Руководство пользователя сервера HPE ProLiant DL360 Gen10
Загрузить pdf
-
Contents
-
Table of Contents
-
Troubleshooting
-
Bookmarks
Quick Links
HP ProLiant DL120 G7 Server
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. This document is intended for experienced
IT professionals or end-users with no or prior hardware setup experience. HP assumes you are qualified in the servicing of computer equipment and
trained in recognizing hazards in products with hazardous energy levels.
Part Number: 638025-003
September 2012
Edition: 3
Troubleshooting
Summary of Contents for HP ProLiant DL120 G7
Инструкции по эксплуатации
Укажите здесь торговую марку и тип
В настоящее время вы находитесь на странице с руководствами . Выберите один из продуктов, чтобы сразу перейти к руководству по этому продукту. Не можете найти ? Тогда попробуйте вбить в поле поиска и модель, чтобы найти нужное руководство . На ManualsPDF.ru в настоящее время имеется 192 руководств . Самые популярные :
- HP ProLiant DL380p G8
- HP HPE ProLiant DL360 Gen9
- HP ProLiant DL360 Gen10
Последнее добавленное руководство было добавлено 2022-04-30, и это HP ProLiant DL360 Gen10+.
HP ProLiant DL120 G7 Server
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. This document is intended for experienced
IT professionals or end-users with no or prior hardware setup experience. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 638025-003a
April 2014
Edition: 3
© Copyright 2011, 2014 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Microsoft® and Windows® are U.S. registered trademarks of Microsoft Corporation.
Bluetooth® is a trademark owned by its proprietor and used by Hewlett-Packard Company under license.
Contents
Component identification ………………………………………………………………………………………………… 7
Front panel components ……………………………………………………………………………………………………………….. 7
Front panel LEDs ………………………………………………………………………………………………………………………… 8
Rear panel components ……………………………………………………………………………………………………………….. 8
Rear panel LEDs …………………………………………………………………………………………………………………………. 9
PCIe expansion slot definitions …………………………………………………………………………………………………….. 10
System board components ………………………………………………………………………………………………………….. 10
System board LEDs …………………………………………………………………………………………………………… 11
System maintenance switch ………………………………………………………………………………………………… 11
NMI functionality …………………………………………………………………………………………………………….. 12
DIMM slot locations ………………………………………………………………………………………………………….. 12
SAS and SATA device numbering …………………………………………………………………………………………………. 13
SAS and SATA drive LEDs …………………………………………………………………………………………………………… 13
BBWC module LEDs ………………………………………………………………………………………………………………….. 14
Fan locations …………………………………………………………………………………………………………………………… 15
T-10/T15 Torx screwdriver ………………………………………………………………………………………………………….. 16
Operations………………………………………………………………………………………………………………… 17
Power up the server …………………………………………………………………………………………………………………… 17
Power down the server ………………………………………………………………………………………………………………. 17
Remove the server from the rack …………………………………………………………………………………………………… 17
Remove the access panel ……………………………………………………………………………………………………………. 18
Install the access panel ………………………………………………………………………………………………………………. 18
Remove the PCIe riser cage …………………………………………………………………………………………………………. 18
Install the PCIe riser cage ……………………………………………………………………………………………………………. 19
Remove the air baffle …………………………………………………………………………………………………………………. 19
Install the air baffle ……………………………………………………………………………………………………………………. 20
Setup ……………………………………………………………………………………………………………………….. 22
Optional installation services ……………………………………………………………………………………………………….. 22
Rack planning resources …………………………………………………………………………………………………………….. 22
Optimum environment………………………………………………………………………………………………………………… 22
Space and airflow requirements ………………………………………………………………………………………….. 23
Temperature requirements ………………………………………………………………………………………………….. 23
Power requirements ………………………………………………………………………………………………………….. 24
Electrical grounding requirements ………………………………………………………………………………………… 24
Rack warnings …………………………………………………………………………………………………………………………. 24
Identifying the contents of the server shipping carton ………………………………………………………………………….. 25
Installing hardware options …………………………………………………………………………………………………………. 25
Installing the server into the rack …………………………………………………………………………………………………… 25
Powering up and configuring the server ………………………………………………………………………………………….. 26
Installing the operating system ……………………………………………………………………………………………………… 26
Registering the server…………………………………………………………………………………………………………………. 27
Hardware options installation …………………………………………………………………………………………. 28
Introduction …………………………………………………………………………………………………………………………….. 28
Memory options ……………………………………………………………………………………………………………………….. 28
Contents 3
Memory subsystem architecture …………………………………………………………………………………………… 28
Single-rank and dual-rank DIMMs ………………………………………………………………………………………… 28
DIMM identification ………………………………………………………………………………………………………….. 29
UDIMM maximum memory configurations ………………………………………………………………………………. 29
Memory configuration ………………………………………………………………………………………………………. 30
General DIMM slot population guidelines ………………………………………………………………………………. 30
Installing a DIMM …………………………………………………………………………………………………………….. 30
Drive options …………………………………………………………………………………………………………………………… 31
Drive guidelines ………………………………………………………………………………………………………………. 31
Removing a drive blank …………………………………………………………………………………………………….. 31
Removing a drive …………………………………………………………………………………………………………….. 32
Installing a hot-plug drive …………………………………………………………………………………………………… 33
Optical drive option ………………………………………………………………………………………………………………….. 33
Dedicated iLO management port module option ……………………………………………………………………………….. 35
Expansion board option ……………………………………………………………………………………………………………… 36
Storage controller option …………………………………………………………………………………………………………….. 37
BBWC module and battery pack option …………………………………………………………………………………………. 38
Redundant hot-plug power supply option (with cage) …………………………………………………………………………. 40
HP Trusted Platform Module option ……………………………………………………………………………………………….. 44
Installing the Trusted Platform Module board …………………………………………………………………………… 45
Retaining the recovery key/password ……………………………………………………………………………………. 46
Enabling the Trusted Platform Module ……………………………………………………………………………………. 46
Cabling ……………………………………………………………………………………………………………………. 48
Cabling overview ……………………………………………………………………………………………………………………… 48
Server cabling …………………………………………………………………………………………………………………………. 48
Nonredundant power supply cabling …………………………………………………………………………………………….. 48
Redundant power supply cabling ………………………………………………………………………………………………….. 49
Internal USB cabling ………………………………………………………………………………………………………………….. 49
BBWC battery cabling ……………………………………………………………………………………………………………….. 50
Optical drive cabling …………………………………………………………………………………………………………………. 51
SATA cabling ………………………………………………………………………………………………………………………….. 51
SAS cabling ……………………………………………………………………………………………………………………………. 52
Configuration and utilities ……………………………………………………………………………………………… 54
Configuration tools ……………………………………………………………………………………………………………………. 54
SmartStart software ………………………………………………………………………………………………………….. 54
HP ROM-Based Setup Utility ……………………………………………………………………………………………….. 54
Array Configuration Utility …………………………………………………………………………………………………. 56
Option ROM Configuration for Arrays…………………………………………………………………………………… 57
Re-entering the server serial number and product ID ………………………………………………………………….. 57
Management tools…………………………………………………………………………………………………………………….. 58
Automatic Server Recovery …………………………………………………………………………………………………. 58
ROMPaq utility ………………………………………………………………………………………………………………… 58
Integrated Lights-Out 3 technology ……………………………………………………………………………………….. 58
Erase Utility ……………………………………………………………………………………………………………………. 59
USB support …………………………………………………………………………………………………………………… 59
Diagnostic tools ……………………………………………………………………………………………………………………….. 59
HP Insight Diagnostics ………………………………………………………………………………………………………. 59
HP Insight Diagnostics survey functionality ……………………………………………………………………………… 60
Integrated Management Log ……………………………………………………………………………………………….. 60
Remote support and analysis tools ………………………………………………………………………………………………… 60
HP Insight Remote Support software ……………………………………………………………………………………… 60
Keeping the system current ………………………………………………………………………………………………………….. 61
Contents 4
Drivers ………………………………………………………………………………………………………………………….. 61
Version control ………………………………………………………………………………………………………………… 61
ProLiant Support Packs ………………………………………………………………………………………………………. 62
Operating System Version Support ……………………………………………………………………………………….. 62
Firmware ……………………………………………………………………………………………………………………….. 62
HP Smart Update Manager ………………………………………………………………………………………………… 62
Change control and proactive notification ……………………………………………………………………………… 63
Care Pack ……………………………………………………………………………………………………………………… 63
Troubleshooting ………………………………………………………………………………………………………….. 64
Pre-diagnostic steps …………………………………………………………………………………………………………………… 64
Important safety information ……………………………………………………………………………………………….. 64
Symptom information ………………………………………………………………………………………………………… 66
Prepare the server for diagnosis …………………………………………………………………………………………… 66
Loose connections …………………………………………………………………………………………………………………….. 68
Service notifications …………………………………………………………………………………………………………………… 68
Server health LEDs …………………………………………………………………………………………………………………….. 68
Troubleshooting flowcharts ………………………………………………………………………………………………………….. 69
Start diagnosis flowchart ……………………………………………………………………………………………………. 69
General diagnosis flowchart ……………………………………………………………………………………………….. 70
Server power-on problems flowchart …………………………………………………………………………………….. 72
POST problems flowchart …………………………………………………………………………………………………… 75
OS boot problems flowchart ……………………………………………………………………………………………….. 77
Server fault indications flowchart …………………………………………………………………………………………. 78
POST error messages and beep codes …………………………………………………………………………………………… 80
Battery ……………………………………………………………………………………………………………………… 82
Regulatory compliance notices ……………………………………………………………………………………….. 83
Regulatory compliance identification numbers ………………………………………………………………………………….. 83
Federal Communications Commission notice ……………………………………………………………………………………. 83
FCC rating label ……………………………………………………………………………………………………………… 83
FCC Notice, Class A Equipment ………………………………………………………………………………………….. 83
Declaration of conformity for products marked with the FCC logo, United States only …………………………………. 84
Modifications …………………………………………………………………………………………………………………………… 84
Cables …………………………………………………………………………………………………………………………………… 84
Canadian notice (Avis Canadien) …………………………………………………………………………………………………. 84
European Union regulatory notice …………………………………………………………………………………………………. 84
Disposal of waste equipment by users in private households in the European Union …………………………………… 85
Japanese class A notice ……………………………………………………………………………………………………………… 85
BSMI notice …………………………………………………………………………………………………………………………….. 86
Korean class A notice ………………………………………………………………………………………………………………… 86
Chinese notice …………………………………………………………………………………………………………………………. 86
Laser compliance ……………………………………………………………………………………………………………………… 86
Battery replacement notice ………………………………………………………………………………………………………….. 87
Taiwan battery recycling notice ……………………………………………………………………………………………………. 87
Power cord statement for Japan ……………………………………………………………………………………………………. 87
Electrostatic discharge ………………………………………………………………………………………………….. 88
Preventing electrostatic discharge …………………………………………………………………………………………………. 88
Grounding methods to prevent electrostatic discharge ………………………………………………………………………… 88
Specifications …………………………………………………………………………………………………………….. 89
Environmental specifications ………………………………………………………………………………………………………… 89
Mechanical specifications …………………………………………………………………………………………………………… 89
Contents 5
Power supply specifications …………………………………………………………………………………………………………. 89
Support and other resources ………………………………………………………………………………………….. 91
Before you contact HP ……………………………………………………………………………………………………………….. 91
HP contact information ……………………………………………………………………………………………………………….. 91
Customer Self Repair …………………………………………………………………………………………………………………. 91
Acronyms and abbreviations ………………………………………………………………………………………….. 99
Documentation feedback …………………………………………………………………………………………….. 102
Index ……………………………………………………………………………………………………………………… 103
Contents 6
Component identification
Front panel components
•
SFF model
3
4
1
2
Item Description
Optical drive
Serial label pull tab
USB connectors (2)
Drive bays
•
LFF model
3
4
1
2
Item Description
Optical drive
Serial label pull tab
USB connectors (2)
Drive bays
Component identification 7
Front panel LEDs
Item Description
1
Internal health LED
2
3
4
5
6
NIC 1 link/activity LED
NIC 2 link/activity LED
Drive activity LED
Power On/Standby button and system power LED
UID button/LED
Status
Green = Normal
Amber = System degraded
Red = System critical
Off = Normal (when in standby mode)
Green = Network link
Flashing green = Network link and activity
Off = No network link
If the power is off, view the LEDs on the RJ-45 connector.
Green = Network link
Flashing green = Network link and activity
Off = No link to network
If the power is off, view the LEDs on the RJ-45 connector.
Green = Drive active
Off = No drive activity
Green = Normal (system on)
Amber = System in standby, but power is still applied
Off = Power cord not attached or the power supply failed
Blue = Activated
Flashing blue = System being managed remotely
Off = Deactivated
Rear panel components
3
4
Item Description
1
Power cord connector
2
Video connector
Serial connector
10/100/1000 NIC 2 connector
Component identification 8
8
9
6
7
10
Item Description
5
10/100/1000 NIC 1 connector/ shared iLO management port
HP dedicated iLO management port (optional)
USB connectors (4)
T10/T15 tool
Slot 1 PCIe2 x16 (16, 8, 4, 1)
Slot 2 PCIe2 x8 (4, 1)
Rear panel LEDs
2
3
4
5
Item
1
Description Status
UID button/LED
NIC2 link LED
Blue = Identification
Flashing blue = System is being managed remotely
Off = Off
Green = 10M/100M/1G link speed
Off = No connection
NIC2 activity LED Green = Linked to the network
Flashing green = Linked and activity on the network
Off = No network activity
NIC1 link LED Green = 10M/100M/1G link speed
Off = No connection
NIC1 activity LED Green = Linked to the network
Flashing green = Linked and activity on the network
Off = No network activity
Component identification 9
PCIe expansion slot definitions
Slot
1
2
Type
PCIe2
PCIe2
Length
Full
Half
Connector x16 x8
System board components
Interconnect x16 x4
Item
1
15
16
17
18
9
10
11
12
13
14
19
20
7
8
5
6
2
3
4
Description
DIMM slots 1-4
Processor socket
System power connector (24 pin)
Fan connector 7 (Reserved)
Fan connector 8 (Reserved)
Fan connector 3
Fan connector 4
RPS connector
Fan connector 5
System battery
I 2 C cable connector
SATA connectors
SD card slot
Mini-SAS connector
Front panel connector
Fan connector 6
Front USB connectors
Internal USB connector
PCIe riser board connectors
Reserved
Component identification 10
Item
21
22
23
24
Description
TPM connector
Power supply connector (4 pin)
System maintenance switch
HP dedicated iLO management connector
System board LEDs
Item LED description
1
2
Power supply 1 failure
Power supply 2
(redundant) failure
Status
Red = Power supply 1 failed
Off = Normal
Red = Power supply 2 failed
Off = Normal
System maintenance switch
Position Default Function
1
Off
2
3
4
5
6
7
Off
Off
Off
Off
Off
Off
Off = iLO 3 security is enabled
On = iLO 3 security is disabled
Off = System configuration can be changed
On = System configuration is locked
Reserved
Reserved
Off = Password is enabled
On = Password is disabled
Off = No function
On = Clear NVRAM
Reserved
Component identification 11
Position
8
Default
Off
Function
Reserved
9
10
Off
Off
Reserved
Reserved
When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all system configuration settings from both CMOS and NVRAM.
CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to properly configure the server or data loss could occur.
NMI functionality
An NMI crash dump enables administrators to create crash dump files when a system is hung and not responding to traditional debug mechanisms.
Crash dump log analysis is an essential part of diagnosing reliability issues, such as hangs in operating systems, device drivers, and applications. When crashes freeze a system, administrators must cycle the system power. Resetting the system erases any information that support issue analysis, but the NMI feature preserves that information by performing a memory dump before a hard reset.
The administrator must use the iLO Virtual NMI feature to force the OS to invoke the NMI handler and generate a crash dump log.
For additional information, see the HP website
( http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00797875/c00797875.pdf
).
DIMM slot locations
DIMM slots are numbered sequentially for the processor.
Populate the DIMM slots in the following sequence:
•
1 DIMM: 2A
Component identification 12
•
2 DIMMs: 2A+4B
•
3 DIMMs: 2A+4B+1C
•
4 DIMMs: All DIMMs
SAS and SATA device numbering
•
LFF device bay numbering
•
SFF device bay numbering
SAS and SATA drive LEDs
Item Description
1
Fault/UID LED (amber/blue)
2
Online LED (green)
Component identification 13
BBWC module LEDs
Item ID Color
1
2
3
Green
Green
Amber
Description
System Power LED. This LED illuminates steadily when the system is powered up and 12-V system power is available.
This power supply is used to maintain the battery charge and provide supplementary power to the cache microcontroller.
Auxiliary Power LED. This LED illuminates steadily when 3.3
V auxiliary voltage is detected. The auxiliary voltage is used to preserve BBWC data and is available any time that the system power cords are connected to a power supply.
Battery Health LED. To interpret the illumination patterns of this LED, see the following table.
BBWC Status LED. To interpret the illumination patterns of this LED, see the following table.
4
Green
LED3 pattern
—
—
LED4 pattern
One flash every two seconds
Double flash, then pause
Interpretation
The system is powered down, and the cache contains data that has not yet been written to the drives. Restore system power as soon as possible to prevent data loss.
If 3.3 V auxiliary power is available, as indicated by LED 2, then data preservation time is extended. If no auxiliary power is available, only battery power preserves the data. A fully-charged battery can normally preserve data for at least two days.
The battery lifetime also depends on the cache module size. For more information, see the controller QuickSpecs on the HP website
( http://www.hp.com
).
The cache microcontroller is waiting for the host controller to communicate.
Component identification 14
LED3 pattern
—
—
—
One flash per second
Steady glow
One flash per second
Fan locations
LED4 pattern
One flash per second
Steady glow
Off
One flash per second
—
—
Interpretation
The battery pack is below the minimum charge level and is being charged. Features that require a battery (such as write cache, capacity expansion, stripe size migration, and RAID migration) are temporarily unavailable until charging is complete. The recharge process takes between 15 minutes and 2 hours, depending on the initial capacity of the battery.
The battery pack is fully charged, and posted write data is stored in the cache.
The battery pack is fully charged, and write data is not posted in the cache.
An alternating green and amber blink pattern indicates that the cache microcontroller is executing from within its boot loader and receiving new flash code from the host controller.
There is a short circuit across the battery terminals or within the battery pack. BBWC features are disabled until the battery pack is replaced.
The life expectancy of a battery pack is typically more than three years.
An open circuit is across the battery terminals or within the battery pack. BBWC features are disabled until the battery pack is replaced.
The life expectancy of a battery pack is typically more than three years.
Component identification 15
T-10/T15 Torx screwdriver
The server includes a T-10/T-15 Torx screwdriver located on the rear panel of the server. Use the screwdriver to loosen screws during hardware configuration procedures.
Component identification 16
Operations
Power up the server
1.
2.
3.
Connect each power cord to the server.
Connect each power cord to the power source.
Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes from amber to green.
Power down the server
Before powering down the server for any upgrade or maintenance procedures, perform a backup of critical server data and programs.
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power On/Standby button does not completely shut off system power. Portions of the power supply and some internal circuitry remain active until AC/DC power is removed.
IMPORTANT: When the server is in standby mode, auxiliary power is still being provided to the system.
To power down the server, use one of the following methods:
•
Press and release the Power On/Standby button.
This method initiates a controlled shutdown of applications and the OS before the server enters standby mode.
•
Press and hold the Power On/Standby button for more than 4 seconds to force the server to enter standby mode.
This method forces the server to enter standby mode without properly exiting applications and the OS.
If an application stops responding, you can use this method to force a shutdown.
•
Use a virtual power button selection through iLO 3.
This method initiates a controlled remote shutdown of applications and the OS before the server enters standby mode.
Before proceeding, verify the server is in standby mode by observing that the system power LED is amber.
Remove the server from the rack
WARNING: The server is not attached to the rack mounting rails. To avoid potential damage to the server and personal injury, always support the server with both hands when removing it from the rack.
Operations 17
To remove the server from an HP, Compaq branded, TELCO, or third-party rack:
1.
Power down the server (on page 17 ).
2.
3.
4.
5.
Disconnect all peripheral cables and power cords from the server rear panel.
Loosen the thumbscrews that secure the server faceplate to the front of the rack.
Remove the server from the rack. For more information, see the documentation that ships with the rack mounting option.
Place the server on a sturdy, level surface.
Remove the access panel
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize the amount of time the access panel is open.
1.
2.
3.
Power down the server (on page 17 ).
Remove the server from the rack (on page 17 ).
Press the hood latch button, slide the access panel to the rear of the chassis, and then remove the access panel.
If the access panel is locked, use a T-10 Torx screwdriver to unlock the hood lock screw.
Install the access panel
1.
2.
3.
Place the access panel on top of the server. Allow the panel to extend past the rear of the server approximately 1.25 cm (0.5 inch).
Slide the panel to the front of the chassis until it is well engaged with the hard drive cage.
Use the T-10 Torx screwdriver attached to the rear of the server to tighten the hood lock screw on the hood.
Remove the PCIe riser cage
CAUTION: To prevent damage to the server or expansion boards, power down the server and remove all AC power cords before removing or installing the PCIe riser board assembly.
1.
2.
3.
4.
5.
Power down the server (on page 17 ).
Remove the server from the rack (on page 17 ).
Remove the access panel (on page 18 ).
Disconnect all internal cables connected to existing expansion boards.
Remove the PCIe riser cage: a. b.
Remove the T-10 screw.
Remove the T-15 screws.
Operations 18
c.
Remove the riser cage.
Install the PCIe riser cage
CAUTION: To prevent damage to the server or expansion boards, power down the server and remove all AC power cords before removing or installing the PCIe riser board assembly.
1.
Install the PCIe riser cage.
2.
3.
4.
Connect any internal cables for expansion boards.
Install the access panel (on page 18 ).
Install the server into the rack (» Installing the server into the rack » on page 25 ).
Remove the air baffle
Operations 19
1.
2.
3.
CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize the amount of time the access panel is open.
Power down the server (on page 17 ).
Remove the access panel (on page 18 ).
Remove the air baffle.
Install the air baffle
CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize the amount of time the access panel is open.
1.
Install the air baffle.
Operations 20
2.
3.
Install the access panel (on page 18 ).
Power up the server (» Powering up and configuring the server » on page 26
, on page 17 ).
Operations 21
Setup
Optional installation services
Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and running with support packages tailored specifically for HP ProLiant systems. HP Care Packs let you integrate both hardware and software support into a single package. A number of service level options are available to meet your needs.
HP Care Pack Services offer upgraded service levels to expand your standard product warranty with easy-to-buy, easy-to-use support packages that help you make the most of your server investments. Some of the Care Pack services are:
•
Hardware support o
6-Hour Call-to-Repair o o
4-Hour 24×7 Same Day
4-Hour Same Business Day
•
Software support o
Microsoft® operating systems o o
Linux operating systems
HP ProLiant Essentials (HP SIM and RDP)
•
Integrated hardware and software support o
Critical Service o o o
Proactive 24
Support Plus
Support Plus 24
•
Startup and implementation services for both hardware and software
For more information on HP Care Pack Services, see the HP website
( http://www.hp.com/services/carepack ).
Rack planning resources
The rack resource kit ships with all HP branded or Compaq branded 9000, 10000, and H9 series racks. For more information on the content of each resource, see the rack resource kit documentation.
Optimum environment
When installing the server in a rack, select a location that meets the environmental standards described in this section.
Setup 22
Space and airflow requirements
Rack server
To allow for servicing and adequate airflow, observe the following space and airflow requirements when deciding where to install a rack:
•
Leave a minimum clearance of 63.5 cm (25 in) in front of the rack.
•
Leave a minimum clearance of 76.2 cm (30 in) behind the rack.
•
Leave a minimum clearance of 121.9 cm (48 in) from the back of the rack to the back of another rack or row of racks.
HP servers draw in cool air through the front door and expel warm air through the rear door. Therefore, the front and rear rack doors must be adequately ventilated to allow ambient room air to enter the cabinet, and the rear door must be adequately ventilated to allow the warm air to escape from the cabinet.
CAUTION: To prevent improper cooling and damage to the equipment, do not block the ventilation openings.
When vertical space in the rack is not filled by a server or rack component, the gaps between the components cause changes in airflow through the rack and across the servers. Cover all gaps with blanking panels to maintain proper airflow.
CAUTION: Always use blanking panels to fill empty vertical spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.
The 9000 and 10000 Series Racks provide proper server cooling from flow-through perforations in the front and rear doors that provide 64 percent open area for ventilation.
CAUTION: When using a Compaq branded 7000 series rack, install the high airflow rack door insert (PN 327281-B21 for 42U rack, PN 157847-B21 for 22U rack) to provide proper front-to-back airflow and cooling.
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
•
Front and rear doors—If the 42U rack includes closing front and rear doors, you must allow
5,350 sq cm (830 sq in) of holes evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
•
Side—The clearance between the installed rack component and the side panels of the rack must be a minimum of 7 cm (2.75 in).
Temperature requirements
To ensure continued safe and reliable equipment operation, install or position the system in a well-ventilated, climate-controlled environment.
The maximum recommended ambient operating temperature (TMRA) for most server products is 35°C
(95°F). The temperature in the room where the rack is located must not exceed 35°C (95°F).
Setup 23
CAUTION: To reduce the risk of damage to the equipment when installing third-party options:
•
Do not permit optional equipment to impede airflow around the server or to increase the internal rack temperature beyond the maximum allowable limits.
• Do not exceed the manufacturer’s TMRA.
Power requirements
Installation of this equipment must comply with local and regional electrical regulations governing the installation of information technology equipment by licensed electricians. This equipment is designed to operate in installations covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992
(code for Protection of Electronic Computer/Data Processing Equipment). For electrical power ratings on options, refer to the product rating label or the user documentation supplied with that option.
WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supply branch circuit that provides power to the rack. Consult the electrical authority having jurisdiction over wiring and installation requirements of your facility.
CAUTION: Protect the server from power fluctuations and temporary interruptions with a regulating uninterruptible power supply. This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure.
When installing more than one server, you may need to use additional power distribution devices to safely provide power to all devices. Observe the following guidelines:
•
Balance the server power load between available AC supply branch circuits.
•
Do not allow the overall system AC current load to exceed 80% of the branch circuit AC current rating.
•
Do not use common power outlet strips for this equipment.
•
Provide a separate electrical circuit for the server.
Electrical grounding requirements
The server must be grounded properly for proper operation and safety. In the United States, you must install the equipment in accordance with NFPA 70, 1999 Edition (National Electric Code), Article 250, as well as any local and regional building codes. In Canada, you must install the equipment in accordance with
Canadian Standards Association, CSA C22.1, Canadian Electrical Code. In all other countries, you must install the equipment in accordance with any regional or national electrical wiring codes, such as the
International Electrotechnical Commission (IEC) Code 364, parts 1 through 7. Furthermore, you must be sure that all power distribution devices used in the installation, such as branch wiring and receptacles, are listed or certified grounding-type devices.
Because of the high ground-leakage currents associated with multiple servers connected to the same power source, HP recommends the use of a PDU that is either permanently wired to the building’s branch circuit or includes a nondetachable cord that is wired to an industrial-style plug. NEMA locking-style plugs or those complying with IEC 60309 are considered suitable for this purpose. Using common power outlet strips for the server is not recommended.
Rack warnings
Setup 24
WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that:
•
The leveling jacks are extended to the floor.
•
The full weight of the rack rests on the leveling jacks.
• The stabilizing feet are attached to the rack if it is a single-rack installation.
•
The racks are coupled together in multiple-rack installations.
•
Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason.
WARNING: To reduce the risk of personal injury or equipment damage when unloading a rack:
•
At least two people are needed to safely unload the rack from the pallet. An empty 42U rack can weigh as much as 115 kg (253 lb), can stand more than 2.1 m (7 ft) tall, and might become unstable when being moved on its casters.
•
Never stand in front of the rack when it is rolling down the ramp from the pallet. Always handle the rack from both sides.
Identifying the contents of the server shipping carton
Unpack the server shipping carton and locate the materials and documentation necessary for installing the server. All the rack mounting hardware necessary for installing the server into the rack is included with the rack or the server.
The contents of the server shipping carton include:
•
Server
•
Power cord
•
Hardware documentation, Documentation CD, and software products
•
Rack-mounting hardware
In addition to the supplied items, you might need:
•
Operating system or application software
•
Hardware options
Installing hardware options
Install any hardware options before initializing the server. For options installation information, refer to the
option documentation. For server-specific information, refer to «Hardware options installation (on page 28 ).»
Installing the server into the rack
CAUTION: Always plan the rack installation so that the heaviest item is on the bottom of the rack.
Install the heaviest item first, and continue to populate the rack from the bottom to the top.
1.
2.
Install the server into the rack. For more information, see the installation instructions that ship with the 1U
Quick Deploy Rail System.
Connect peripheral devices to the server. For more information, see «Rear panel components (on page
8 ).»
Setup 25
3.
4.
5.
WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into RJ-45 connectors.
Connect the power cord to the rear of the server.
Install power cord anchors.
Connect the power cord to the AC power source.
WARNING: To reduce the risk of electric shock or damage to the equipment:
• Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
•
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
•
Unplug the power cord from the power supply to disconnect power to the equipment.
•
Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server.
Powering up and configuring the server
To power up the server, press the Power On/Standby button.
While the server boots, RBSU and the ORCA utility are automatically configured to prepare the server for operating system installation.
To configure these utilities manually:
•
Press the F8 key when prompted during the array controller initialization to configure the array controller using ORCA.
•
Press the F9 key when prompted during the boot process to change the server settings using RBSU. The system is set up by default for the English language.
For more information on the automatic configuration, refer to the HP ROM-Based Setup Utility User Guide located on the Documentation CD.
Installing the operating system
To operate properly, the server must have a supported operating system installed. For the latest information on supported operating systems, see the HP website ( http://www.hp.com/go/supportos ).
Methods to install an operating system on the server include:
•
SmartStart assisted installation—Insert the SmartStart CD into the DVD-ROM drive and reboot the server.
•
Manual installation—Insert the operating system CD into the DVD-ROM drive and reboot the server. You might have to obtain additional drivers from the HP website ( http://www.hp.com/support ).
For more information, see the SmartStart installation poster in the HP ProLiant Essentials Foundation Pack included with the server.
Setup 26
Registering the server
To register the server, see the HP Registration website ( http://register.hp.com
).
Setup 27
Hardware options installation
Introduction
If more than one option is being installed, read the installation instructions for all the hardware options and identify similar steps to streamline the installation process.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server before beginning any installation procedure. Improper grounding can cause electrostatic discharge.
Memory options
The server memory subsystem supports only UDIMMs.
The server supports dual-rank, PC3-10600E (DDR3) DIMMs operating at a speed of 1333 MHz.
Depending on the processor model and the number of DIMMs installed, the memory clock speed might be reduced to 1066 or 800 MHz. For more information, see «General DIMM slot population guidelines (on
page 30 ).»
Memory subsystem architecture
The memory subsystem in this server is divided into channels. The processor supports two channels, and each channel supports two DIMM slots, as shown in the following table.
Channel Slot Slot number
A
B
C
A
D
B
1
2
3
4
This server supports only UDIMMs.
DIMM slots in this server are identified by number and by letter. Letters identify the slots to populate for specific memory modes. Slot numbers are reported by ROM messages during boot and for error reporting.
Single-rank and dual-rank DIMMs
DIMM configuration requirements are based on these classifications:
•
Single-rank DIMM—One set of memory chips that is accessed while writing to or reading from the memory.
•
Dual-rank DIMM—Two single-rank DIMMs on the same module, with only one rank accessible at a time.
Hardware options installation 28
The server memory control subsystem selects the proper rank within the DIMM when writing to or reading from the DIMM.
Dual-rank DIMMs provide the greatest capacity with the existing memory technology. For example, if current
DRAM technology supports 2-GB single-rank DIMMs, a dual-rank DIMM would be 4 GB.
DIMM identification
To determine DIMM characteristics, use the label attached to the DIMM and the following illustration and table.
Item Description
1
2
3
4
5
Size
Rank
Data width
Voltage rating
Memory speed
Definition
—
1R = Single-rank
2R = Dual-rank
4R = Quad-rank x4 = 4-bit x8 = 8-bit
L = Low voltage (1.35v)
Blank or omitted = Standard
10600 = 1333-MHz
8500 = 1066-MHz
6
DIMM type R = RDIMM (registered)
E = UDIMM (unbuffered with ECC)
For the latest supported memory information, see the QuickSpecs on the HP website ( http://www.hp.com
).
UDIMM maximum memory configurations
The server supports a maximum of 32 GB, using 1-GB, 2-GB, 4-GB and 8-GB single-rank or dual-rank
UDIMMs.
Hardware options installation 29
Memory configuration
To optimize server availability, the server supports ECC memory. ECC memory provides the greatest memory capacity for a given DIMM size, while providing single-bit memory error corrections, depending on the specific DIMM type. This mode is the default option for this server.
For the latest memory configuration information, see the QuickSpecs on the HP website
( http://www.hp.com
).
ECC memory configuration
ECC memory is the default memory protection mode for this server. Standard ECC can correct single-bit memory errors and detect multi-bit memory errors. When multi-bit errors are detected by using Standard
ECC, the error is sent to the server and causes the server to halt.
General DIMM slot population guidelines
•
The server has four memory slots.
•
The server supports two channels with two UDIMM slots per channel.
•
Memory channel A consists of the two UDIMMs that are closest to the processor.
•
Memory channel B consists of the two UDIMMs that are located farthest from the processor.
•
Different types of processors have different types of memory support.
•
The server supports dual-rank, 1,333 MT/s ECC UDIMMs.
•
The server supports up to 32 GB (4×8-GB) for UDIMMs.
•
The server does not support: o
LV-DIMMs o o
RDIMMs
Non-ECC UDIMMs
•
When installing DIMMs: o
If the processor is not installed, then do not install DIMMs. o o o
Populate DIMMs from heaviest load (double-rank) to lightest load (single-rank).
Use HP-qualified UDIMMs.
The DIMM farthest from the processor (either CHA or CHB) must be populated first.
Installing a DIMM
1.
2.
3.
4.
Power down the server (on page 17 ).
Remove the access panel (on page 18 ).
Remove the air baffle (on page 19 ).
Open the DIMM slot latches.
Hardware options installation 30
5.
Install the DIMM.
6.
7.
Install the air baffle (on page 20 ).
Install the access panel (on page 18 ).
If you are installing DIMMs in Lockstep configuration, configure the mode in RBSU (» HP ROM-Based Setup
Utility » on page 54 ).
Drive options
The server provides non-hot-plug capability through an embedded SATA controller. To obtain hot-plug capability, install an optional controller and hot-plug cable option kit.
Drive guidelines
When adding drives to the server, observe the following general guidelines:
•
The system automatically sets all drive numbers.
•
If only one drive is used, install it in the bay with the lowest drive number.
•
Drives must be the same capacity to provide the greatest storage space efficiency when drives are grouped together into the same drive array.
Optional storage controllers provide support for hot-plug capability and drive LEDs. Controller options are:
•
The embedded controller supports non-hot-plug SATA drives. Drive LEDs are not supported.
•
Optional SATA controllers support hot-plug SATA drives and drive LEDs.
•
Optional SAS controllers support hot-plug SAS or SATA drives and drive LEDs.
Removing a drive blank
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.
Hardware options installation 31
Remove the component as indicated.
Removing a drive
IMPORTANT: Hot-plug capability and drive LED support are only available when a supported optional controller is installed in the server.
To remove the component:
1.
Back up all server data on the drive.
2.
Power down the server (on page 17 ).
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.
3.
Remove the drive.
Hardware options installation 32
Installing a hot-plug drive
IMPORTANT: Hot-plug capability and drive LED support are only available when a supported optional controller is installed in the server.
1.
2.
3.
Power down the server (on page 17 ).
Remove the existing drive blank (» Removing a drive blank » on page 31 ).
Prepare the drive.
4.
Install the drive.
Optical drive option
To install the component:
1.
Power down the server (on page 17 ).
2.
Remove the server from the rack (on page 17 ).
Hardware options installation 33
3.
4.
5.
Remove the access panel (on page 18 ).
Remove the air baffle (on page 19 ).
Remove the 9.5-mm optical drive blank. Retain the blank for future use.
6.
Install the 9.5-mm optical drive assembly. When fully inserted, the assembly locking latch clicks.
7.
Using a T-15 Torx screwdriver, secure the drive to the chassis.
Hardware options installation 34
8.
Connect the optical drive and power cable to the optical drive.
11.
12.
13.
14.
9.
10.
Connect the power connector to the power supply backplane.
Connect the SATA cable to the system board. See the cabling section for correct cable routing (» Optical drive cabling » on page 51 ).
Install the air baffle (on page 20 ).
Install the access panel (on page 18 ).
Install the server into the rack (» Installing the server into the rack » on page 25 ).
Power up the server (» Powering up and configuring the server » on page 26
, on page 17 ).
Dedicated iLO management port module option
To install the component:
1.
Power down the server (on page 17 ).
2.
3.
4.
Remove the server from the rack (on page 17 ).
Remove the access panel (on page 18 ).
Remove the air baffle (on page 19 ).
Hardware options installation 35
5.
Press the knockout.
6.
7.
To remove the knockout from the chassis, twist and pull it.
Using a T-15 Torx screwdriver, install the dedicated iLO management port module.
8.
9.
10.
11.
Install the air baffle (on page 20 ).
Install the access panel (on page 18 ).
Install the server into the rack (» Installing the server into the rack » on page 25 ).
Power up the server (» Powering up and configuring the server » on page 26
, on page 17 ).
Expansion board option
To install the component:
1.
Power down the server (on page 17 ).
2.
Remove the server from the rack (on page 17 ).
Hardware options installation 36
3.
4.
5.
6.
Remove the access panel (on page 18 ).
Disconnect all internal cables connected to any existing expansion boards.
Remove the PCIe riser cage (on page 18 ).
Remove the expansion slot covers.
7.
Install the expansion board.
IMPORTANT: The server does not power up if the PCIe riser board assembly is not seated properly.
8.
9.
10.
11.
12.
Install the PCIe riser cage (on page 19 ).
Connect all internal cables for expansion boards.
Install the access panel (on page 18 ).
Install the server into the rack (» Installing the server into the rack » on page 25 ).
Power up the server (» Powering up and configuring the server » on page 26
, on page 17 ).
Storage controller option
IMPORTANT: For additional installation and configuration information, see the documentation that ships with the option.
To install the component:
1.
2.
Power down the server (on page 17 ).
Remove the server from the rack (on page 17 ).
3.
4.
5.
Remove the access panel (on page 18 ).
Remove the PCIe riser cage (on page 18 ).
Remove the drive cables (» Cabling » on page 48 ).
Hardware options installation 37
6.
7.
Install the storage controller.
Connect the storage controller cable to the controller and to the drive backplane.
See the server installation sheet and the documentation that ships with the storage controller.
IMPORTANT: The server does not power up if the PCI riser board assembly is not seated properly.
8.
9.
10.
11.
Install the PCIe riser cage (on page 19 ).
Install the access panel (on page 18 ).
Install the server into the rack (» Installing the server into the rack » on page 25 ).
Power up the server (» Powering up and configuring the server » on page 26
, on page 17 ).
BBWC module and battery pack option
CAUTION: To prevent a server malfunction or damage to the equipment, do not add or remove the battery pack while an array capacity expansion, RAID level migration, or stripe size migration is in progress.
CAUTION: After the server is powered down, wait 15 seconds and then check the amber LED before unplugging the cable from the cache module. If the amber LED blinks after 15 seconds, do not remove the cable from the cache module. The cache module is backing up data, and data is lost if the cable is detached.
IMPORTANT: The battery pack might have a low charge when installed. In this case, a POST error message is displayed when the server is powered up, indicating that the battery pack is temporarily disabled. No action is necessary on your part. The internal circuitry automatically recharges the batteries and enables the battery pack. This process might take up to four hours.
During this time, the cache module functions properly, but without the performance advantage of the battery pack.
NOTE: The data protection and the time limit also apply if a power outage occurs. When power is restored to the system, an initialization process writes the preserved data to the hard drives.
To install the component:
1.
2.
3.
Power down the server (on page 17 ).
Remove the server from the rack (on page 17 ).
Remove the access panel (on page 18 ).
4.
5.
Remove the PCIe riser cage (on page 18 ).
Install the storage controller, if not installed (» Storage controller option » on page 37 ).
Hardware options installation 38
6.
Install the cache module on the controller.
7.
Connect the battery pack cable to the cache module.
Hardware options installation 39
8.
Install the battery pack.
9.
10.
11.
12.
13.
Route the cable (» BBWC battery cabling » on page 50 ).
Install the PCIe riser cage (on page 19 ).
Install the access panel (on page 18 ).
Install the server into the rack (» Installing the server into the rack » on page 25 ).
Power up the server (» Powering up and configuring the server » on page 26
, on page 17 ).
Redundant hot-plug power supply option (with cage)
To install the component:
1.
2.
Power down the server (on page 17 ).
Remove all power: a. b.
Disconnect each power cord from the power source.
Disconnect each power cord from the server.
3.
4.
5.
6.
7.
8.
9.
Remove the server from the rack (on page 17 ).
Remove the access panel (on page 18 ).
Remove the air baffle (on page 19 ).
Remove the PCIe riser cage (on page 18 ).
Disconnect any power cables connected to the front drive cage.
Remove all cables connected to the system board.
Remove the system board.
Hardware options installation 40
10.
Remove the rear bracket.
11.
Remove the ATX power supply.
Hardware options installation 41
12.
Install the redundant power supply cage.
13.
14.
15.
16.
17.
18.
Install the system board.
Connect all cables previously disconnected from the system board.
Route and connect power cables to the system board and the front drive cage.
Install the PCIe riser cage (on page 19 ).
Install the air baffle (on page 20 ).
Install the foam air baffle from the option kit:
IMPORTANT: Two foam air baffles are provided in the option kit. The shorter foam air baffle is designed to be installed in servers with a four-bay LFF drive cage configuration. The longer foam air baffle is designed to be installed in servers with an eight-bay SFF drive cage configuration.
Depending on the server configuration, be sure to install the correct foam air baffle. o
Foam air baffle for a four-bay LFF drive cage
Hardware options installation 42
o
Foam air baffle for an eight-bay SFF drive cage
19.
20.
21.
Install the access panel (on page 18 ).
Install the server into the rack (» Installing the server into the rack » on page 25 ).
Depending on the configuration, install either two power supplies, or one power supply blank and one power supply. o
Power supply blank
Hardware options installation 43
o
Power supply
22.
23.
24.
Connect the power cord to the power supply.
Connect the power cord to the power source.
Power up the server (» Powering up and configuring the server » on page 26
, on page 17 ).
HP Trusted Platform Module option
Use these instructions to install and enable a TPM on a supported server. This procedure includes three sections:
1.
Installing the Trusted Platform Module board (on page 45 ).
2.
3.
Retaining the recovery key/password (on page 46 ).
Enabling the Trusted Platform Module (on page 46 ).
Enabling the TPM requires accessing RBSU (» HP ROM-Based Setup Utility » on page 54 ). For more
information about RBSU, see the HP website ( http://www.hp.com/go/ilomgmtengine/docs ).
TPM installation requires the use of drive encryption technology, such as the Microsoft Windows BitLocker
Drive Encryption feature. For more information on BitLocker, see the Microsoft website
( http://www.microsoft.com
).
CAUTION: Always observe the guidelines in this document. Failure to follow these guidelines can cause hardware damage or halt data access.
When installing or replacing a TPM, observe the following guidelines:
•
Do not remove an installed TPM. Once installed, the TPM becomes a permanent part of the system board.
•
When installing or replacing hardware, HP service providers cannot enable the TPM or the encryption technology. For security reasons, only the customer can enable these features.
•
When returning a system board for service replacement, do not remove the TPM from the system board.
When requested, HP Service provides a TPM with the spare system board.
•
Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data.
Hardware options installation 44
•
When using BitLocker, always retain the recovery key/password. The recovery key/password is required to enter Recovery Mode after BitLocker detects a possible compromise of system integrity.
•
HP is not liable for blocked data access caused by improper TPM use. For operating instructions, see the encryption technology feature documentation provided by the operating system.
Installing the Trusted Platform Module board
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power On/Standby button does not completely shut off system power. Portions of the power supply and some internal circuitry remain active until AC power is removed.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
1.
2.
3.
4.
Power down the server (on page 17 ).
Remove the server from the rack, if necessary (» Remove the server from the rack » on page 17 ).
Place the server on a flat, level work surface.
Remove the access panel (on page 18 ).
CAUTION: Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data.
5.
Install the TPM board. Press down on the connector to seat the board.
Hardware options installation 45
6.
Install the TPM security rivet by pressing the rivet firmly into the system board.
7.
8.
9.
Install the access panel (on page 18 ).
Install the server into the rack (» Installing the server into the rack » on page 25 ).
Power up the server (» Powering up and configuring the server » on page 26
, on page 17 ).
Retaining the recovery key/password
The recovery key/password is generated during BitLocker™ setup, and can be saved and printed after
BitLocker™ is enabled. When using BitLocker™, always retain the recovery key/password. The recovery key/password is required to enter Recovery Mode after BitLocker™ detects a possible compromise of system integrity.
To help ensure maximum security, observe the following guidelines when retaining the recovery key/password:
•
Always store the recovery key/password in multiple locations.
•
Always store copies of the recovery key/password away from the server.
•
Do not save the recovery key/password on the encrypted hard drive.
Enabling the Trusted Platform Module
1.
When prompted during the start-up sequence, access RBSU by pressing the F9 key.
2.
3.
4.
5.
6.
7.
8.
From the Main Menu, select Server Security.
From the Server Security Menu, select Trusted Platform Module.
From the Trusted Platform Module Menu, select TPM Functionality.
Select Enable, and then press the Enter key to modify the TPM Functionality setting.
Press the Esc key to exit the current menu, or press the F10 key to exit RBSU.
Reboot the server.
Enable the TPM in the OS. For OS-specific instructions, see the OS documentation.
Hardware options installation 46
CAUTION: When a TPM is installed and enabled on the server, data access is locked if you fail to follow the proper procedures for updating the system or option firmware, replacing the system board, replacing a hard drive, or modifying OS application TPM settings.
For more information on firmware updates and hardware procedures, see the HP Trusted Platform Module
Best Practices White Paper on the HP website ( http://www.hp.com/support ).
For more information on adjusting TPM usage in BitLocker™, see the Microsoft website
( http://technet.microsoft.com/en-us/library/cc732774.aspx
).
Hardware options installation 47
Cabling
Cabling overview
This section provides guidelines that help you make informed decisions about cabling the server and hardware options to optimize performance.
Server cabling
CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinched or air flow can be blocked.
IMPORTANT: Route the cables without blocking the airflow or other installed components. Use the cable clips installed in the chassis to manage cable routing.
Nonredundant power supply cabling
Cabling 48
Redundant power supply cabling
Internal USB cabling
Cabling 49
BBWC battery cabling
•
The Smart Array controller full height full length slot
•
The Smart Array controller low profile slot
Cabling 50
Optical drive cabling
SATA cabling
•
LFF model
Cabling 51
•
SFF model
SAS cabling
•
LFF model
Cabling 52
•
SFF model
Cabling 53
Configuration and utilities
Configuration tools
SmartStart software
SmartStart is a collection of software that optimizes single-server setup, providing a simple and consistent way to deploy server configuration. SmartStart has been tested on many ProLiant server products, resulting in proven, reliable configurations.
SmartStart assists the deployment process by performing a wide range of configuration activities, including:
•
Preparing the system for installing «off-the-shelf» versions of leading operating system software
•
Installing optimized server drivers, management agents, and utilities automatically with every assisted installation
•
Testing server hardware using the Insight Diagnostics Utility (» HP Insight Diagnostics » on page 59 )
•
Installing software drivers directly from the CD. With systems that have Internet connection, the
SmartStart Autorun Menu provides access to a complete list of ProLiant system software.
•
Enabling access to the Array Configuration Utility and Erase Utility (on page 59 )
SmartStart is included in the HP Insight Foundation suite for ProLiant. For more information about SmartStart software, see the HP Insight Foundation suite for ProLiant or the HP website
( http://www.hp.com/go/foundation ).
SmartStart Scripting Toolkit
The SmartStart Scripting Toolkit is a server deployment product that allows you to build an unattended automated installation for high-volume server deployments. The SmartStart Scripting Toolkit is designed to support ProLiant BL, ML, DL, and SL servers. The toolkit includes a modular set of utilities and important documentation that describes how to apply these tools to build an automated server deployment process.
The Scripting Toolkit provides a flexible way to create standard server configuration scripts. These scripts are used to automate many of the manual steps in the server configuration process. This automated server configuration process cuts time from each deployment, making it possible to scale rapid, high-volume server deployments.
For more information, and to download the SmartStart Scripting Toolkit, see the HP website
( http://www.hp.com/servers/sstoolkit ).
HP ROM-Based Setup Utility
RBSU is a configuration utility embedded in HP ProLiant servers that performs a wide range of configuration activities that can include the following:
•
Configuring system devices and installed options
•
Enabling and disabling system features
Configuration and utilities 54
•
Displaying system information
•
Selecting the primary boot controller
•
Configuring memory options
•
Language selection
For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website ( http://www.hp.com/support/smartstart/documentation ).
Using RBSU
To use RBSU, use the following keys:
•
To access RBSU, press the F9 key during power-up when prompted.
•
To navigate the menu system, use the arrow keys.
•
To make selections, press the Enter key.
•
To access Help for a highlighted configuration option, press the F1 key.
IMPORTANT: RBSU automatically saves settings when you press the Enter key. The utility does not prompt you for confirmation of settings before you exit the utility. To change a selected setting, you must select a different setting and press the Enter key.
Default configuration settings are applied to the server at one of the following times:
•
Upon the first system power-up
•
After defaults have been restored
Default configuration settings are sufficient for proper typical server operation, but configuration settings can be modified using RBSU. The system will prompt you for access to RBSU with each power-up.
Auto-configuration process
The auto-configuration process automatically runs when you boot the server for the first time. During the power-up sequence, the system ROM automatically configures the entire system without needing any intervention. During this process, the ORCA utility, in most cases, automatically configures the array to a default setting based on the number of drives connected to the server.
NOTE: The server may not support all the following examples.
NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not automatically configure the array. You must run ORCA to configure the array settings.
Drives installed
1
2
3, 4, 5, or 6
More than 6
Drives used
1
2
3, 4, 5, or 6
0
RAID level
RAID 0
RAID 1
RAID 5
None
To change any ORCA default settings and override the auto-configuration process, press the F8 key when prompted.
Configuration and utilities 55
For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website ( http://www.hp.com/support/smartstart/documentation ).
Boot options
Near the end of the boot process, the boot options screen is displayed. This screen is visible for several seconds before the system attempts to boot from a supported boot device. During this time, you can do the following:
•
Access RBSU by pressing the F9 key.
•
Access the System Maintenance Menu (which enables you to launch ROM-based Diagnostics or
Inspect) by pressing the F10 key.
•
Access the boot menu by pressing the F11 key.
•
Force a PXE Network boot by pressing the F12 key.
BIOS Serial Console
BIOS Serial Console allows you to configure the serial port to view POST error messages and run RBSU remotely through a serial connection to the server COM port. The server that you are remotely configuring does not require a keyboard and mouse.
For more information about BIOS Serial Console, see the BIOS Serial Console User Guide on the
Documentation CD or the HP website ( http://www.hp.com/support/smartstart/documentation ).
Array Configuration Utility
ACU is a browser-based utility with the following features:
•
Runs as a local application or remote service
•
Supports online array capacity expansion, logical drive extension, assignment of online spares, and
RAID or stripe size migration
•
Suggests the optimum configuration for an unconfigured system
•
Provides different operating modes, enabling faster configuration or greater control over the configuration options
•
Remains available any time that the server is on
•
Displays on-screen tips for individual steps of a configuration procedure
•
Beginning with ACU version 8.28.13.0, provides diagnostic functionality on the Diagnostics tab
(formerly known as Array Diagnostics Utility).
For optimum performance, the minimum display settings are 1024 × 768 resolution and 16-bit color. Servers running Microsoft® operating systems require one of the following supported browsers:
•
Internet Explorer 6.0 or later
•
Mozilla Firefox 2.0 or later
For Linux servers, see the README.TXT file for additional browser and support information.
For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant
Servers User Guide on the HP website ( http://www.hp.com/support/SAC_UG_ProLiantServers_en ). To
Configuration and utilities 56
configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website ( http://www.hp.com/support/CASAC_RG_en ).
Option ROM Configuration for Arrays
Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign
RAID levels, and establish online spare configurations.
The utility also provides support for the following functions:
•
Reconfiguring one or more logical drives
•
Viewing the current logical drive configuration
•
Deleting a logical drive configuration
•
Setting the controller to be the boot controller
•
Selecting the boot volume
If you do not use the utility, ORCA will default to the standard configuration.
For more information regarding the default configurations that ORCA uses, see the HP ROM-Based Setup
Utility User Guide on the Documentation CD.
For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant
Servers User Guide on the HP website ( http://www.hp.com/support/SAC_UG_ProLiantServers_en ). To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website ( http://www.hp.com/support/CASAC_RG_en ).
Re-entering the server serial number and product ID
After you replace the system board, you must re-enter the server serial number and the product ID.
1.
2.
3.
During the server startup sequence, press the F9 key to access RBSU.
Select the Advanced Options menu.
Select Service Options.
4.
5.
6.
7.
8.
9.
10.
11.
Select Serial Number. The following warnings appear:
WARNING! WARNING! WARNING! The serial number is loaded into the system during the manufacturing process and should NOT be modified. This option should only be used by qualified service personnel. This value should always match the serial number sticker located on the chassis.
Warning: The serial number should ONLY be modified by qualified personnel.
This value should always match the serial number located on the chassis.
Press the Enter key to clear the warning.
Enter the serial number and press the Enter key.
Select Product ID. The following warning appears:
Warning: The Product ID should ONLY be modified by qualified personnel. This value should always match the Product ID on the chassis.
Enter the product ID and press the Enter key.
Press the Esc key to close the menu.
Press the Esc key to exit RBSU.
Press the F10 key to confirm exiting RBSU. The server automatically reboots.
Configuration and utilities 57
Management tools
Automatic Server Recovery
ASR is a feature that causes the system to restart when a catastrophic operating system error occurs, such as a blue screen, ABEND (does not apply to HP ProLiant DL980 Servers), or panic. A system fail-safe timer, the
ASR timer, starts when the System Management driver, also known as the Health Driver, is loaded. When the operating system is functioning properly, the system periodically resets the timer. However, when the operating system fails, the timer expires and restarts the server.
ASR increases server availability by restarting the server within a specified time after a system hang. At the same time, the HP SIM console notifies you by sending a message to a designated pager number that ASR has restarted the system. You can disable ASR from the System Management Homepage or through RBSU.
ROMPaq utility
The ROMPaq utility enables you to upgrade the system firmware (BIOS). To upgrade the firmware, insert a
ROMPaq USB Key into an available USB port and boot the system. In addition to ROMPaq, Online Flash
Components for Windows and Linux operating systems are available for updating the system firmware.
The ROMPaq utility checks the system and provides a choice (if more than one exists) of available firmware revisions.
For more information, go to the HP website ( http://www.hp.com/go/hpsc ) and click on Drivers, Software
& Firmware. Then, enter your product name in the Find an HP product field and click Go.
Integrated Lights-Out 3 technology
The iLO 3 subsystem is a standard component of selected ProLiant servers that provides server health and remote server manageability. The iLO 3 subsystem includes an intelligent microprocessor, secure memory, and a dedicated network interface. This design makes iLO 3 independent of the host server and its operating system.
In addition to remote management features, iLO 3 is also responsible for managing the health of the ProLiant server. The intelligence of iLO 3 manages the Sea of Sensors thermal control, directs power management functions, and monitors the health of server components.
The iLO 3 subsystem provides secure remote access from any authorized network client. The enhancements to iLO 3 enable customers to get work done faster by providing turbo-charged remote access performance, a streamlined user experience, and enhanced standards support.
Using iLO 3, you can do the following:
•
Access a high-performance and secure Remote Console to the server from anywhere in the world.
•
Use the shared iLO 3 Remote Console to collaborate with up to six server administrators.
•
Remotely mount high-performance Virtual Media devices to the server.
•
Securely and remotely control the power state of the managed server.
•
Send alerts from iLO 3 regardless of the state of the host server.
•
Access advanced troubleshooting features through the iLO 3 interface.
Configuration and utilities 58
For more information about iLO 3 features (which may require an iLO Advanced Pack or iLO Advanced for
BladeSystem license), see the iLO 3 documentation on the Documentation CD or on the HP website
( http://www.hp.com/go/ilo ).
Erase Utility
CAUTION: Perform a backup before running the System Erase Utility. The utility sets the system to its original factory state, deletes the current hardware configuration information, including array setup and disk partitioning, and erases all connected hard drives completely. Refer to the instructions for using this utility.
Run the Erase Utility if you must erase the system for the following reasons:
•
You want to install a new operating system on a server with an existing operating system.
•
You encounter an error when completing the steps of a factory-installed operating system installation.
To access the Erase Utility, use the System Erase button on the home screen of the SmartStart CD (» SmartStart software » on page 54 ).
USB support
HP provides both standard USB 2.0 support and legacy USB 2.0 support. Standard support is provided by the OS through the appropriate USB device drivers. Before the OS loads, HP provides support for USB devices through legacy USB support, which is enabled by default in the system ROM.
Legacy USB support provides USB functionality in environments where USB support is not available normally.
Specifically, HP provides legacy USB functionality for the following:
•
POST
•
RBSU
•
Diagnostics
•
DOS
•
Operating environments which do not provide native USB support
Diagnostic tools
HP Insight Diagnostics
HP Insight Diagnostics is a proactive server management tool, available in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify server installations, troubleshoot problems, and perform repair validation.
HP Insight Diagnostics Offline Edition performs various in-depth system and component testing while the OS is not running. To run this utility, launch the SmartStart CD.
HP Insight Diagnostics Online Edition is a web-based application that captures system configuration and other related data needed for effective server management. Available in Microsoft® Windows® and Linux versions, the utility helps to ensure proper system operation.
For more information or to download the utility, refer to the HP website ( http://www.hp.com/servers/diags ).
Configuration and utilities 59
HP Insight Diagnostics survey functionality
HP Insight Diagnostics (on page 59 ) provides survey functionality that gathers critical hardware and software
information on ProLiant servers.
This functionality supports operating systems that may not be supported by the server. For operating systems supported by the server, see the HP website ( http://www.hp.com/go/supportos ).
If a significant change occurs between data-gathering intervals, the survey function marks the previous information and overwrites the survey data files to reflect the latest changes in the configuration.
Survey functionality is installed with every SmartStart-assisted HP Insight Diagnostics installation, or it can be
installed through the HP PSP (» ProLiant Support Packs » on page 62 ).
NOTE: The current version of SmartStart provides the memory spare part numbers for the server.
To download the latest version, see the HP website ( http://www.hp.com/support ).
Integrated Management Log
The IML records hundreds of events and stores them in an easy-to-view form. The IML timestamps each event with 1-minute granularity.
You can view recorded events in the IML in several ways, including the following:
•
From within HP SIM
•
From within Survey Utility
•
From within operating system-specific IML viewers o
For NetWare: IML Viewer (does not apply to HP ProLiant DL980 Servers) o o
For Windows®: IML Viewer
For Linux: IML Viewer Application
•
From within the iLO 3 user interface
•
From within HP Insight Diagnostics (on page 59 )
For more information, see the Management CD or DVD in the HP Insight Foundation suite for ProLiant.
Remote support and analysis tools
HP Insight Remote Support software
HP strongly recommends that you install HP Insight Remote Support software to complete the installation or upgrade of your product and to enable enhanced delivery of your HP Warranty, HP Care Pack Service, or
HP contractual support agreement. HP Insight Remote Support supplements your monitoring 24 x 7 to ensure maximum system availability by providing intelligent event diagnosis, and automatic, secure submission of hardware event notifications to HP, which will initiate a fast and accurate resolution, based on your product’s service level. Notifications may be sent to your authorized HP Channel Partner for on-site service, if configured and available in your country. The software is available in two variants:
•
HP Insight Remote Support Standard: This software supports server and storage devices and is optimized for environments with 1–50 servers. Ideal for customers who can benefit from proactive notification but do not need proactive service delivery and integration with a management platform.
Configuration and utilities 60
•
HP Insight Remote Support Advanced: This software provides comprehensive remote monitoring and proactive service support for nearly all HP servers, storage, network, and SAN environments, plus selected non-HP servers that have a support obligation with HP. It is integrated with HP Systems Insight
Manager. A dedicated server is recommended to host both HP Systems Insight Manager and HP Insight
Remote Support Advanced.
Details for both versions are available on the HP website ( http://www.hp.com/go/insightremotesupport ).
To download the software, go to Software Depot ( http://www.software.hp.com
).
Select Insight Remote Support from the menu on the right.
Keeping the system current
Drivers
IMPORTANT: Always perform a backup before installing or updating device drivers.
The server includes new hardware that may not have driver support on all OS installation media.
If you are installing a SmartStart-supported OS, use the SmartStart software (on page 54 ) and its Assisted
Path feature to install the OS and latest driver support.
If you are installing drivers from the SmartStart CD, be sure that you are using the latest SmartStart version that your server supports. To verify that your server is using the latest supported version, see the HP website
( http://www.hp.com/support ). For more information, see the documentation provided with the SmartStart
CD.
If you do not use the SmartStart CD to install an OS, drivers for some of the new hardware are required.
These drivers, as well as other option drivers, ROM images, and value-add software can be downloaded from the HP website ( http://www.hp.com/support ).
To directly locate the OS drivers for a particular server, enter the following web address into the browser: http://www.hp.com/support/<servername>
In place of <servername>, enter the server name.
For example: http://www.hp.com/support/dl360g6 ( http://www.hp.com/support/dl360g6 )
Version control
The VCRM and VCA are Web-enabled Insight Management Agents tools that HP SIM uses to facilitate and schedule software update tasks to the entire enterprise.
•
VCRM manages the repository for Windows and Linux PSPs as well as online firmware. Administrators can browse a graphical view of the PSPs or configure VCRM to automatically update the repository with
Internet downloads of the latest software from HP.
•
VCA compares installed software versions and available updates. Administrators can configure VCA to point to a repository managed by VCRM.
Configuration and utilities 61
For more information about version control tools, see the HP Systems Insight Manager Help Guide and the
Version Control User Guide on the HP Systems Insight Manager website ( http://www.hp.com/go/hpsim ).
ProLiant Support Packs
PSPs represent operating system-specific bundles of ProLiant optimized drivers, utilities, and management agents. Refer to the PSP website ( http://h18000.www1.hp.com/products/servers/management/psp.html
).
Operating System Version Support
For information about specific versions of a supported operating system, refer to the operating system support matrix ( http://www.hp.com/go/supportos ).
Firmware
The Smart Update Firmware DVD is an organized firmware collection for ProLiant servers and options
powered by HP Smart Update Manager (on page 62 ). The Smart Update Firmware DVD combines the
following resources on a single DVD:
•
Firmware Maintenance CD
•
HP BladeSystem Firmware Deployment Tool (FDT)
•
The HP BladeSystem online firmware bundles
•
The ProLiant BladeSystem Release Sets
•
Offline, automatic mode for HP ProLiant BL, DL, ML, and 100 Series servers
•
Firmware deployment support for HP ProLiant 100 Series servers
HP Smart Update Manager
The HP Smart Update Manager provides intelligent and flexible firmware and software deployment. This technology assists in reducing the complexity of provisioning and updating HP ProLiant Servers, options, and
Blades within the data center. HP SUM is delivered on the Smart Update Firmware DVD, ProLiant Support
Packs, and Easy Set-up CDs.
HP SUM enables system administrators to upgrade ROM images efficiently across a wide range of servers and options. This tool has the following features:
•
Enables GUI and a command-line, scriptable interface
•
Enables scriptable, command-line deployment
•
Requires no agent for remote installations
•
Enables dependency checking, which ensures appropriate install order and dependency checking between components
•
Deploys software and firmware on Windows and Linux operating systems
•
Performs local or remote (one-to-many) online deployment
•
Deploys firmware and software together
•
Supports offline and online deployment
•
Deploys necessary component updates only
Configuration and utilities 62
•
Downloads the latest components from Web
•
Enables direct update of BMC firmware (iLO and LO100i)
For more information about HP SUM and to access the HP Smart Update Manager User Guide, see the HP website ( http://www.hp.com/go/hpsum/documentation ).
Change control and proactive notification
HP offers Change Control and Proactive Notification to notify customers 30 to 60 days in advance of upcoming hardware and software changes on HP commercial products.
For more information, refer to the HP website ( http://www.hp.com/go/pcn ).
Care Pack
HP Care Pack Services offer upgraded service levels to extend and expand bundled services with easy-to-buy, easy-to-use support packages that help you make the most of your server investments. For more information, see the HP website ( http://www.hp.com/services/carepack ).
Configuration and utilities 63
Troubleshooting
Pre-diagnostic steps
WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before removing, replacing, reseating, or modifying system components.
IMPORTANT: This guide provides information for multiple servers. Some information may not apply to the server you are troubleshooting. Refer to the server documentation for information on procedures, hardware options, software tools, and operating systems supported by the server.
1.
2.
3.
4.
Review the important safety information (on page 64 ).
Gather symptom information (on page 66 ).
Prepare the server for diagnosis (on page 66 ).
Use the Start diagnosis flowchart (on page 69 ) to begin the diagnostic process.
Important safety information
Familiarize yourself with the safety information in the following sections before troubleshooting the server.
Important safety information
Before servicing this product, read the Important Safety Information document provided with the server.
Symbols on equipment
The following symbols may be placed on equipment to indicate the presence of potentially hazardous conditions.
This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel.
This symbol indicates the presence of electric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure.
This symbol on an RJ-45 receptacle indicates a network interface connection.
WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into this receptacle.
Troubleshooting 64
This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching.
14.26 kg
31.4 lb
This symbol indicates that the component exceeds the recommended weight for one individual to handle safely.
WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manual material handling.
These symbols, on power supplies or systems, indicate that the equipment is supplied by multiple sources of power.
WARNING: To reduce the risk of injury from electric shock, remove all power cords to completely disconnect power from the system.
Warnings and cautions
WARNING: Only authorized technicians trained by HP should attempt to repair this equipment.
All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard.
WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that:
•
The leveling feet are extended to the floor.
•
The full weight of the rack rests on the leveling feet.
• The stabilizing feet are attached to the rack if it is a single-rack installation.
• The racks are coupled together in multiple-rack installations.
•
Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason.
WARNING: To reduce the risk of electric shock or damage to the equipment:
• Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
•
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
• Unplug the power cord from the power supply to disconnect power to the equipment.
•
Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server.
Troubleshooting 65
14.26 kg
31.4 lb
WARNING: To reduce the risk of personal injury or damage to the equipment:
•
Observe local occupation health and safety requirements and guidelines for manual handling.
• Obtain adequate assistance to lift and stabilize the chassis during installation or removal.
•
The server is unstable when not fastened to the rails.
• When mounting the server in a rack, remove the power supplies and any other removable module to reduce the overall weight of the product.
CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the front and back of the server.
CAUTION: The server is designed to be electrically grounded (earthed). To ensure proper operation, plug the AC power cord into a properly grounded AC outlet only.
Symptom information
Before troubleshooting a server problem, collect the following information:
•
What events preceded the failure? After which steps does the problem occur?
•
What has been changed since the time the server was working?
•
Did you recently add or remove hardware or software? If so, did you remember to change the appropriate settings in the server setup utility, if necessary?
•
How long has the server exhibited problem symptoms?
•
If the problem occurs randomly, what is the duration or frequency?
To answer these questions, the following information may be useful:
•
Run HP Insight Diagnostics (on page 59 ) and use the survey page to view the current configuration or
to compare it to previous configurations.
•
Refer to your hardware and software records for information.
•
Refer to server LEDs and their statuses.
Prepare the server for diagnosis
1.
2.
3.
4.
5.
Be sure the server is in the proper operating environment with adequate power, air conditioning, and humidity control. For required environmental conditions, see the server documentation.
Record any error messages displayed by the system.
Remove all diskettes, CD-ROMs, DVD-ROMs, and USB drive keys.
Power down the server and peripheral devices if you will be diagnosing the server offline. If possible, always perform an orderly shutdown: a. b.
Exit any applications.
Exit the operating system. c.
Power down the server (on page 17 ).
Disconnect any peripheral devices not required for testing (any devices not necessary to power up the server). Do not disconnect the printer if you want to use it to print error messages.
Troubleshooting 66
6.
Collect all tools and utilities, such as a Torx screwdriver, loopback adapters, ESD wrist strap, and software utilities, necessary to troubleshoot the problem. o
You must have the appropriate Health Drivers and Management Agents installed on the server. o o
To verify the server configuration, connect to the System Management Homepage
( http://h18013.www1.hp.com/products/servers/management/agents/index.html ) and select
Version Control Agent. The VCA gives you a list of names and versions of all installed HP drivers,
Management Agents, and utilities, and whether they are up-to-date.
HP recommends you have access to the server documentation for server-specific information.
HP recommends you have access to the SmartStart CD for value-added software and drivers required during the troubleshooting process. Download the current version of SmartStart from the
HP website ( http://www.hp.com/servers/smartstart ).
Performing processor procedures in the troubleshooting process
Before performing any troubleshooting steps that involve processors, review the following guidelines:
•
Be sure that only authorized personnel perform the troubleshooting steps that involve installing, removing, or replacing a processor.
•
Always locate the documentation for your processor model before performing any steps that require installing, removing, or replacing a processor. If you cannot locate the hard copy of the instructions that shipped with the processor, see the processor instructions in this document.
•
Some processor models require the use of a processor installation tool, and specific steps are documented to ensure that you do not damage the processor or processor socket on the system board.
For server models that have pins inside the processor socket, remember that THE PINS ON THE SYSTEM
BOARD ARE VERY FRAGILE AND EASILY DAMAGED. If you damage the socket, you must replace the system board.
•
Depending on the server model, the contacts may be on the processor or they may be inside the processor socket. Never touch the contacts. THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND
EASILY DAMAGED. If the contacts inside the processor socket are damaged, the system board must be replaced.
•
Always complete all other troubleshooting procedures before removing or replacing a processor.
Breaking the server down to the minimum hardware configuration
During the troubleshooting process, you may be asked to break the server down to the minimum hardware configuration. A minimum configuration consists of only the components needed to boot the server and successfully pass POST.
When requested to break the server down to the minimum configuration, uninstall the following components, if installed:
•
All additional DIMMs
Leave only the minimum required to boot the server—either one DIMM or a pair of DIMMs. For more information, see the memory guidelines in the server user guide.
•
All additional cooling fans, if applicable
For the minimum fan configuration, see the server user guide.
•
All additional power supplies, if applicable (leave one installed)
•
All hard drives
Troubleshooting 67
•
All optical drives (DVD-ROM, CD-ROM, and so forth)
•
All optional mezzanine cards
•
All expansion boards
Before removing the components, be sure to determine the minimum configuration for each component and follow all guidelines in the server user guide.
Always use the recommended minimum configuration above before removing any processors. If you are unable to isolate the issue with the configuration above, you will then remove all but one of the processors.
CAUTION: Before removing or replacing any processors, be sure to follow the guidelines
provided in «Performing processor procedures in the troubleshooting process (on page 67 ).»
Failure to follow the recommended guidelines can cause damage to the system board, requiring replacement of the system board.
Loose connections
Action:
•
Be sure all power cords are securely connected.
•
Be sure all cables are properly aligned and securely connected for all external and internal components.
•
Remove and check all data and power cables for damage. Be sure no cables have bent pins or damaged connectors.
•
If a fixed cable tray is available for the server, be sure the cords and cables connected to the server are routed correctly through the tray.
•
Be sure each device is properly seated. Avoid bending or flexing circuit boards when reseating components.
•
If a device has latches, be sure they are completely closed and locked.
•
Check any interlock or interconnect LEDs that may indicate a component is not connected properly.
•
If problems continue to occur, remove and reinstall each device, checking the connectors and sockets for bent pins or other damage.
•
For HP ProLiant BL c-Class Server Blades, be sure the OA tray is seated properly.
Service notifications
To view the latest service notifications, refer to the HP website ( http://www.hp.com/go/bizsupport ). Select the appropriate server model, and then click the Troubleshoot a Problem link on the product page.
Server health LEDs
Some servers have an internal health LED and an external health LED, while other servers have a single system health LED. The system health LED provides the same functionality as the two separate internal and external health LEDs. Depending on the model, the internal health LED and external health LED may either appear solid or they may flash. Both conditions represent the same symptom.
Troubleshooting 68
For the location of server LEDs and information on their statuses, see the server documentation on the HP website ( http://www.hp.com/support ).
Troubleshooting flowcharts
To effectively troubleshoot a problem, HP recommends that you start with the first flowchart in this section,
«Start diagnosis flowchart (on page 69 ),» and follow the appropriate diagnostic path. If the other flowcharts
do not provide a troubleshooting solution, follow the diagnostic steps in «General diagnosis flowchart (on
page 70 ).» The General diagnosis flowchart is a generic troubleshooting process to be used when the
problem is not server-specific or is not easily categorized into the other flowcharts.
The available flowcharts include:
•
Start diagnosis flowchart (on page 69 )
•
General diagnosis flowchart (on page 70 )
•
Server power-on problems flowchart (on page 72 )
•
POST problems flowchart (on page 75 )
•
OS boot problems flowchart (on page 77 )
•
Server fault indications flowchart (on page 78 )
Start diagnosis flowchart
Use the following flowchart to start the diagnostic process.
Item
1
See
«General diagnosis flowchart (on page 70 )»
2
3
«Power-on problems flowchart (» Server power-on problems flowchart » on page 72 )»
«POST problems flowchart (on page 75 )»
4
«OS boot problems flowchart (on page 77 )»
5
«Server fault indications flowchart (on page 78 )»
Troubleshooting 69
General diagnosis flowchart
1
2
The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of the problem, or if the other flowcharts do not fix the problem, use the following flowchart.
Item See
«Symptom information (on page 66 )»
«Loose connections (on page 68 )»
3
«Service notifications (on page 68 )»
4
The most recent version of a particular server or option firmware is available on the HP Support website ( http://www.hp.com/support ).
Troubleshooting 70
6
7
Item
5
8
9
10
See
«General memory problems are occurring» in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
Server maintenance and service guide, located on the Documentation CD or the HP website ( http://www.hp.com/products/servers/platforms )
•
«Hardware problems» in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see «Troubleshooting resources»
•
Server maintenance and service guide, located on the Documentation
CD or the HP website
( http://www.hp.com/products/servers/platforms )
«Breaking the server down to the minimum hardware configuration (on
page 67 )» or in the HP ProLiant Servers Troubleshooting Guide located on
the Documentation CD or see «Troubleshooting resources»
•
«Server information you need» in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
•
«Operating system information you need» in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
«HP contact information (on page 91 )»
Troubleshooting 71
Server power-on problems flowchart
Symptoms:
•
The server does not power on.
•
The system power LED is off or amber.
Troubleshooting 72
•
The external health LED is red or amber.
•
The internal health LED is red or amber.
NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation.
Possible causes:
•
Improperly seated or faulty power supply
•
Loose or faulty power cord
•
Power source problem
•
Power on circuit problem
•
Improperly seated component or interlock problem
•
Faulty internal component
Item
1
2
3
See
«Server health LEDs (on page 68 )» and «Component identification (on
page 7 )»
«HP Insight Diagnostics (on page 59 )» or in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
«Loose connections (on page 68 )»
4
5
6
7
8
Server maintenance and service guide, located on the Documentation CD, or the HP website ( http://www.hp.com/products/servers/platforms )
«Integrated Management Log (on page 60 )» or in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
«Power source problems» in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or see «Troubleshooting resources»
• «Power supply problems» in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see «Troubleshooting resources»
•
Server maintenance and service guide, located on the Documentation
CD, or the HP website
( http://www.hp.com/products/servers/platforms )
«System open circuits and short circuits» in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
Troubleshooting 73
Troubleshooting 74
POST problems flowchart
Symptoms:
•
Server does not complete POST
NOTE: The server has completed POST when the system attempts to access the boot device.
•
Server completes POST with errors
Possible problems:
•
Improperly seated or faulty internal component
•
Faulty KVM device
•
Faulty video device
Item See
1
2
«Video problems» in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or see «Troubleshooting resources»
KVM or iLO 3 documentation
3
«POST error messages and beep codes (on page 80 )»
4
«Symptom information (on page 66 )»
5
6
7
«Port 85 and iLO messages» in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see «Troubleshooting resources»
«Server health LEDs (on page 68 )» and «Component identification (on
page 7 )»
«Loose connections (on page 68 )»
8
9
«General memory problems are occurring» in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
Server maintenance and service guide, located on the Documentation CD or the HP website ( http://www.hp.com/products/servers/platforms ).
10
11
12
«Breaking the server down to the minimum hardware configuration (on
page 67 )» or in the HP ProLiant Servers Troubleshooting Guide located on
the Documentation CD or see «Troubleshooting resources»
•
«Hardware problems» in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see «Troubleshooting resources»
•
Server maintenance and service guide, located on the Documentation
CD or the HP website
( http://www.hp.com/products/servers/platforms )
«HP contact information (on page 91 )»
Troubleshooting 75
Item
13
See
•
«Server information you need» in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
•
«Operating system information you need» in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
Troubleshooting 76
OS boot problems flowchart
Symptoms:
•
Server does not boot a previously installed operating system
•
Server does not boot SmartStart
Possible causes:
•
Corrupted operating system
•
Hard drive subsystem problem
•
Incorrect boot order setting in RBSU
Item See
1
2
HP ROM-Based Setup Utility User Guide
(
http://www.hp.com/servers/smartstart
)
«POST problems flowchart (on page 75 )»
3
4
5
6
7
8
9
10
•
«Hard drive problems» in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see «Troubleshooting resources»
•
Controller documentation
«HP Insight Diagnostics (on page 59 )» or in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
•
«CD-ROM and DVD drive problems» in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
•
Controller documentation
•
«Loose connections (on page 68 )»
«General memory problems are occurring» in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
•
«Operating system problems» in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
•
«HP contact information (on page 91 )»
«Breaking the server down to the minimum hardware configuration (on
page 67 )» in the HP ProLiant Servers Troubleshooting Guide located on the
Documentation CD or see «Troubleshooting resources»
•
«Hardware problems» in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see «Troubleshooting resources»
•
Server maintenance and service guide, located on the Documentation
CD or the HP website
( http://www.hp.com/products/servers/platforms )
«General diagnosis flowchart (on page 70 )»
Troubleshooting 77
Server fault indications flowchart
Symptoms:
•
Server boots, but a fault event is reported by Insight Management Agents
•
Server boots, but the internal health LED, external health LED, or component health LED is red or amber
NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation.
Troubleshooting 78
4
5
2
3
Possible causes:
•
Improperly seated or faulty internal or external component
•
Unsupported component installed
•
Redundancy failure
•
System overtemperature condition
Item See
1
6
7
8
•
«Integrated Management Log (on page 60 )» or in the HP ProLiant
Servers Troubleshooting Guide located on the Documentation CD or see «Troubleshooting resources»
•
«Event list error messages» in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see «Troubleshooting resources»
«Component identification (on page 7 )»
«Server health LEDs (on page 68 )»
System Management Homepage ( https://localhost:2381 )
«Power-on problems flowchart (» Server power-on problems flowchart » on page 72 )»
«HP Insight Diagnostics (on page 59 )» or in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
•
«Hardware problems» in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see «Troubleshooting resources»
•
Server maintenance and service guide, located on the Documentation
CD or the HP website
( http://www.hp.com/products/servers/platforms )
•
«Smart Array SCSI Diagnosis feature» or in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
«Troubleshooting resources»
•
Server maintenance and service guide, located on the Documentation
CD or the HP website
( http://www.hp.com/products/servers/platforms )
•
«HP contact information (on page 91 )»
Troubleshooting 79
POST error messages and beep codes
For a complete listing of error messages, refer to the «POST error messages» in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or on the HP website
( http://www.hp.com/support ).
Troubleshooting 80
WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before removing, replacing, reseating, or modifying system components.
Troubleshooting 81
Battery
If the server no longer automatically displays the correct date and time, you may need to replace the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.
WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk of personal injury:
•
Do not attempt to recharge the battery.
• Do not expose the battery to temperatures higher than 60°C (140°F).
•
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
•
Replace only with the spare designated for this product.
To remove the component:
1.
2.
3.
Power down the server (on page 17 ).
Extend or remove the server from the rack (» Remove the server from the rack » on page 17 ).
Remove the access panel (on page 18 ).
CAUTION: To prevent damage to the server or expansion boards, power down the server and remove all AC power cords before removing or installing the expansion boards.
4.
Remove the battery.
IMPORTANT: Replacing the system board battery resets the system ROM to its default configuration. After replacing the battery, reconfigure the system through BIOS Setup Utility.
To replace the component, reverse the removal procedure.
For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.
Battery 82
Regulatory compliance notices
Regulatory compliance identification numbers
For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product.
Federal Communications Commission notice
Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio
Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules. These rules place computers and related peripheral devices into two classes, A and
B, depending upon their intended installation. Class A devices are those that may reasonably be expected to be installed in a business or commercial environment. Class B devices are those that may reasonably be expected to be installed in a residential environment (for example, personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user.
FCC rating label
The FCC rating label on the device shows the classification (A or B) of the equipment. Class B devices have an FCC logo or ID on the label. Class A devices do not have an FCC logo or ID on the label. After you determine the class of the device, refer to the corresponding statement.
FCC Notice, Class A Equipment
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense.
Regulatory compliance notices 83
Declaration of conformity for products marked with the FCC logo, United States only
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
For questions regarding this product, contact us by mail or telephone:
•
Hewlett-Packard Company
P. O. Box 692000, Mail Stop 530113
Houston, Texas 77269-2000
•
1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement, calls may be recorded or monitored.)
For questions regarding this FCC declaration, contact us by mail or telephone:
•
Hewlett-Packard Company
P. O. Box 692000, Mail Stop 510101
Houston, Texas 77269-2000
•
1281-514-3333
To identify this product, refer to the part, series, or model number found on the product.
Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the equipment.
Cables
Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
Canadian notice (Avis Canadien)
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
European Union regulatory notice
Products bearing the CE marking comply with the following EU Directives:
•
Low Voltage Directive 2006/95/EC
•
EMC Directive 2004/108/EC
Regulatory compliance notices 84
•
Ecodesign Directive 2009/125/EC, where applicable
CE compliance of this product is valid if powered with the correct CE-marked AC adapter provided by HP.
Compliance with these directives implies conformity to applicable harmonized European standards
(European Norms) that are listed in the EU Declaration of Conformity issued by HP for this product or product family and available (in English only) either within the product documentation or at the following HP website
( http://www.hp.eu/certificates ) (type the product number in the search field).
The compliance is indicated by one of the following conformity markings placed on the product:
For non-telecommunications products and for EU harmonized telecommunications products, such as
Bluetooth® within power class below 10mW.
For EU non-harmonized telecommunications products (If applicable, a 4-digit notified body number is inserted between CE and !).
Please refer to the regulatory label provided on the product.
The point of contact for regulatory matters is Hewlett-Packard GmbH, Dept./MS: HQ-TRE, Herrenberger
Strasse 140, 71034 Boeblingen, GERMANY.
Disposal of waste equipment by users in private households in the European Union
This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
Japanese class A notice
Regulatory compliance notices 85
BSMI notice
Korean class A notice
Chinese notice
Class A equipment
Laser compliance
This product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiber optic transceiver. Each of these devices contains a laser that is classified as a Class 1 Laser Product in accordance with US FDA regulations and the IEC 60825-1. The product does not emit hazardous laser radiation.
Each laser product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser
Notice No. 50, dated June 24, 2007; and with IEC 60825-1:2007.
WARNING: Use of controls or adjustments or performance of procedures other than those specified herein or in the laser product’s installation guide may result in hazardous radiation exposure. To reduce the risk of exposure to hazardous radiation:
•
Do not try to open the module enclosure. There are no user-serviceable components inside.
•
Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein.
• Allow only HP Authorized Service technicians to repair the unit.
The Center for Devices and Radiological Health (CDRH) of the U.S. Food and Drug Administration implemented regulations for laser products on August 2, 1976. These regulations apply to laser products manufactured from August 1, 1976. Compliance is mandatory for products marketed in the United States.
Regulatory compliance notices 86
Battery replacement notice
WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk of personal injury:
• Do not attempt to recharge the battery.
•
Do not expose the battery to temperatures higher than 60°C (140°F).
•
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. To forward them to recycling or proper disposal, use the public collection system or return them to HP, an authorized HP Partner, or their agents.
For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.
Taiwan battery recycling notice
The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the
Waste Disposal Act to indicate the recovery marks on the batteries used in sales, giveaway or promotion.
Contact a qualified Taiwanese recycler for proper battery disposal.
Power cord statement for Japan
Regulatory compliance notices 87
Electrostatic discharge
Preventing electrostatic discharge
To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.
To prevent electrostatic damage:
•
Avoid hand contact by transporting and storing products in static-safe containers.
•
Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
•
Place parts on a grounded surface before removing them from their containers.
•
Avoid touching pins, leads, or circuitry.
•
Always be properly grounded when touching a static-sensitive component or assembly.
Grounding methods to prevent electrostatic discharge
Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts:
•
Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin.
•
Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats.
•
Use conductive field service tools.
•
Use a portable field service kit with a folding static-dissipating work mat.
If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part.
For more information on static electricity or assistance with product installation, contact an authorized reseller.
Electrostatic discharge 88
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
10°C to 35°C (50°F to 95°F)
Non-operating
-30°C to 60°C (-22°F to 140°F)
Relative humidity
(non-condensing)
Operating, maximum wet bulb temperature of 28°C (82.4°F)
10% to 90%
Non-operating, maximum wet bulb temperature of 38.7°C
(101.7°F)
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed.
Mechanical specifications
Specification Value
Dimensions
Height
Depth
Width
Weight (maximum)
Weight (one hard drive installed))
4.44 cm (1.75 in)
70 cm (27.56 in)
44.8 cm (17.64 in)
14.26 kg (31.4 lb)
10.37 kg (22.84 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HP ProLiant ATX 400 W power supply
Specification Value
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
Power supply output
100 to 240 VAC
47 Hz to 63 Hz
Limit at 6 A
570 W at 115 VAC
Specifications 89
Efficiency
Not less than 70% at 100%load
Not less than 70% at 50%load
Not less than 70% at 20%load
400 W
Rated output power
•
HP ProLiant Common slot 400 W power supply
Specification Value
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
Power supply output
100 to 127 VAC, 200 to
240 VAC
47 Hz to 63 Hz
6 A at 100 VAC
3 A at 200 VAC
570 W at 230 VAC
Efficiency
Rated output power
Not less than 85% at 100% load
Not less than 89% at 50% load
Not less than 85% at 20% load
400 W
Specifications 90
Support and other resources
Before you contact HP
Be sure to have the following information available before you call HP:
•
Active Health System log
Download and have available an Active Health System log for 3 days before the failure was detected.
For more information, see the HP iLO 4 User Guide or HP Intelligent Provisioning User Guide on the HP website ( http://www.hp.com/go/ilo/docs ).
•
Onboard Administrator SHOW ALL report (for HP BladeSystem products only)
For more information on obtaining the Onboard Administrator SHOW ALL report, see the HP website
( http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c
02843807 ).
•
Technical support registration number (if applicable)
•
Product serial number
•
Product model name and number
•
Product identification number
•
Applicable error messages
•
Add-on boards or hardware
•
Third-party hardware or software
•
Operating system type and revision level
HP contact information
For United States and worldwide contact information, see the Contact HP website
( http://www.hp.com/go/assistance ).
In the United States:
•
To contact HP by phone, call 1-800-334-5144. For continuous quality improvement, calls may be recorded or monitored.
•
If you have purchased a Care Pack (service upgrade), see the Support & Drivers website
( http://www8.hp.com/us/en/support-drivers.html
). If the problem cannot be resolved at the website, call 1-800-633-3600. For more information about Care Packs, see the HP website
( http://pro-aq-sama.houston.hp.com/services/cache/10950-0-0-225-121.html
).
Customer Self Repair
HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service
Support and other resources 91
providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship that part directly to you for replacement. There are two categories of CSR parts:
•
Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service.
•
Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.
NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty,
HP requires that an authorized service provider replace the part. These parts are identified as «No» in the
Illustrated Parts Catalog.
Based on availability and where geography permits, CSR parts will be shipped for next business day delivery. Same day or four-hour delivery may be offered at an additional charge where geography permits.
If assistance is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP. In cases where it is required to return the defective part to HP, you must ship the defective part back to HP within a defined period of time, normally five (5) business days. The defective part must be returned with the associated documentation in the provided shipping material. Failure to return the defective part may result in HP billing you for the replacement. With a customer self repair, HP will pay all shipping and part return costs and determine the courier/carrier to be used.
For more information about HP’s Customer Self Repair program, contact your local service provider. For the
North American program, refer to the HP website ( http://www.hp.com/go/selfrepair ).
Réparation par le client (CSR)
Les produits HP comportent de nombreuses pièces CSR (Customer Self Repair = réparation par le client) afin de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses. Si pendant la période de diagnostic, HP (ou ses partenaires ou mainteneurs agréés) détermine que la réparation peut être effectuée à l’aide d’une pièce CSR, HP vous l’envoie directement. Il existe deux catégories de pièces CSR:
Obligatoire — Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d’œuvre du service vous seront facturés.
Facultatif — Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également conçues pour permettre au client d’effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer ces pièces, l’intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit.
REMARQUE: Certaines pièces HP ne sont pas conçues pour permettre au client d’effectuer lui-même la réparation. Pour que la garantie puisse s’appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention «Non» dans le Catalogue illustré.
Les pièces CSR sont livrées le jour ouvré suivant, dans la limite des stocks disponibles et selon votre situation géographique. Si votre situation géographique le permet et que vous demandez une livraison le jour même ou dans les 4 heures, celle-ci vous sera facturée. Pour bénéficier d’une assistance téléphonique, appelez le
Centre d’assistance technique HP. Dans les documents envoyés avec la pièce de rechange CSR, HP précise s’il est nécessaire de lui retourner la pièce défectueuse. Si c’est le cas, vous devez le faire dans le délai indiqué, généralement cinq (5) jours ouvrés. La pièce et sa documentation doivent être retournées dans l’emballage fourni. Si vous ne retournez pas la pièce défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d’une pièce CSR, HP supporte l’ensemble des frais d’expédition et de retour, et détermine la société de courses ou le transporteur à utiliser.
Support and other resources 92
Pour plus d’informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d’informations sur ce programme en Amérique du Nord, consultez le site Web HP
( http://www.hp.com/go/selfrepair ).
Riparazione da parte del cliente
Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente (CSR, Customer Self Repair). Se in fase di diagnostica HP (o un centro di servizi o di assistenza
HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirà direttamente al cliente per la sostituzione. Vi sono due categorie di parti CSR:
Obbligatorie – Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.
Opzionali – Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto.
NOTA: alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate da un «No» nel Catalogo illustrato dei componenti.
In base alla disponibilità e alla località geografica, le parti CSR vengono spedite con consegna entro il giorno lavorativo seguente. La consegna nel giorno stesso o entro quattro ore è offerta con un supplemento di costo solo in alcune zone. In caso di necessità si può richiedere l’assistenza telefonica di un addetto del centro di supporto tecnico HP. Nel materiale fornito con una parte di ricambio CSR, HP specifica se il cliente deve restituire dei componenti. Qualora sia richiesta la resa ad HP del componente difettoso, lo si deve spedire ad HP entro un determinato periodo di tempo, generalmente cinque (5) giorni lavorativi. Il componente difettoso deve essere restituito con la documentazione associata nell’imballo di spedizione fornito. La mancata restituzione del componente può comportare la fatturazione del ricambio da parte di HP.
Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di spedizione e resa e sceglie il corriere/vettore da utilizzare.
Per ulteriori informazioni sul programma CSR di HP contattare il centro di assistenza di zona. Per il programma in Nord America fare riferimento al sito Web HP ( http://www.hp.com/go/selfrepair ).
Customer Self Repair
HP Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und höhere
Flexibilität beim Austausch defekter Bauteile zu ermöglichen. Wenn HP (oder ein HP Servicepartner) bei der
Diagnose feststellt, dass das Produkt mithilfe eines CSR-Teils repariert werden kann, sendet Ihnen HP dieses
Bauteil zum Austausch direkt zu. CSR-Teile werden in zwei Kategorien unterteilt:
Zwingend – Teile, für die das Customer Self Repair-Verfahren zwingend vorgegeben ist. Wenn Sie den
Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen
Service berechnet.
Optional – Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer
Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche
Kosten anfallen.
Support and other resources 93
HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des
Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.
CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert.
Für bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen
Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-Ersatzteil geliefert werden, können Sie entnehmen, ob das defekte Teil an HP zurückgeschickt werden muss. Wenn es erforderlich ist, das defekte Teil an HP zurückzuschicken, müssen Sie dies innerhalb eines vorgegebenen
Zeitraums tun, in der Regel innerhalb von fünf (5) Geschäftstagen. Das defekte Teil muss mit der zugehörigen
Dokumentation in der Verpackung zurückgeschickt werden, die im Lieferumfang enthalten ist. Wenn Sie das defekte Teil nicht zurückschicken, kann HP Ihnen das Ersatzteil in Rechnung stellen. Im Falle von Customer
Self Repair kommt HP für alle Kosten für die Lieferung und Rücksendung auf und bestimmt den
Kurier-/Frachtdienst.
Weitere Informationen über das HP Customer Self Repair Programm erhalten Sie von Ihrem Servicepartner vor Ort. Informationen über das CSR-Programm in Nordamerika finden Sie auf der HP Website unter
( http://www.hp.com/go/selfrepair ).
Reparaciones del propio cliente
Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer Self
Repair, CSR) para minimizar el tiempo de reparación y ofrecer una mayor flexibilidad a la hora de realizar sustituciones de componentes defectuosos. Si, durante la fase de diagnóstico, HP (o los proveedores o socios de servicio de HP) identifica que una reparación puede llevarse a cabo mediante el uso de un componente
CSR, HP le enviará dicho componente directamente para que realice su sustitución. Los componentes CSR se clasifican en dos categorías:
•
Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a
HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.
•
Opcional: componentes para los que la reparación por parte del usuario es opcional. Estos componentes también están diseñados para que puedan ser reparados por el usuario. Sin embargo, si precisa que HP realice su sustitución, puede o no conllevar costes adicionales, dependiendo del tipo de servicio de garantía correspondiente al producto.
NOTA: Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la palabra «No» en el catálogo ilustrado de componentes.
Según la disponibilidad y la situación geográfica, los componentes CSR se enviarán para que lleguen a su destino al siguiente día laborable. Si la situación geográfica lo permite, se puede solicitar la entrega en el mismo día o en cuatro horas con un coste adicional. Si precisa asistencia técnica, puede llamar al Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico. Con el envío de materiales para la sustitución de componentes CSR, HP especificará si los componentes defectuosos deberán devolverse a HP. En aquellos casos en los que sea necesario devolver algún componente a HP, deberá hacerlo en el periodo de tiempo especificado, normalmente cinco días laborables. Los componentes defectuosos deberán devolverse con toda la documentación relacionada y con el embalaje de envío. Si no enviara el componente defectuoso requerido, HP podrá cobrarle por el de sustitución. En el caso de todas
Support and other resources 94
sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio.
Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su proveedor de servicios local. Si está interesado en el programa para Norteamérica, visite la página web de HP siguiente ( http://www.hp.com/go/selfrepair ).
Customer Self Repair
Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot een minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt HP dat onderdeel rechtstreeks naar u, zodat u het defecte onderdeel daarmee kunt vervangen. Er zijn twee categorieën CSR-onderdelen:
Verplicht: Onderdelen waarvoor reparatie door de klant verplicht is. Als u HP verzoekt deze onderdelen voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in rekening gebracht.
Optioneel: Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het product.
OPMERKING: Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen.
Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met «Nee».
Afhankelijk van de leverbaarheid en de locatie worden CSR-onderdelen verzonden voor levering op de eerstvolgende werkdag. Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden aangeboden, indien dit mogelijk is gezien de locatie. Indien assistentie gewenst is, belt u een HP Service
Partner om via de telefoon technische ondersteuning te ontvangen. HP vermeldt in de documentatie bij het vervangende CSR-onderdeel of het defecte onderdeel aan HP moet worden geretourneerd. Als het defecte onderdeel aan HP moet worden teruggezonden, moet u het defecte onderdeel binnen een bepaalde periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het defecte onderdeel moet met de bijbehorende documentatie worden geretourneerd in het meegeleverde verpakkingsmateriaal. Als u het defecte onderdeel niet terugzendt, kan HP u voor het vervangende onderdeel kosten in rekening brengen. Bij reparatie door de klant betaalt HP alle verzendkosten voor het vervangende en geretourneerde onderdeel en kiest HP zelf welke koerier/transportonderneming hiervoor wordt gebruikt.
Neem contact op met een Service Partner voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website ( http://www.hp.com/go/selfrepair ).
Reparo feito pelo cliente
Os produtos da HP são projetados com muitas peças para reparo feito pelo cliente (CSR) de modo a minimizar o tempo de reparo e permitir maior flexibilidade na substituição de peças com defeito. Se, durante o período de diagnóstico, a HP (ou fornecedores/parceiros de serviço da HP) concluir que o reparo pode ser efetuado pelo uso de uma peça CSR, a peça de reposição será enviada diretamente ao cliente.
Existem duas categorias de peças CSR:
Obrigatória – Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
Support and other resources 95
Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.
OBSERVAÇÃO: Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão identificadas com a marca «No» (Não), no catálogo de peças ilustrado.
Conforme a disponibilidade e o local geográfico, as peças CSR serão enviadas no primeiro dia útil após o pedido. Onde as condições geográficas permitirem, a entrega no mesmo dia ou em quatro horas pode ser feita mediante uma taxa adicional. Se precisar de auxílio, entre em contato com o Centro de suporte técnico da HP para que um técnico o ajude por telefone. A HP especifica nos materiais fornecidos com a peça CSR de reposição se a peça com defeito deve ser devolvida à HP. Nos casos em que isso for necessário, é preciso enviar a peça com defeito à HP dentro do período determinado, normalmente cinco (5) dias úteis.
A peça com defeito deve ser enviada com a documentação correspondente no material de transporte fornecido. Caso não o faça, a HP poderá cobrar a reposição. Para as peças de reparo feito pelo cliente, a
HP paga todas as despesas de transporte e de devolução da peça e determina a transportadora/serviço postal a ser utilizado.
Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP
( http://www.hp.com/go/selfrepair ).
Support and other resources 96
Support and other resources 97
Support and other resources 98
Acronyms and abbreviations
ABEND abnormal end
ACU
Array Configuration Utility
ASR
Automatic Server Recovery
BBWC battery-backed write cache
CSA
Canadian Standards Association
CSR
Customer Self Repair
DDR double data rate
IEC
International Electrotechnical Commission iLO
Integrated Lights-Out
IML
Integrated Management Log
NMI nonmaskable interrupt
NVRAM nonvolatile memory
Acronyms and abbreviations 99
ORCA
Option ROM Configuration for Arrays
PCIe
Peripheral Component Interconnect Express
POST
Power-On Self Test
PSP
HP ProLiant Support Pack
RBSU
ROM-Based Setup Utility
RDIMM registered dual in-line memory module
RDP
Rapid Deployment Pack
SAS serial attached SCSI
SATA serial ATA
SFF small form factor
SIM
Systems Insight Manager
TMRA recommended ambient operating temperature
TPM
Trusted Platform Module
UDIMM unregistered dual in-line memory module
Acronyms and abbreviations 100
UID unit identification
USB universal serial bus
VCA
Version Control Agent
Acronyms and abbreviations 101
Documentation feedback
HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback ( mailto:[email protected]
).
Include the document title and part number, version number, or the URL when submitting your feedback.
Documentation feedback 102
Index
A
access panel 18
air baffle 19, 20
Array Configuration Utility (ACU) 55
ASR (Automatic Server Recovery) 57
authorized reseller 89
auto-configuration process 54
Automatic Server Recovery (ASR) 57
B
battery 80, 85
battery-backed write cache battery pack 37
Battery-backed write cache LEDs 14
BIOS Serial Console 55
BIOS upgrade 57
boot options 55
BSMI notice 84
buttons 7
C
cable management arm 25
cables 47, 67, 82
cabling 47, 48, 50
cabling, BBWC 49
cabling, optical drive 50
Canadian notice 82
Care Pack 22, 62
cautions 64
Change Control 62
Chinese notice 84
components 7 components, identification 7
components, system board 11, 12
configuration of system 26, 53
connection problems 67
connectors 7
contacting HP 89
CSR (customer self repair) 89 customer self repair (CSR) 89
D
diagnostic tools 53, 57, 58 diagnostics utility 58
DIMM identification 28
DIMM population guidelines 29
DIMM slot locations 12
DIMMs 12, 27
DIMMs, single- and dual-rank 27
drive blank 30 drive information 30
drivers 60
drives 30
drives, removing 31
E
electrical grounding requirements 24
electrostatic discharge 86
enabling the Trusted Platform Module 45
environmental requirements 22, 87 environmental specifications 87
Erase Utility 58
error messages 79
European Union notice 82
expansion board options 35
F
fans 15
FCC rating label 81
features 7
Federal Communications Commission (FCC)
notice 81, 82
firmware 61
front panel components 7
front panel LEDs 8
G
general diagnosis flowchart 69
grounding methods 86
grounding requirements 24
Index 103
H
hardware options installation 25, 27
health driver 57
health LEDs 67
help resources 89
hot-plug drive, installing 32
HP Insight Diagnostics 58, 59
HP Insight Remote Support software 59
HP Smart Update Manager overview 61
HP technical support 89
I
identification number 81
iLO (Integrated Lights-Out) 57 iLO 3 (Integrated Lights-Out 3) 57
iLO ports 34
IML (Integrated Management Log) 59
Important Safety Information document 63
Insight Diagnostics 58, 59, 60
installation services 22
installation, server options 25, 27 installing hardware 27
installing PCI riser cage 19
installing the access panel 18
installing the server into the rack 25
installing the Trusted Platform Module board 44
Integrated Lights-Out (iLO) 57
Integrated Lights-Out 3 (iLO 3) 57
Integrated Management Log (IML) 59
J
Japanese notice 83
K
Korean notices 84
L
laser devices 84
LEDs, troubleshooting 63
loose connections 67
M
management tools 57
mechanical specifications 87
memory 28, 29 memory configurations 28, 29
memory options 27 memory subsystem architecture 27
memory, mirrored 55 mirrored memory 55
N
NMI functionality 12
nonredundant power supply cabling 47
O
operating system crash 57
operating systems 26, 61
optical drive 32
optical drive cable 50
optimum environment 22
Option ROM Configuration for Arrays (ORCA) 56
options installation 22, 25, 27
ORCA (Option ROM Configuration for Arrays) 56
OS boot problems flowchart 76
P
PCI expansion slots 10
phone numbers 89
POST error messages 79
POST problems flowchart 74
power cord 64, 85
power distribution unit (PDU) 24
Power On button 26
power requirements 24
power supply specifications 87
powering down 17
powering up 17, 26
powering up the server 17
pre-diagnostic steps 63
preparation procedures 17, 65
problem diagnosis 63
processors 66
ProLiant Support Pack (PSP) 61
PSPs, overview 61
R
rack installation 22, 24
rack mounting hardware 25
rack resources 22
rack stability 64 rack warnings 24, 64
rack, removing server from 17
RBSU (ROM-Based Setup Utility) 53, 54
rear panel components 8
Index 104
rear panel LEDs 9
redundant power supply 39
registering the server 26
regulatory compliance notices 81
removing PCIe riser cage 18
removing server from rack 17
removing the access panel 18
required information 89
retaining the recovery key/password 45
ROMPaq utility 57
RPS cabling 48
S
safety considerations 24, 63, 86
SAS and SATA device numbers 13
SAS drive LEDs 13
SAS hard drive cabling 51
SATA drive LEDs 13
scripted installation 53
serial number 56
series number 81
server cabling 47
server fault indications flowchart 77
server features and options 27
server power-on problems flowchart 71
server setup 22, 60
service notifications 67
shipping carton contents 25
SmartStart autorun menu 53
SmartStart Scripting Toolkit 53
SmartStart, overview 53
space and airflow requirements 23
specifications 87 specifications, environmental 87 specifications, server 87
start diagnosis flowchart 68
static electricity 86
storage controller 36
support 59, 89 support and other resources 89
supported operating systems 61
symbols on equipment 63
symptom information 65
system board components 10
system board LEDs 11
system components 7
system maintenance switch 11
T
Taiwan battery recycling notice 85
telephone numbers 89
temperature requirements 23, 87
Torx screwdriver 16
TPM (Trusted Platform Module) 43, 45
troubleshooting 63, 66
troubleshooting flowcharts 68
U
UDIMM configuration 28
USB support 58
utilities 53 utilities, deployment 53
V
ventilation 22
Version Control 60
W
warnings 24, 64
website, HP 89
Index 105
Перед вами файл pdf, где представлена инструкция (руководство) на русском для HP Proliant BL460c Gen9/1xXeon8C E5-2640v3 2.6GHz(20MB)/2x16GbR2D_2133/P244br (727028-B21). Вы можете скачать ее либо изучить в онлайн режиме.
Подробные сведения об инструкции:
Скачать инструкцию к HARPER HDT2-1110
ЗАГРУЗИТЬ
Просмотр инструкции онлайн