connector and M12 male connector.
•
Two gaskets and 1 nut for the D-sub connector.
•
Intermediate cover with the front cover.
•
Disassembly tool.
Length [m (ft)]
3 (10)
5 (16)
10 (33)
Table 1.1 Cable Ordering Numbers
More Items Required
•
Local control panel (LCP).
•
Four M4 self-tapping screws for mounting.
This instruction is valid for frequency converters that were ordered with the LCP. Front covers of frequency converters that
were ordered without LCPs do not have holes for mounting the blind covers.
Safety Instructions
For important information about safety precautions for installation, refer to the product-specific operating guide.
WARNING
DISCHARGE TIME
The frequency converter contains DC-link capacitors, which can remain charged even when the frequency converter is not
powered. High voltage can be present even when the warning LED indicator lights are off. Failure to wait the specified time
after power has been removed before performing service or repair work can result in death or serious injury.
•
Stop the motor.
•
Disconnect AC mains and remote DC-link power supplies, including battery back-ups, UPS, and DC-link connections to
other frequency converters.
•
Disconnect or lock PM motor.
•
Wait for the capacitors to discharge fully. The minimum duration of waiting time is specified in .
•
Before performing any service or repair work, use an appropriate voltage measuring device to make sure that the
capacitors are fully discharged.
Ordering number
134B5223
134B5224
134B5225
Danfoss A/S © 11/2017 All rights reserved.
MI05A202
User Interface
The display area is activated when the frequency converter
receives power from mains voltage, a DC bus terminal, or
an external 24 V DC supply.
The information displayed on the LCP can be customized
for user application.
•
Each display readout has a parameter associated
with it
•
Options are selected in the quick menu Q3-13
Display Settings
•
Display 2 has an alternate larger display option
•
The frequency converter status at the bottom line
of the display is generated automatically and is
not selectable
Status
0.0%
1.1
1.2
Off Remote Stop
2
Illustration 4.2 Display Readouts
Display
Parameter number
1.1
0-20
1.2
0-21
1.3
0-22
2
0-23
3
0-24
Table 4.1 Legend to Illustration 4.2
Phone: 800.894.0412 — Fax: 888.723.4773 — Web: www.ctiautomation.net — Email: info@ctiautomation.net
®
VLT
HVAC Drive Operating Instructions
1 (1)
0.00 A
0.00 kw
0.0Hz
2605kWh
3
1.3
Default setting
Reference %
Motor current
Power [kW]
Frequency
kWh counter
®
MG11AI02 — VLT
is a registered Danfoss trademark
4.1.3 Display Menu Keys
Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation, and viewing fault log data.
Quick
Status
Menu
Illustration 4.3 Menu Keys
Key
Function
Status
Shows operational information.
•
In Auto mode, press to toggle between
status read-out displays
•
Press repeatedly to scroll through each
status display
•
Press [Status] plus [
display brightness
•
The symbol in the upper right corner of the
display shows the direction of motor
rotation and which set-up is active. This is
not programmable.
Quick Menu
Allows access to programming parameters for
initial set up instructions and many detailed
application instructions.
•
Press to access Q2 Quick Setup for
sequenced instructions to program the basic
frequency controller set up
•
Follow the sequence of parameters as
presented for the function set up
Main Menu
Allows access to all programming parameters.
•
Press twice to access top-level index
•
Press once to return to the last location
accessed
•
Press to enter a parameter number for
direct access to that parameter
Alarm Log
Displays a list of current warnings, the last 10
alarms, and the maintenance log.
•
For details about the frequency converter
before it entered the alarm mode, select the
alarm number using the navigation keys
and press [OK].
Table 4.2 Function Description Menu Keys
Main
Alarm
Menu
Log
▲
▼
] or [
] to adjust the
33
4
4
LCP 102 Графическая локальная панель управления
- Мультиязычный дисплей
- Сообщения о статусе
- Быстрое меню для лёгкого ввода в действие
- Установка параметров и объяснение функционирования параметров
- Регулировка параметров
- Полная поддержка параметров и функция копирования
- Запись сообщений с предуреждениями
- Кнопка “Информация” – объясняет функцию выбранной позиции на дисплее
- Выбор функции пуска/останова вручную или автоматического режима
- Заказной номер
- Функция сброса
- График тенденций
Заказной номер |
VLT® HVAC Drive | VLT® AQUA Drive | VLT® AutomationDrive | |
FC 102 | FC 202 | FC 301 | FC 302 | |
130B1107 |
X | X | X | X |
Для покупки товара в нашем интернет-магазине выберите понравившийся товар и добавьте его в корзину. Далее перейдите в Корзину и нажмите на «Оформить заказ» или «Быстрый заказ».
Когда оформляете быстрый заказ, напишите ФИО, телефон и e-mail. Вам перезвонит менеджер и уточнит условия заказа. По результатам разговора вам придет подтверждение оформления товара на почту или через СМС. Теперь останется только ждать доставки и радоваться новой покупке.
Оформление заказа в стандартном режиме выглядит следующим образом. Заполняете полностью форму по последовательным этапам: адрес, способ доставки, оплаты, данные о себе. Советуем в комментарии к заказу написать информацию, которая поможет курьеру вас найти. Нажмите кнопку «Оформить заказ».
Оплачивайте покупки удобным способом. В интернет-магазине доступно 3 варианта оплаты:
- Наличные при самовывозе или доставке курьером. Специалист свяжется с вами в день доставки, чтобы уточнить время и заранее подготовить сдачу с любой купюры. Вы подписываете товаросопроводительные документы, вносите денежные средства, получаете товар и чек.
- Безналичный расчет при самовывозе или оформлении в интернет-магазине: карты Visa и MasterCard. Чтобы оплатить покупку, система перенаправит вас на сервер системы ASSIST. Здесь нужно ввести номер карты, срок действия и имя держателя.
- Электронные системы при онлайн-заказе: PayPal, WebMoney и Яндекс.Деньги. Для совершения покупки система перенаправит вас на страницу платежного сервиса. Здесь необходимо заполнить форму по инструкции.
Экономьте время на получении заказа. В интернет-магазине доступно 4 варианта доставки:
- Курьерская доставка работает с 9.00 до 19.00. Когда товар поступит на склад, курьерская служба свяжется для уточнения деталей. Специалист предложит выбрать удобное время доставки и уточнит адрес. Осмотрите упаковку на целостность и соответствие указанной комплектации.
- Самовывоз из магазина. Список торговых точек для выбора появится в корзине. Когда заказ поступит на склад, вам придет уведомление. Для получения заказа обратитесь к сотруднику в кассовой зоне и назовите номер.
- Постамат. Когда заказ поступит на точку, на ваш телефон или e-mail придет уникальный код. Заказ нужно оплатить в терминале постамата. Срок хранения — 3 дня.
- Почтовая доставка через почту России. Когда заказ придет в отделение, на ваш адрес придет извещение о посылке. Перед оплатой вы можете оценить состояние коробки: вес, целостность. Вскрывать коробку самостоятельно вы можете только после оплаты заказа. Один заказ может содержать не больше 10 позиций и его стоимость не должна превышать 100 000 р.
Дополнительная вкладка, для размещения информации о магазине, доставке или любого другого важного контента. Поможет вам ответить на интересующие покупателя вопросы и развеять его сомнения в покупке. Используйте её по своему усмотрению.
Вы можете убрать её или вернуть обратно, изменив одну галочку в настройках компонента. Очень удобно.