E21 Installation Manual

(Version: V1.09)

loading

Related Manuals for Estun E21

Summary of Contents for Estun E21

  • Page 1
    E21 Installation Manual (Version: V1.09)
  • Page 2: Table Of Contents

    E21 Installation Manual Contents Preface ………………….1 Chapter 1 Specification ………………… 3 1.1 Display ………………….3 1.2 Internal memory ………………..3 1.3 Electrical specification ………………3 Chapter 2 Installation ………………..5 2.1 Announcements before installation …………..5 2.2 Installation space and direction …………… 5 2.3 Installation environment ………………

  • Page 3
    7.2.2 Equipment grounding design …………….33 7.3 Protective measures ………………34 7.3.1 Measures to ensure electromagnetic compatibility ……….34 7.3.2 Instructions to E21 electromagnetic capability installation ……..36 7.3.3 Install freewheeling diode on relay …………..36 7.4 Demonstration of AC Asynchronies motor wiring ………. 37…
  • Page 4: Preface

    E21 Installation Manual Preface Target reader This manual guides the following operators to install, configure and maintain the E21 press break numerical control device:  Machine tool operators  Installation and maintenance personnel Range of application Installation and maintenance personnel can install and operate this device properly by referring to this manual.

  • Page 5
    E21 Installation Manual Low temperature; refer to JB-T 8832-2001 General requirements for numerical control device of machine tools, 0 ℃, 2hours. Low temperature store -20℃. Criteria: normal start up, normal operation. High temperature, refer to JB-T 8832-2001 General requirements for numerical control device of machine tools, 40 ℃, 2hours.
  • Page 6: Chapter 1 Specification

    E21 Installation Manual Chapter 1 Specification 1.1 Display LCD display Dimension of display window: 54.38mm*54.38mm Dot matrix: 160*160 Status light Green indicates running Red indicates stop 1.2 Internal memory Capable of storing 40 programs, each program includes 25 steps at most.

  • Page 7
    E21 Installation Manual Storage temperature: -20~55℃ Encoder specification Power supply: DC 12V Incremental encoder: single-ended output, with Z/C phase Output: voltage-type…
  • Page 8: Chapter 2 Installation

    Therefore, before turning on the power supply, check the connection of input output grounding and power supply wire.  Grounding terminal of E21 digital control device must be grounded in correct way, with low impedance lower than 0.3Ω.  Do not dismantle the device without authorization so as to avoid malfunction.

  • Page 9: Installation Dimension

    E21 Installation Manual 2.4 Installation dimension The installation method is panel mounting. Installation dimension and drawings are shown in Figure 2-1. Unit: mm 4-M4 pressure riveting screws High 8 mm Figure 2-1 Panel Installation Dimension…

  • Page 10: Installation Layout

    E21 Installation Manual 2.5 Installation layout 2.5.1 Layout of rear panel Rear panel block diagram is as shown in Figure 2-2, consisting of power port (POWER), input port (INPUT), output port (OUTPUT), encoder port (X, Y), and communication port (COMM).

  • Page 11
    E21 Installation Manual Socket number External port name External port description 7 pin. 24VDC, maximum load 10mA, INPUT opto-coupler isolation, maximum withstanding voltage 40V. Incremental encoder is 12V single-ended output, with pulse frequency up to 100KHz. Meanwhile, the port supplies power externally X-ENCODER (as input power of encoder).
  • Page 12: Overall Wiring Scheme

    E21 Installation Manual 2.5.3 Overall wiring scheme Overall wiring scheme is as shown in Figure 2-3. Figure 2-3 Overall wiring schemes…

  • Page 13: Electrical Wiring Scheme

    E21 Installation Manual 2.5.4 Electrical wiring scheme Electrical wiring scheme is as shown in Figure 2-4. 12V single-point 12V single-point incremental encoder incremental encoder Shell Encoder cable Encoder cable grounding shield layer shield layer Y-ENCODER X-ENCODER Shell grounding terminal … ……

  • Page 14: Definition Of Device Interface

    E21 Installation Manual 2.6 Definition of device interface 2.6.1 Definition of power interface Definition of terminal is as shown in Table 2-2. Table 2-2 Description of power terminal Terminal No. Signal Description Input terminal of device power, connect to DC +24V.

  • Page 15: Definition Of External Output Interface

    E21 Installation Manual Terminal No. Signal Description Y-axis reference point signal, DC +24V signal input, connect Y-EOT to low limit signal of Y-axis block generally. Block touches reference point switch, +24V signal is connected. Count Retain Retain The pump signal must be connected to DC 24V when the MRDY machine is normally running.

  • Page 16: Definition Of Encoder Interface

    E21 Installation Manual Terminal No. Signal Description COM2 Common port of system output signal must connect to 0V of I/O power supply. 2.6.4 Definition of encoder interface Encoder interface is DB-9 plug (female), definition of terminal is as shown in Table 2-5.

  • Page 17: Chapter 3 Parameter Description Of Machine Tool

    E21 Installation Manual Chapter 3 Parameter Description of Machine Tool 3.1 Enter parameter page Steps to entering parameter page are as below. Step 1 Power on, and press two times to enter Programming Constant page, as shown in Figure 3-1. On this page, program constant can be set.

  • Page 18: Parameter Description

    E21 Installation Manual <Note>: You can directly enter Teach Page by input password “1212” and press on Program Constant page. Step 4 Input password 36987 on the CONST page to enter Motor-Speed Detection page, as shown in Figure 3-4. 1.X Motor Dec.

  • Page 19
    E21 Installation Manual Name Default value Range Description  mm/inch 0 or 1 0: Metric  1: inch  中文/English 0 or 1 0: Chinese  1: English Release Time 0~99.99s Interval between valid yield signal and unloading output when system starts.
  • Page 20
    E21 Installation Manual Name Default value Range Description  X-Enable 0 or 1 0:disable  1:enable  Encoder Dir. 0 or 1 0:decreasing  1:increasing  Teach. En. 0 or 1 0:disable, enable the orientation function.  1:enable, enable the teaching function.
  • Page 21
    E21 Installation Manual Name Default value Range Description  Repeat Enable 1~99999999 0:disable  1:enable Repeat Time 0~99.99s Interval of back gauge reposition when repeat position Mute Dis. 0~9999.999mm Conversion distance between high speed and low speed. Motor lowers speed when enter this range.
  • Page 22
    In general, the fixed frequency is 50Hz. [Note] The parameter description of X-axis and Y-axis are the same. If the Vacon transducer is used, the parameter setting for communicating E21 device is as below: E21 Communication Parameter Setting of Vacon P2.1 →…
  • Page 23
    E21 Installation Manual The parameter description of Motor-Speed Detection is as shown in Table 3-1. Table 3-1 Parameter description of Motor-Speed Detection Name Default Range Description Whether to enable the Motor-Speed Detection function. X-Motor Det. 0 or 1  0: Disabled …
  • Page 24
    E21 Installation Manual Name Default Range Description X-axis motor begins accelerate from High-speed to the detection end. It will not detect X-axis T3 0~9.99s the motor speed in this setting value. This parameter applies to only the inverter. [Note] The parameter description of X-axis and Y-axis are the same.
  • Page 25: Chapter 4 Diagnosis

    E21 Installation Manual Chapter 4 Diagnosis When diagnosis is in progress, do not start oil pump. 4.1 Enter diagnosis page This system provides diagnosis tests for input, output, keyboard, FRAM, encoder and LCD, etc. Steps to enter diagnosis page are as follows: Step 1 Power on, the device displays the single-step programming page, Stop Indicator lights.

  • Page 26: Output Diagnosis

    E21 Installation Manual 4.3 Output diagnosis When you enter the DIAGNOSE page, select 2. OUT DIAG. to enter OUT DIAG. page, as shown in Figure 4-3. [Operation Guide] Using the Arrow Key to move the cursor to the corresponding port…

  • Page 27: Fram Diagnosis

    E21 Installation Manual 4.5 FRAM diagnosis When you enter the DIAGNOSE page, select 4. FRAM DIAG. to enter FARM DIAG. page, as shown in Figure 4-5. , the page displays “Diagnosing”. When the diagnosis is [Operation Guide] Press success, the page will display “The result is: OK”. However, if the page long displays “Diagnosing”, it indicates the memory is failure.

  • Page 28: Lcd Diagnosis

    E21 Installation Manual 4.7 LCD diagnosis When you enter the DIAGNOSE page, select 6. LED DIAG. to enter LED DIAG. page, as shown in Figure 4-7. [Operation Guide] Press , the device will star to diagnose the LCD. To stop the diagnosis, press LCD DIAG.

  • Page 29: Chapter 5 Commissioning

    If necessary, cut down motor power immediately to avoid accident. 5.1 Preparation before Commissioning  Check E21 power line, ground wire, input/output signal wire and encoder plug for reliable and accurate connection.  Check whether output voltage of 24V switch power is normal or not.

  • Page 30: Action Commissioning

    E21 Installation Manual  Over.Dis.: 5.00  Repeat Enable: 1  Repeat Time: 1.00  Stop Dis.: 100  Mute Dis.: 4000  Overrun En.: 0 (Bilateral orientation is enabled) Y-Axis parameter setting Y-axis parameter setting: the method is similar to the setting of X axis parameter 5.2.2 Action commissioning…

  • Page 31: Counting Commissioning

    E21 Installation Manual 5.2.4 Counting commissioning Edit multistep program on programming page (setting number of work piece is over 1, single step is excluded), press “Start”, depress pedal to dry running when X, Y axis are in position (note Y axis position and pressure), observe whether counting has increased;…

  • Page 32: Chapter 6 Maintenance

    E21 Installation Manual Chapter 6 Maintenance 6.1 Instructions to maintenance In order to use this system safely and properly, follow the instructions.  When power is on or system operates normally, do not open cover plate or panel as it may damage the components.

  • Page 33: Periodic Inspection

    E21 Installation Manual Inspection item Standard content Standard Treatment specification Connection status Check terminal Screw is not loose Fastening screw for loosening terminal screw. LED display status Check whether LED LED (green) indicate display is correct. system running, LED (red) indicate system stop.

  • Page 34
    E21 Installation Manual Inspection item Standard Standard Treatment content specification Install Tension, Mobile module Module must Secure the mobility be installed screw. If securely. CPU and I/O module loses, fasten them by screws. Dust and Visual No dust or Remove and…
  • Page 35: Chapter 7 Appendix

    7.2.1 Ground classification in equipment cabinet Ground in equipment cabinet is divided into three categories:  Signal ground: for example, signal reference in E21 controller;  Shield ground: the shield layer of communication cable can prevent the system from external interference and hinder internal noise interfere other equipment. The ground shield layer connected to be called shield ground must connect to protective ground.

  • Page 36: Equipment Grounding Design

    RC net. RC network of E21 is integrated inside the product with one end connect to signal ground, and the other end connect to ground (three pins of POWER terminal), as shown in Figure 7-1.

  • Page 37: Protective Measures

    7.3 Protective measures 7.3.1 Measures to ensure electromagnetic compatibility E21 and its components are specially designed for industrial environment with strong electromagnetic compatibility. But when install and operate, take possible interference by the outside into account, and improve reliability and stability of the system.

  • Page 38
    E21 Installation Manual Coupling mode Cause Typical cases Inductive Changing current flows Transformer; coupling through current loop. Contactor and relay pull-in or disconnect; High frequency signal cable, etc. Radio frequency Space electromagnetic field coupling makes guide line generate induced voltage current.
  • Page 39: Instructions To E21 Electromagnetic Capability Installation

    E21 Installation Manual 7.3.2 Instructions to E21 electromagnetic capability installation  E21 may be installed outside the cabinet. If work environment is poor, keep E21 close to cabinet as much as possible;  Metal housing shall connect to protective ground via earth conductor, and ground resistance shall be no higher than 0.3 ohm;…

  • Page 40: Demonstration Of Ac Asynchronies Motor Wiring

    E21 Installation Manual 7.4 Demonstration of AC Asynchronies motor wiring Demonstration of AC asynchronism motor wiring is as shown in the following figure. Power COMMUNICATION ENCODER 1, 6 2, 7 RS485A RS485B Others 8, 9 Shell EARTH Shell EARTH…

  • Page 41
    E21 Installation Manual…

Главное содержание

Контроллеры станков с ЧПУ

  • Контроллер ESTUN E21 v. 1.06 (русский) — Руководство по эксплуатации (инструкция) контроллера для гидравлических листогибов.

Руководство (инструкция) Estun E21

  • Контроллер ESTUN E21S v. 1.06 (русский) — Руководство по эксплуатации (инструкция) контроллера для гидравлических листорезных станков.

Estun E21S на русском

  • Контроллер ESTUN E210 v. 1.02 (русский) — Руководство по эксплуатации (инструкция) контроллера для гидравлических листогибов.

Руководство (инструкция) Estun E210

  • Контроллер DELEM DA-52s V0812 для ПО Вер.3.2 (русский) — Руководство по эксплуатации (инструкция) контроллера для гидравлических листогибов.

Руководство (инструкция) Delem DA-52s

  • JQ LASER BCS100 (русский) V.2.25 — Руководство пользователя контроллера высоты для станков лазерной резки металла с ЧПУ

Руководство (инструкция) BCS100

  • Контроллер PA 8000 Ред.04.09 Вер.ПО 3.Х  (русский) — Руководство по эксплуатации (инструкция) контроллера.

Руководство (инструкция) Power AutomationPA8000

Контроллер распределенного мониторинга температуры OTS3/LHD3

  • Контроллеры серии OTS3/LHD3 — инструкции по безопасности

  • Контроллеры серии OTS3/LHD3 — руководство по установке

  • Контроллеры серии OTS3/LHD3 — руководство по эксплуатации

Предыдущая работа

Просмотров: 1173
Дата добавления: 13.02.17 в 15:19
Дата обновления: 19.02.20 в 14:05

Перевод руководства по эксплуатации контроллера листогиба Estun E21.

Следующая работа

f_49358a1a44bcc71d.pdf

pdf, 274.80 Кб  

f_47958a1a44bdd0e8.pdf

pdf, 262.64 Кб  


Продолжая пользоваться сайтом, вы соглашаетесь с

условиями использования файлов cookie


Low temperature; refer to JB-T 8832-2001 General requirements for

numerical control device of machine tools, 0 ℃, 2hours. Low temperature

store -20℃. Criteria: normal start up, normal operation.

High temperature, refer to JB-T 8832-2001 General requirements for

numerical control device of machine tools, 40 ℃, 2hours. High temperature

store 55℃. Criteria: normal operation.

Constant temperature wet, refer to JB-T 8832-2001 General requirements for

numerical control device of machine tools, 40 ℃, humidity 93%~95%, 2 hours.

Criteria: normal operation.

Vibration impact, refer to JB-T 8832-2001 General Requirements for numerical

control device of machine tools.

Personnel

Only authorized and properly trained person is allowed to operate this equipment.

Any person without necessary training is not allowed to use this control system, not

even for temporary use.

Area of responsibility distributed for personnel participating in installing, operating

and servicing equipment shall be stipulated explicitly and be confirmed eligible.

E21 Installation Manual

2

при подходе к нижней точке паунсон останавливается в ней и начинает давить. при этом не отключается. давление нарастает. в итоге срабатывает либо предохранительный клапан, либо просто на стоп выключаем. при этом таймер стоит на 1 сек. (т.е фактически это означает, что при вхождении в режим медленного опускания он должен двигаться 1 секунду ? )

Так и должно быть. Когда включается нижний концевик, начинается рабочий ход (прессование). Но манометр не показывает давление, т.к. есть движение балки. Как балка остановилась в НМТ, манометр начнет показывать давление. Причем Вы можете давить хоть 10 сек, и ничего не должно происходить. Показание на манометре — это как раз настройка предохранительного клапана.

Хорошо бы посмотреть вашу электросхему, я бы на пальцах объяснил назначение каждого таймера

См. гидравлическую схему, хотя у Вас она может быть немного другая.

post-10447-071662100_1521588070_thumb.jpg

Предохранительный клапан 10 устанавливает давление в системе.

Предохранительный клапан 60 поддерживает балку в верхнем положение.

Предохранительный клапан 90 — для аварийного сброса давления в линии слива.

и можно ли заставить движки двигаться медленнее?

Опять надо смотреть электросхему. Если движки запитаны через частотник, то да. Если напрямую, их обороты мы не уменьшим.

сейчас при задании по Х например 100, он движется к этой цели, пролетает 5мм, потом возвращается, и так пока не попадет в допуск 0,2мм.

У Вас скорее всего установлено однонаправленное позиционирование.

Overrun En = 1

Over.Dis = 5 мм

можно ли сделать так, чтобы он медленно подходил к этой точке?

в настройка есть пункт Safe-X — по умолчанию 10

но никакого медленного режима не включается

У Вас скорее всего односкоростной привод (без частотника). Поэтому нельзя сделать медленную скорость.

Понравилась статья? Поделить с друзьями:
  • Амоксиклав 875 125 инструкция по применению цена срок годности
  • Руководство 25 11а по сертификации систем электронной индикации самолетов транспортной категории
  • Должностная инструкция художественного руководителя дома культуры образец
  • Швейная машинка cobra jet lady инструкция на русском языке
  • Пульт для телевизора power инструкция на русском языке