Fluke 5502e руководство по эксплуатации

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

5502E

Multi-Product Calibrator

Getting Started

PN 4238530

November 2012

© 2012 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.

All product names are trademarks of their respective companies.

loading

Related Manuals for Fluke 5502E

Summary of Contents for Fluke 5502E

  • Page 1
    5502E Multi-Product Calibrator Getting Started PN 4238530 November 2012 © 2012 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
  • Page 2
    Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price.
  • Page 3
    OPERATOR SAFETY SUMMARY WARNING HIGH VOLTAGE is used in the operation of this equipment LETHAL VOLTAGE may be present on the terminals, observe all safety precautions! To prevent electrical shock hazard, the operator should not electrically contact the output HI or sense HI terminals or circuits connected to these terminals. During operation, lethal voltages of up to 1020 V ac or dc may be present on these terminals.
  • Page 5: Table Of Contents

    Connect to Line Power ………………8 Select Line Frequency ………………8 Placement ………………….10 Airflow Considerations ………………11 Instruction Manuals ………………. 11 5502E Getting Started Manual …………..11 5502A Operators Manual …………….11 General Specifications ………………12 Detailed Specifications ………………13 DC Voltage ………………..13 DC Current ………………..

  • Page 6
    5502E Getting Started AC Voltage, Triangle Wave Characteristics (typical) ……..24 AC Current (Non-Sine Wave) …………… 24 AC Current (Non-Sine Wave) (cont.) …………25 AC Current, Square Wave Characteristics (typical) ……..25 AC Current, Triangle Wave Characteristics (typical) ……..25…
  • Page 7
    Title Page Symbols ……………………4 Standard Equipment ………………..7 Mains-Power Cord Types Available from Fluke Calibration …….. 10 Verification Tests for DC Voltage (Normal) …………26 Verification Tests for DC Current (AUX) …………. 27 Verification Tests for Resistance …………….28 Verification Tests for AC Voltage (Normal) …………
  • Page 8
    5502E Getting Started…
  • Page 9
    List of Figures Figure Title Page 5502E Multi-Product Calibrator …………….2 RS-232 Remote Connection ………………. 6 Access the Fuse and Select Line Voltage …………… 9 Mains-Power Cord Types Available from Fluke Calibration …….. 10 Allowable Duration of Current >11 A …………..14…
  • Page 10
    5502E Getting Started…
  • Page 11: Getting Started

    The 300 MHz and 600 MHz options are not compatible with the 5502E. The 5502E does not have SCOPE and TRIG OUT terminals. The SCOPE and TRIG OUT buttons are on the front panel of the 5502E, but they are non-functional and beep when pushed.

  • Page 12
    488.1-1987 and 488.2-1987. • A EIA Standard RS-232 serial data interface to print, show, or move internally stored calibration constants, and for remote control of the 5502E. • A pass-through RS-232 serial data interface to send data to the Unit Under Test…
  • Page 13: Safety Information

    Multi-Product Calibrator Safety Information Safety Information In this manual, A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test. Warning To prevent possible electrical shock, fire, or personal injury: •…

  • Page 14: Symbols

    WEEE Directive Annex I, this product is classed as category 9 «Monitoring and Control Instrumentation” product. Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information. Risk of Danger. Important  …

  • Page 15: Contact Fluke Calibration

    • Brazil: +55-11-3759-7600 • Anywhere in the world: +1-425-446-6110 To see product information and download the latest manual supplements, visit Fluke Calibration’s website at www.flukecal.com. To register your product, visit http://flukecal.com/register-product. Overload Protection The Calibrator supplies reverse-power protection, fast output disconnection, and/or fuse protection on the output terminals for all functions.

  • Page 16: Remote Operation (Rs-232)

    5502E Getting Started Remote Operation (RS-232) There are two rear-panel serial data RS-232 ports: SERIAL 1 FROM HOST, and SERIAL 2 TO UUT (see Figure 2). Each port is dedicated to serial-data communications to operate and control the Product during calibration procedures. For complete information on remote operation, see Chapter 5 of the Operators Manual.

  • Page 17: Unpack And Inspection

    Calibration Service Center (see “Contact Fluke Calibration”). A performance test is in the “Maintenance” section of Chapter 7 in the Operators Manual. If you ship the calibrator to Fluke Calibration, use the initial container. If it is not available, you can get a new container from Fluke Calibration with the Calibrator model and serial number.

  • Page 18: Connect To Line Power

    If it is necessary to use a different type, refer to Table 3 and Figure 4 for a list and illustration of the line-power plug types available from Fluke Calibration. After you make sure that the line voltage selection is set correctly and that the correct fuse for that line voltage is installed, connect the calibrator to a correctly-grounded three-prong outlet.

  • Page 19
    Multi-Product Calibrator Select Line Frequency Line Voltage Indicator Changing Line Fuse Changing Line Voltage gjh004.eps Figure 3. Access the Fuse and Select Line Voltage…
  • Page 20: Placement

    5502E Getting Started Table 3. Mains-Power Cord Types Available from Fluke Calibration Fluke Calibration Option Type Voltage/Current Number North America 120 V/15 A LC-1 North America 240 V/15 A LC-2 Universal Euro 220 V/15 A LC-3 United Kingdom 240 V/13 A…

  • Page 21: Airflow Considerations

    • 5502E Getting Started (PN 4238530) One of each manual above comes with the instrument. Refer to the Fluke Calibration Catalog or speak to a Fluke Calibration sales representative (see “Contact Fluke Calibration”) if more printed copies are necessary. The manuals are also available on the Fluke Calibration website.

  • Page 22: General Specifications

    The following tables list the 5502E specifications. All specifications are valid after allowing a warm-up period of 30 minutes, or twice the time the 5502E has been turned off. (For example, if the 5502E has been turned off for 5 minutes, the warm-up period is 10 minutes.) All specifications apply for the temperature and time period indicated.

  • Page 23: Detailed Specifications

    Weight (without options) ……..22 kg (49 lb) Absolute Uncertainty Definition ……The 5502E specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. You do not need to add anything to determine the total specification of the 5502E for the temperature range indicated.

  • Page 24: Dc Current

    Formula 60-T-I minutes any 60 minute period where T is the temperature in °C (room temperature is about 23 °C) and I is the output current in amperes. For example, 17 A, at 23 °C could be provided for 60-23-17 = 20 minutes each hour. When the 5502E is outputting currents between 5 and 11 amps for long periods, the internal self-heating reduces the duty cycle.

  • Page 25: Resistance

    Multi-Product Calibrator Detailed Specifications Resistance Absolute Uncertainty, tcal ±5 °C ±(% of output + floor) Resolution Allowable Current Floor (Ω) Time and temp since ohms Range % of output (Ω) zero cal 90 Day 1 Year 12 hrs ±1 °C 7 days ±5 °C 0 to 10.999 Ω…

  • Page 26: Ac Voltage (Sine Wave)

    5502E Getting Started AC Voltage (Sine Wave) Absolute Uncertainty, tcal Max Distortion and ±5 °C ±(% of output + μV) Noise 10 Hz to Range Frequency Resolution Max Burden 5 MHz Bandwidth ±(% of output + 90 Day 1 Year…

  • Page 27: Ac Current (Sine Wave)

    60-T-I minutes any 60 minute period where T is the temperature in °C (room temperature is about 23 °C) and I is the output current in amps. For example, 17 A, at 23 °C could be provided for 60-17-23 = 20 minutes each hour. When the 5502E is outputting currents between 5 and 11 amps for long periods, the internal self-heating reduces the duty cycle.

  • Page 28: Ac Current (Sine Wave) (Cont.)

    60-T-I minutes any 60 minute period where T is the temperature in °C (room temperature is about 23 °C) and I is the output current in amps. For example, 17 A, at 23 °C could be provided for 60-17-23 = 20 minutes each hour. When the 5502E is outputting currents between 5 and 11 amps for long periods, the internal self-heating reduces the duty cycle.

  • Page 29: Capacitance

    Multi-Product Calibrator Detailed Specifications Capacitance Absolute Uncertainty, tcal ±5 °C Allowed Frequency or Charge-Discharge Rate [1] [2] [3] ±(% of output + floor) Range Resolution Min and Max to Typical Max for Typical Max for 90 Day 1 Year Meet <0.5 % Error <1 % Error Specification…

  • Page 30: Temperature Calibration (Thermocouple)

    5502E Getting Started Temperature Calibration (Thermocouple) Absolute Uncertainty Absolute Uncertainty Source/Measure tcal ±5 °C ± Source/Measure tcal TC Type Range °C Range °C Type °C ±5 °C ± °C 90 Day 1 Year 90 Day 1 Year 600 to 800 0.42…

  • Page 31: Temperature Calibration (Rtd)

    The subsequent paragraphs provide additional specifications for the 5502E Calibrator ac voltage and ac current functions. These specifications are valid after allowing a warm-up period of 30 minutes, or twice the time the 5502E has been turned off. All extended range specifications are based on performing the internal zero-cal function at weekly intervals, or when the ambient temperature changes by more than 5 °C.

  • Page 32: Ac Voltage (Sine Wave) Extended Bandwidth

    5502E Getting Started AC Voltage (Sine Wave) Extended Bandwidth 1-Year Absolute Uncertainty Range Frequency Max Voltage Resolution tcal ±5 °C Normal Channel (Single Output Mode) 1.0 to 33 mV Two digits, e.g., 25 mV ±(5.0 % of output 34 to 330 mV 0.01 to 9.99 Hz…

  • Page 33: Ac Voltage (Non-Sine Wave) (Cont.)

    Multi-Product Calibrator Additional Specifications AC Voltage (Non-Sine Wave) (cont.) 1-Year Absolute Uncertainty, tcal Square Wave Frequency Max Voltage Resolution ±5 °C, ±(% of output + % of range) Range (p-p) Normal Channel (Single Output Mode) 0.01 to 10 Hz 5.0 + 0.5 Two digits on each range 10 to 45 Hz 0.25 + 0.5…

  • Page 34: Ac Voltage, Square Wave Characteristics

    5502E Getting Started AC Voltage, Square Wave Characteristics Risetime @ Overshoot Settling Time @ 1 kHz @ 1 kHz Duty Cycle Range Duty Cycle Uncertainty 1 kHz Typical Typical Typical ±(0.02 % of period + 100 ns), 50 % duty cycle <10 μs to 1 % of…

  • Page 35: Ac Current (Non-Sine Wave) (Cont.)

    Multi-Product Calibrator Additional Specifications AC Current (Non-Sine Wave) (cont.) 1-Year Absolute Uncertainty tcal ±5 °C Max Current Square Wave Range p-p Frequency ±(% of output + % of range) Resolution 10 to 45 Hz 0.25 + 0.5 0.047 to 0.65999 mA 45 Hz to 1 kHz 0.25 + 0.25 Six digits…

  • Page 36: Performance Tests

    The limits were calculated by adding or subtracting the 90-day specification from the output value. There is no built-in factor for measurement uncertainty. These performance tests replace those found in the 5502A Operators Manual and only apply to the 5502E. Table 4. Verification Tests for DC Voltage (Normal)

  • Page 37: Verification Tests For Dc Current (Aux)

    Multi-Product Calibrator Performance Tests Table 5. Verification Tests for DC Current (AUX) Range Output Lower Limit Upper Limit 329.999 μA 0.000 μA -0.020 μA 0.020 μA 329.999 μA 190.000 μA 189.957 μA 190.043 μA 329.999 μA -190.000 μA -190.043 μA -189.957 μA 329.999 μA 329.000 μA…

  • Page 38: Verification Tests For Resistance

    5502E Getting Started Table 6. Verification Tests for Resistance Range Output Lower Limit Upper Limit 10.999 Ω 0.000 Ω -0.0010 Ω 0.0010 Ω 10.999 Ω 2.000 Ω 1.9989 Ω 2.0011 Ω 10.999 Ω 10.900 Ω 10.8980 Ω 10.9019 Ω 32.999 Ω…

  • Page 39
    Multi-Product Calibrator Performance Tests Table 6. Verification Tests for Resistance (cont.) Range Output Lower Limit Upper Limit 109.999 kΩ 33.000 kΩ 32.9971 kΩ 33.0028 kΩ 109.999 kΩ 109.000 kΩ 108.9910 kΩ 109.0089 kΩ 329.999 kΩ 119.000 kΩ 118.9872 kΩ 119.0127 kΩ 329.999 kΩ…
  • Page 40: Verification Tests For Ac Voltage (Normal)

    5502E Getting Started Table 7. Verification Tests for AC Voltage (Normal) Range Output Frequency Lower Limit Upper Limit 32.999 mV 3.000 mV 45 Hz 2.977 mV 3.022 mV 32.999 mV 3.000 mV 10 kHz 2.977 mV 3.022 mV 32.999 mV 30.000 mV…

  • Page 41
    Multi-Product Calibrator Performance Tests Table 7. Verification Tests for AC Voltage (Normal) (cont.) Range Output Frequency Lower Limit Upper Limit 3.29999 V 3.00000 V 100 kHz 2.99437 V 3.00563V 3.29999 V 3.00000 V 450 kHz 2.98659 V 3.01340 V 3.29999 V 3.29000 V 1 MHz 2.250 V…
  • Page 42: Verification Tests For Ac Current

    5502E Getting Started Table 8. Verification Tests for AC Current Range Output Frequency Lower Limit Upper Limit 329.99 μA 33.00 μA 32.87 μA 33.13 μA 1 kHz 329.99 μA 33.00 μA 32.60 μA 33.40 μA 10 kHz 329.99 μA 33.00 μA 32.20 μA…

  • Page 43
    Multi-Product Calibrator Performance Tests Table 8. Verification Tests for AC Current (cont.) Range Output Frequency Lower Limit Upper Limit 32.999 mA 19.0000 mA 30 kHz 18.935 mA 19.065 mA 32.999 mA 32.9000 mA 10 Hz 32.849 mA 32.951 mA 32.999 mA 32.9000 mA 1 kHz 32.886 mA…
  • Page 44
    5502E Getting Started Table 8. Verification Tests for AC Current (cont.) Range Output Frequency Lower Limit Upper Limit 2.99999 A 2.99000 A 10 kHz 2.92520 A 3.05480 A 20.5000 A 3.3000 A 500 Hz 3.2954 A 3.3046 A 20.5000 A 3.3000 A…
  • Page 45: Verification Tests For Capacitance

    Multi-Product Calibrator Performance Tests Table 9. Verification Tests for Capacitance Test Frequency Range Output Lower Limit Upper Limit or Current 0.3999 nF 0.2200 nF 5 kHz 0.2192 nF 0.2308 nF 0.3999 nF 0.3500 nF 1 kHz 0.3387 nF 0.3613 nF 1.0999 nF 0.4800 nF 1 kHz…

  • Page 46: Verification Tests For Thermocouple Simulation

    5502E Getting Started Table 9. Verification Tests for Capacitance (cont.) Test Frequency Range Output Lower Limit Upper Limit or Current 540 μA dc 3.299 mF 2.000 mF 1.9902 mF 2.0098 mF 800 μA dc 3.299 mF 3.000 mF 2.9868 mF 3.0132 mF…

  • Page 47: Verification Tests For Frequency

    Multi-Product Calibrator Performance Tests Table 12. Verification Tests for Frequency Range, Normal Output, Normal, V Frequency Lower Limit [1] Upper Limit [1] Output, V 119.00 Hz 118.99602 Hz 119.00398 Hz 120.0 Hz 119.99600 Hz 120.00400 Hz 3.29999 3.00000 1000.0 Hz 999.974000 Hz 1000.026000 Hz 100.00 kHz…

  • Page 48
    5502E Getting Started…

Table of Contents for Fluke 5502E:

  • Multi-Product Calibrator Detailed Specifications 19 Capacitance Range Absolute Uncertainty, tcal ±5 °C ±(% of output + floor) [1] [2] [3] Resolution Allowed Frequency or Charge-Discharge Rate 90 Day 1 Year Min and Max to Meet Specification Typical Max for <0.5 % Error Typical Max for <1 % Error 220.0 to 399.9 pF 0.38 + 0.01 nF 0.5 + 0.01 nF 0.1 pF 10 Hz to 10 kHz 20 kHz 40 kHz 0.4 to 1.0999 nF 0.38 + 0.01 nF

  • OPERATOR SAFETY SUMMARY WARNING HIGH VOLTAGE is used in the operation of this equipment LETHAL VOLTAGE may be present on the terminals, observe all safety precautions! To prevent electrical shock hazard, the operator should not electrically contact the output HI or sense HI terminals or circuits connected to these terminals. During operation, lethal voltages of up to 1020 V ac or dc may be present

  • 5502E Getting Started 22 AC Voltage (Sine Wave) Extended Bandwidth Range Frequency 1- Y ear Absolute Uncertainty tcal ±5 °C Max Voltage Resolution Normal Channel (Single Output Mode) 1.0 to 33 mV 0.01 to 9.99 Hz ±(5.0 % of output +0.5 % of range) Two digits, e.g., 25 mV 34 to 330 mV Three digits 0.4 to 33 V Two digits 0.3 to 3.3 V 500.1 kHz to 1 MHz -10 dB at 1 MHz, typical Two digits 1.001 to 2 MHz -31 dB at 2 MHz, typical AC Voltage (Non-Sine Wave) Triangle Wave & Truncated Sine Range, p-p [1] Frequency 1-Year Absolute Uncertaint

  • 5502E Getting Started 4 This Calibrator complies with: • ANSI/ISA-61010-1 (82.02.01) • CAN/CSA C22.2 No. 61010-1-04 • ANSI/UL 61010-1:2004 • EN 61010-1:2001 • ANSI/IEEE Standards 488.1-1987 and 488.2-1987. Symbols used in this manual and on the Product are in Table 1. Table 1. Symbols Symbol Description Symbol Description CAT I IEC Measurement Category I – CAT I is for measurements not directly connected to mains. Maximum transient Overvoltage is as specified by

  • i Table of Contents Title Page Getting Started …………………………………………………………………………………… 1 Introduction ………………………………………………………………………………………….. 1 Safety Information ………………………………………………………………………………… 3 Contact Fluke Calibration ………………………………………………………………………. 5 Over

  • Multi-Product Calibrator Performance Tests 37 Table 12. Verification Tests for Frequency Range, Normal Output, V Output, Normal, V Frequency Lower Limit [1] Upper Limit [1] 3.29999 3.00000 119.00 Hz 118.99602 Hz 119.00398 Hz 120.0 Hz 119.99600 Hz 120.00400 Hz 1000.0 Hz 999.974000 Hz 1000.026000 Hz 100.00 kHz 99.99750000 Hz 100.00250000 Hz [1] Frequency accuracy is specified for 1 year.

  • Multi-Product Calibrator Additional Specifications 25 AC Current (Non-Sine Wave) (cont.) Square Wave Range p-p Frequency 1-Year Absolute Uncertainty tcal ±5 °C ±(% of output + % of range) Max Current Resolution 0.047 to 0.65999 mA [1] 10 to 45 Hz 0.25 + 0.5 Six digits 45 Hz to 1 kHz 0.25 + 0.25 1 to 10 kHz 10 + 2 0.66 to 6.59999 mA [1] 10 to 45 Hz 0.25 + 0.5 Six digits 45 Hz to 1 kHz 0.25 + 0.25 1 to 10 kHz 10 + 2 6.6 to 65.9999 mA [1]

  • 5502E Getting Started 18 AC Current (Sine Wave) (cont.) Range Frequency Absolute Uncertainty, tcal ±5 °C ±(% of output + μA) Max Distortion and Noise 10 Hz to 100 kHz BW ±(% of output + floor) Max Inductive Load 90 Day 1 Year LCOMP On 29 to 329.99 μA 10 to 100 Hz 0.20 + 0.2 0.25 + 0.2 0.1 + 1.0 μA 400 μH 100 Hz to 1 kHz 0.50 + 0.5 0.60 + 0.5 0.05 + 1.0 μA 330 μA to 3.29999 mA 10 to 100 Hz 0.20 + 0.3 0.25 + 0.3 0.15 + 1.5 μA

  • 5502E Getting Started 2 0 • 123 4 5 6 7 8 9 ENTER M k m V Hz / + F OPR STBY EARTH TRIG OUT SCOPE ME NU PREV SHIFT RESET CE SETUP REF NEW TC MEAS ¡F n p W dBm sec ¡C POWER A MULT x DIV CAL ZERO FIELD EDIT 5502E CALIBRATOR gvw001.eps Figure 1. 5502E Multi-Product Calibrator Calibrator features include: • Automatic meter error calculation, with reference values that you can select. •  and  keys that change the output value to predetermined values f

  • Multi-Product Calibrator Detailed Specifications 17 AC Current (Sine Wave) Range Frequency Absolute Uncertainty, tcal ±5 °C ±(% of output + μA) Compliance adder ±(μA/V) Max Distortion and Noise 10 Hz to 100 kHz BW ±(% of output + floor) Max Inductive Load μH 90 Day 1 Year LCOMP Off 29 to 329.99 μA 10 to 20 Hz 0.16 + 0.1 0.2 + 0.1 0.05 0.15 + 0.5 μA 200 20 to 45 Hz 0.12 + 0.1 0.15 + 0.1 0.05 0.10 + 0.5 μA 45 Hz to 1 kHz 0.1 + 0.1 0.125 +

  • 5502E Getting Started 6 Remote Operation (RS-232) There are two rear-panel serial data RS-232 ports: SERIAL 1 FROM HOST, and SERIAL 2 TO UUT (see Figure 2). Each port is dedicated to serial-data communications to operate and control the Product during calibration procedures. For complete information on remote operation, see Chapter 5 of the Operators Manual. The SERIAL 1 FROM HOST serial data port connects a host terminal or personal computer (PC) to the Calibra

  • Multi-Product Calibrator Performance Tests 33 Table 8. Verification Tests for AC Current (cont.) Range Output Frequency Lower Limit Upper Limit 32.999 mA 19.0000 mA 30 kHz 18.935 mA 19.065 mA 32.999 mA 32.9000 mA 10 Hz 32.849 mA 32.951 mA 32.999 mA 32.9000 mA 1 kHz 32.886 mA 32.914 mA 32.999 mA 32.9000 mA 5 kHz 32.877 mA 32.923 mA 32.999 mA 32.9000 mA 10 kHz 32.844 mA 32.956 mA 32.999 mA 32.9000 mA 30 kHz

  • Multi-Product Calibrator Detailed Specifications 15 Resistance Range [1] Absolute Uncertainty, tcal ±5 °C ±(% of output + floor) [2] Resolution (Ω) Allowable Current [3] (A) % of output Floor (Ω) Time and temp since ohms zero cal 90 Day 1 Year 12 hrs ±1 °C 7 days ±5 °C 0 to 10.999 Ω 0.009 0.012 0.001 0. 01 0.001 1 mA to 125 mA 11 to 32.999 Ω 0.009 0.012 0.0015 0.015 0.001 1 mA to 125 mA 33 to 109.999 Ω

  • PN 4238530 November 2012 © 2012 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. 5502E Multi-Product Calibrator Getting Started

  • 5502E Getting Started 28 Table 6. Verification Tests for Resistance Range Output Lower Limit Upper Limit 10.999 Ω 0.000 Ω -0.0010 Ω 0.0010 Ω 10.999 Ω 2.000 Ω 1.9989 Ω 2.0011 Ω 10.999 Ω 10.900 Ω 10.8980 Ω 10.9019 Ω 32.999 Ω 11.900 Ω 11.8974 Ω 11.9025 Ω 32.999 Ω 19.000 Ω 18.9967 Ω 19.0032 Ω 32.999 Ω 30.000 Ω 29.9958 Ω 30.0042 Ω 109.999 Ω 33.000 Ω 32.9962 Ω 33.0037 Ω 109.999 Ω 109.000 Ω 108.9909 Ω 109.0090 Ω 329.999 Ω 119.000 Ω 118.9896 Ω 119.0103 Ω 329.999 Ω 190.000 Ω 189.9847 Ω 190.0153 Ω 329.999 Ω 300.

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of Fluke 5502E device using right now.

Калибраторы многофункциональные Fluke 5502E и Fluke 5502A со встраиваемыми модулями поверки осциллографов 300 МГц, 600 МГц зарегистрированы в Госреестре средств измерений РФ под № 55804-13 и имеют Свидетельство об утверждении типа СИ №53341 (срок действия до 12 октября 2023 г.).

Особенности:

  • Калибровка / поверка широкого спектра оборудования для электрических измерений
  • Надежная защита цепей предотвращает ошибки оператора
  • Прочный переносной футляр со встроенными ручками и колесами и съемные стенки для доступа к передней и задней панелям прибора.
  • Выходное значение тока до 120 А при одновременном использовании с опциональным усилителем тока Fluke 52120A, управляемым напряжением
  • Эргономичные прочные ручки облегчают транспортировку прибора
  • Доступная цена

Калибратор Fluke 5502А позволяет решить распространенные задачи калибровки / поверки, включая:

  • портативные и настольные аналоговые и цифровые мультиметры с количеством разрядов до 4,5;
  • токовые клещи;
  • щитовые измерители;
  • электронные термометры;
  • диаграммные самописцы;
  • осциллографы (при наличии соответствующей опции);
  • координатные самописцы;
  • регистраторы данных.

Универсальный калибратор Fluke 5502А подходит для использования с наиболее распространенными цифровыми мультиметрами с количеством разрядов 3,5 и 4,5 и другими устройствами. Конструкция прибора позволяет удобно транспортировать его и проводить калибровку на рабочем месте. Модель 5502A можно полностью автоматизировать с помощью ПО MET/CAL® Plus для управления процессом калибровки. Это идеальный калибратор для профессионалов в области метрологии, которым требуется решение для калибровки электрических параметров с низкой или средней точностью.

Калибратор Fluke 5502A является источником постоянного напряжения и тока, переменного напряжения и тока с несколькими формами сигнала и гармониками, имеет два параллельных выхода по напряжению или напряжению и току для имитации источников постоянного и переменного тока с управлением фазой, сопротивлением, емкостью, термопарами и термометрами сопротивления. Многофункциональный калибратор Fluke 5502А может также использоваться с термопарами и моделями термопар. Две опции предоставляют дополнительную возможность калибровки осциллографов с частотой до 300 МГц или до 600 МГц. Также с помощью усилителя тока Fluke 52120А, управляемого напряжением, и токовых катушек Fluke 5500А/COIL можно калибровать токоизмерительные клещи, рассчитанные на 6000 А.

Более подробная информация по Fluke 5502A представлена в брошюре, которую можно скачать по ссылке: Брошюра Fluke 5502A.pdf (2.6 Mb).

Компания FLUKE предлагает экономичную версию многофункционального калибратора Fluke 5502Е, позволяющую сэкономить до 50% от стоимости базовой модели Fluke 5502A. Отличительной особенностью данной модификации является невозможность дооснащения калибратора такими дополнительными опциями, как:

  • Калибровка / поверка Осциллографов
  • Калибровка / поверка Измерителей мощности постоянного и переменного тока
  • Калибровка / поверка Анализаторов качества электрической энергии и анализаторов гармоник

С подробными техническими характеристиками Вы можете познакомиться, скачав файл размером 2 Mb по ссылке: TTX Fluke 5502E.

Fluke 5502A и Fluke 5502Е Технические характеристики Многофункциональных калибраторов

Fluke 5502A и Fluke 5502E Модели многофункциональных калибраторов

Номер в Госреестре СИ 55804-13
Fluke 5502Е экономичная версия многофункционального калибратора Fluke 5502A, позволяющую сэкономить до 50% от стоимости базовой модели.
Отличительной особенностью данной модификации являются отсутствие следующих функций:
· Функции питания постоянного и переменного тока (одновременный выходной сигнал по напряжению и току);
· Функция двойного напряжения (одновременный выходной сигнал по напряжению/напряжению);
· Функция «Фаза»;
· Функция «Гармоники».
Разъемы опорного сигнала 10 МГц IN (вход) и OUT (выход) на задней панели не функциональные. Клеммы предназначены только для обслуживания.
У модели Fluke 5502E нет клемм SCOPE и TRIG OUT на передней панели.
Опции калибровки / поверки осциллографов полосой 300 МГц и 600 МГц несовместимы с моделью Fluke 5502E.

Госреестр СИ №55804-13

Fluke 5502А полная версия многофункционального калибратора Fluke.

Отличительной особенностью данной модификации являются наличие следующих функций:

· Функции питания постоянного и переменного тока (одновременный выходной сигнал по напряжению и току);

· Функция двойного напряжения (одновременный выходной сигнал по напряжению/напряжению);

· Функция «Фаза»;

· Функция «Гармоники».

Разъемы опорного сигнала 10 МГц IN (вход) и OUT (выход) на задней панели функциональные.

Номер в Госреестре СИ №55804-13

Fluke 550А/3 полная версия многофункционального калибратора Fluke 5502A со встроенной опцией поверки осциллографов до 300 МГц.

Отличительной особенностью данной модификации являются наличие встроенной опции SC300, предназначенной для поверки и калибровки аналоговых и цифровых осциллографов полосой до 300 МГц.

Разъемы опорного сигнала 10 МГц IN (вход) и OUT (выход) на задней панели.

Наличие клемм SCOPE и TRIG OUT на передней панели.

Номер в Госреестре СИ №55804-13

Fluke 550А/6 полная версия многофункционального калибратора Fluke 5502A со встроенной опцией поверки осциллографов до 600 МГц.

Отличительной особенностью данной модификации являются наличие встроенной опции SC600, предназначенной для поверки и калибровки аналоговых и цифровых осциллографов полосой до 600 МГц.

Разъемы опорного сигнала 10 МГц IN (вход) и OUT (выход) на задней панели.

Наличие клемм SCOPE и TRIG OUT на передней панели.

Номер в Госреестре №61033-15
Усилитель тока, управляемый напряжением, Fluke 52120A обеспечивает на выходе постоянный ток до 100 А и переменный ток до 120 А частотой до 10 КГц с точностью до 140 миллионных долей.
Принимает входные сигналы постоянного или переменного тока от любого калибратора, генератора сигналов или источника питания: напряжение до 2 В или тока до 200 мА.
Применение опциональных токовых катушек позволяет создавать выходной ток до 3 000 А или до 6 000 А.

Прочный кейс 5522A/CARRYCASE предназначен для транспортировки калибраторов Fluke 5502Е, 5502А и Fluke 5522А с любыми встроенными опциями.
Основные особенности:

  • Прочность
  • Герметичность
  • Удобство транспортировки благодаря колесам и выдвижной ручке
  • Наличие съемных передней и задней панелей для обеспечения работы с калибратором в полевых условиях без извлечения из кейса.

Прочный переносной кейс 55XX/CASE с колесами
Прочный кейс для транспортировки калибраторов Fluke 5080A, Fluke 5502E, 5502A и Fluke 5522A с любыми встроенными опциями.
Основные особенности:

  • Прочность
  • Герметичность
  • Удобство транспортировки благодаря колесам и выдвижной ручке.

5500A/LEADS Термопара и набор тестовых проводов в сумке / Leads Set for 5500A

Госреестр СИ РФ №61596-15
Катушка для калибровки бесконтактных измерителей тока Fluke 5500А/COIL имеет 50 витков и предназначена для поверки и калибровки измерительных токовых клещей и других бесконтактных измерителей тока.

Опция Fluke 9100-200 представляет собой 2 токовых катушки на 10 и на 50 витков в одном корпусе и предназначена для калибровки измерительных токоизмерительных клещей и других бесконтактных измерителей тока.
Не внесена в Госреестр СИ РФ.

Y8021 IEEE-488 Shielded Interface Cable, 1 m / Экранированый интерфейсный кабель IEEE-488 длина 1м

Y8022 IEEE-488 Shielded Interface Cable, 2 m / Экранированый интерфейсный кабель IEEE-488 длина 2м

ПО MET/CAL/TEAMXP компании Fluke Calibration состоит из двух приложений: MET/CAL® и MET/TEAM®.
Основные задачи ПО MET/CAL®:

  • Автоматизация калибровки/поверки всех типов контрольно-измерительных приборов и оборудования, в том числе приборов постоянного тока и низких частот, радиочастотных и СВЧ приборов;
  • Создание, редактирование, тестирование и документирование процедур калибровки;
  • Настройка и составление отчетов для параметров погрешности измерений, занесение данных поверки в протокол.

ПО MET/TEAM® предназначено для организации процесса калибровки и управления парком контрольно-измерительного оборудования. Его основные особенности:

  • Отслеживание информации о парке оборудования, включая историю калибровок и технического состояния, список пользователей и заказчиков.
  • Анализ и составления отчета о парке оборудования, изготовление фирменных печатных сертификатов и протоколов.
  • Импорт данных о парке приборов и результатов калибровки в ПО MET/CAL
  • Обеспечения соответствия требованиям стандартов качества, например, ГОСТ ISO 9000-2011, ГОСТ ИСО/МЭК 17025-2009 и других.

MET/CAL-IEEE USB 2 контроллера National Instruments с интерфейсным кабелем USB-IEEE-488 / 2 National Instruments USB-To-GPIB Controllers.

Fluke 5502A и Fluke 5502E Перечень моделей

Fluke 5502A и Fluke 5502E Перечень опций

Fluke 5502A и Fluke 5502E Документация

  • Home
  • Brands
  • Fluke
  • Test Equipment
  • 5502E
  • Getting Started

Manual for Fluke 5502E Test Equipment (48 pages)

Specifications:

1046/1046260-5502e.pdf file (25 Oct 2022)

Fluke 5502E: Read PDF Manual Online

Accompanying Data:

Fluke 5502E Test Equipment PDF Getting Started (Updated: Tuesday 25th of October 2022 01:47:12 AM)

Rating: 4.3 (rated by 87 users)

Compatible devices: 190-102, 714, Versiv Series, 5700A Series, DTX-PC S Series, P3000 Series, DTX-CLT CertiFiber, 154 HART.

Recommended Documentation:

Fluke 5502E: Text of Manual, Getting Started

(Ocr-Read Version Summary of Contents, UPD: 25 October 2022)

  • 1, PN 4238530 November 2012 © 2012 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. 5502E Multi-Product Calibrator Getting Started

  • 16, 5502E Getting Started 6 Remote Operation (RS-232) There are two rear-panel serial data RS-232 ports: SERIAL 1 FROM HOST, and SERIAL 2 TO UUT (see Figure 2). Each port is dedicated to serial-data communications to operate and control the Product during calibration procedures. For complete information on remote operation, see Chapter 5 of the Operators Manua…

  • 29, Multi-Product Calibrator Detailed Specifications 19 Capacitance Range Absolute Uncertainty, tcal ±5 °C ±(% of output + floor) [1] [2] [3] Resolution Allowed Frequency or Charge-Discharge Rate 90 Day 1 Year Min and Max to Meet Specification Typical Max for <0.5 % Error Typical Max for <1 % Error 220.0 to 399.9 pF 0.38 + 0.01 nF 0.5 + 0.…

  • 12, 5502E Getting Started 2 0 • 123 4 5 6 7 8 9 ENTER M k m V Hz / + F OPR STBY EARTH TRIG OUT SCOPE ME NU PREV SHIFT RESET CE SETUP REF NEW TC MEAS ¡F n p W dBm sec ¡C POWER A MULT x DIV CAL ZERO FIELD EDIT 5502E CALIBRATOR gvw001.eps Figure 1. 5502E Multi-Product Calibrator Calibrator features include: • Automatic meter error calculation, with referen…

  • 30, 5502E Getting Started 20 Temperature Calibration (Thermocouple) TC Type [1] Range °C [2] Absolute Uncertainty Source/Measure tcal ±5 °C ± °C [3] TC Type [1] Range °C [2] Absolute Uncertainty Source/Measure tcal ±5 °C ± °C [3] 90 Day 1 Year 90 Day 1 Year B 600 to 800 0.42 0.44 L -200 to -100 0.37 0.37 800 to 1000 0.3…

  • 17, Multi-Product Calibrator Unpack and Inspection 7 Unpack and Inspection The calibrator is shipped in a container to prevent damage. Examine the calibrator carefully for damage and immediately report damage to the shipper. Instructions for inspection and claims are included in the shipping container. When you unpack the calibrator, make sure that you have all the standard equipment in Ta…

  • 19, Multi-Product Calibrator Select Line Frequency 9 100V/120V 220V/240V T5.0A 250V (SB) T2.5A 250V (SB) /63Hz 47Hz 600VA MAX WARNING: TO AVOID ELECTRIC SHOCK GROUNDING CONNECTOR IN POWER CORD MUST BE CONNECTED FUSE MAINS SUPPLY CHASSIS GROUND WARNING: TO AVOID PHYSICAL INJURY, INSURE THA IS PROPERLY INSTALLED BEFORE ENERGIZING INSTRU CAUTION …

  • 40, 5502E Getting Started 30 Table 7. Verification Tests for AC Voltage (Normal) Range Output Frequency Lower Limit Upper Limit 32.999 mV 3.000 mV 45 Hz 2.977 mV 3.022 mV 32.999 mV 3.000 mV 10 kHz 2.977 mV 3.022 mV 32.999 mV 30.000 mV 9.5 Hz 28.350 mV 31.650 mV, 32.999 mV 30.000 mV 10 Hz 29.944 mV 30.056 mV 32.999 mV 30.000 mV 45 Hz 29.9…

  • 15, Multi-Product Calibrator Contact Fluke Calibration 5 Contact Fluke Calibration To contact Fluke Calibration, call one of the following telephone numbers: • Technical Support USA: 1-877-355-3225 • Calibration/Repair USA: 1-877-355-3225 • Canada: 1-800-36-FLUKE (1-800-363-5853) • Europe: +31-40-2675-200 • Japan: +81-3-6714-3114 • Singapore: +65-67…

  • 44, 5502E Getting Started 34 Table 8. Verification Tests for AC Current (cont.) Range Output Frequency Lower Limit Upper Limit 2.99999 A 2.99000 A 10 kHz 2.92520 A 3.05480 A 20.5000 A 3.3000 A 500 Hz 3.2954 A 3.3046 A 20.5000 A 3.3000 A 1 kHz 3.2954 A 3.3046 A 20.5000 A 3.3000 A 5 kHz 3.2155 A 3.3845 A 20.5000 A 11.0000 A 45 Hz 10.9840A 11.0160 A 20.5000 A 11.000…

  • 18, 5502E Getting Started 8 Connect to Line Power Warning To prevent possible electrical shock, fire, or personal injury: • Do not use a two-conductor mains power cord unless you install a protective ground wire to the Product ground terminal before you operate the Product. • Do not use an extension cord or adapter plug. Make sure that the Product is …

DOC-a7bbcc86:

Fluke 5502E: Recommended Instructions

AY-AP7FHR, U-PHORIA UM2, RT3300MC, ProLiant DL360 G6, 52SX4D, ABM-600

  • User’s Guide Publication Number 54622-97014August 2000For Safety Information, Warranties, and Regulatory information,see the pages behind the Index.© Copyright Agilent Technologies 2000All Rights ReservedAgilent 54621A/22A/24A Oscilloscopes and Agilent 54621D/22D Mixed-Signal Oscilloscopes …

    54622A 234

  • 1. Port 1, Tx Bantam (DS1) 2. Port 1, Tx BNC (E1, E3, E4, DS3, STM-1e, STS-3) 3. Port 1, Rx Bantam (DS1) 4. Port 1, Rx BNC (E1, E3, E4, DS3, STM-1e, STS-3) 5. Port 2, Tx Bantam (DS1) 6. Port 2, Tx BNC (E1, E3, E4, DS3, STM-1e, STS-3) 7. Port 2, Rx Bantam (DS1) 8. Port 2, Rx BNC (E1, E3, E4, DS3, STM-1e, STS-3) 9. Port 1, Tx/Rx RJ48 (E1 balanced) 10. Port 2, Tx/Rx RJ48 (E1 balanced …

    MT1000A Network Master Pro 4

  • (217) 352-9330 | [email protected] | artisantg.com-~ ARTISAN® ~I TECHNOLOGY GROUP Your definitive source for quality pre-owned equipment. Artisan Technology Group Full-service, independent repair center with experienced engineers and technicians on staff. We buy your excess, underutilized, and idle equipment along with credit for buybacks and trade-ins. Custom engineering so your equipme …

    GTS1063 120

  • 1Table of ContentsTitle PageOverviewUnpacking InspectionSafety InformationRules For Safe OperationInternational Electrical SymbolsThe Meter StructureLCD IndicatorsRotary SwitchFunctional ButtonsMeasurement Operation A. AC/DC Voltage MeasurementB. AC/DC Current MeasurementC. Resistance MeasurementD. Diod …

    121416 27

  • UT522 USERS MANUAL1ContentChapter Page25691011181. Safety Instructions2. Characteristics3. General Specifications4. Product outlook & accessories5. Preparation before measurement6. Measurement Operation7. Maintenance & Repair …

    UT522 21

  • 1 Battery Electrical System Analyser (12-1012) For testing all 12V automotive starting batteries rated in CCA, DIN, IEC, JIS# and EN. Also for testing vehicle Electrical System. Quick Start Guide Caution: Never lay tools on the battery top. You may short the terminals together causing harm to yourself, the tools or the battery. Always follow B …

    12-1012 8

  • — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ▲ INSTRUCTION MANUAL 3601 E. 34th St. Tucson, AZ 85713 USA Tel. +1 520-882-6598 Fax +1 520-882-6599 email: [email protected] Web: http://www.metallographic.com Please read this instruction manual carefully and follow all installation, operating and saf …

    Rockwell OMEGA-RT-60/150 33

  • F-2000 HAY MOISTURE METER OPERATION MANUAL DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK ‘s-HERTOGENBOSCH THE NETHERLANDS [email protected] www.MoistureMetersDelmhorst.com +31 (0)73 6395080 …

    F-2000 12

  • DIGITAL BATTERY TESTER Operation and Safety Notes DIGITALER BATTERIETESTER Bedienungs- und Sicherheitshinweise DIGITALNI APARAT ZA TESTIRANJE BATERIJA Upute za posluživanje i za Vašu sigurnost ΨΗΦΙΑΚΗ ΕΛΕΓΚΤΙΚΗ ΣΥΣΚΕΥΗ ΜΠΑΤΑΡΙΩΝ Υποδείξεις χειρισμού και ασφαλείας TESTER DIGITAL PENTRU BATERII Instrucţiuni de utilizare � …

    Z30508 24

Additional Information:

Popular Right Now:
Operating Impressions, Questions and Answers:

Калибратор – микропроцессорный прибор генераторного типа, обладающий возможно — стью автоматической калибровки по внутриприборным мерам, самодиагностикой, стандартными интерфейсами IEEE-488, RS-232. Основной частью калибратора являются встроенные прецизионные источники сигналов различной формы, опорными из которых являются источник напряжения постоянного тока, кварцевый генератор частоты, термопреобразователь напряжения переменного тока в постоянное напряжение, набор высокоточных и высокостабильных резисторов.

Назначение многоцелевого калибратора Fluke 5502E:

  • воспроизведения напряжения постоянного тока;
  • воспроизведения силы постоянного тока;
  • воспроизведения электрического сопротивления постоянному току;
  • воспроизведения напряжения переменного тока;
  • воспроизведения силы переменного тока;
  • воспроизведения электрической емкости;
  • формирования сигналов синусоидальной, прямоугольной, треугольной формы.

Понравилась статья? Поделить с друзьями:
  • Полисорб инструкция по применению взрослым для очищения после таблеток
  • Руководство для биоса
  • Как создать гугл аккаунт для андроид через телефон пошаговая инструкция
  • Sony wi xb400 инструкция на русском
  • Руководство педагогическим коллективом в условиях реализации фгос ответ на вопрос билета