USER’S MANUAL

PMS-970

Programmable Meter

Firmware: from v.5.00

APLISENS S.A., 03-192 Warsaw, ul. Morelowa 7

tel. +48 22 814 07 77; fax +48 22 814 07 78

www.aplisens.pl, e-mail:

aplisens@aplisens.pl

loading

Related Manuals for Aplisens PMS-970

Summary of Contents for Aplisens PMS-970

  • Page 1
    EN.IO.PMS-970 Revision 01.A.002 OCTOBER 2019 USER’S MANUAL PMS-970 Programmable Meter Firmware: from v.5.00 APLISENS S.A., 03-192 Warsaw, ul. Morelowa 7 tel. +48 22 814 07 77; fax +48 22 814 07 78 www.aplisens.pl, e-mail: aplisens@aplisens.pl…
  • Page 2
    Installation of intrinsically safe devices must be conducted very carefully, following all standards and laws applicable for installations of this kind. Changes made to the production may be introduced before the paper version of the user’s manual is updated. The up-to-date user’s manual is available on the manufacturer’s website: www.aplisens.pl.
  • Page 3: Table Of Contents

    EN.IO.PMS-970 TABLE OF CONTENTS INTRODUCTION ………………….2 SAFETY ……………………2 SET LIST …………..Błąd! Nie zdefiniowano zakładki. TRANSPORT AND STORAGE………………3 4.1. Transport ……………………3 4.2. Storage ……………………3 WARRANTY ……………………. 3 STRUCTURE …………… Błąd! Nie zdefiniowano zakładki. INSTALLATION ………………….4 CONNECTING ………………….

  • Page 4: Introduction

    EN.IO.PMS-970 INTRODUCTION The subject of this instruction manual is the PMS-970 programmable meter. The manual includes data, hints, and recommended action for installation and usage of the meter, as well as troubleshooting tips. SAFETY  Read this instruction carefully prior to, installation, startup, or any other work.

  • Page 5: Transport And Storage

    CONSTRUCTION The PMS-970 meter has two measuring inputs – one 0-20mA current input and one 0-10V voltage input. The current input is equipped with a safety device that protects the measuring resistor from damage. The input current is limited to 40 mA (typically). When the temperature of the measuring resistor falls, the safety device will automatically switch off and the system displays the measurement value again.

  • Page 6: Installation

    EN.IO.PMS-970 INSTALLATION The device is designed and made in a way that provides maximum safety of use and resistance to interference that occur in a typical industrial environment. For these features to be fully used, the installation of the device should be conducted properly, according to the relevant standards.

  • Page 7
    EN.IO.PMS-970 Pic. 7.2 Acceptable installation dimensions Pic. 7.3 Fixing with holders Pic. 7.4 Installation of several devices Revision 01.A.002/2019.10…
  • Page 8: Connecting

    EN.IO.PMS-970 CONNECTING Clamp no. 3 is the functional grounding clamp. Grounding the clamp is necessary for protection against interference. The clamp is also used for connecting the shields of measuring wires. All connection and installation steps must be performed with power disconnected.

  • Page 9
    EN.IO.PMS-970 Due to possible significant interference occurring in industrial systems, use adequate precautions that ensure proper operation of the device. Disregarding the following tips may, in certain circumstances, lead to exceeding the levels of electromagnetic disturbance for a typical industrial environment, which in turn may cause incorrect readout on the device.
  • Page 10
    EN.IO.PMS-970 Pic. 8.2 Description of terminals for standard version (see nameplate) Pic. 8.3 Description of terminals for standard version Revision 01.A.002/2019.10…
  • Page 11
    EN.IO.PMS-970 Pic. 8.4 Description of terminals for version with additional passive current output (see nameplate) Pic. 8.5 Description of terminals for version with additional passive current output Pic. 8.6 Connection of 2-lead current transmitters Revision 01.A.002/2019.10…
  • Page 12
    EN.IO.PMS-970 Pic. 8.7 Connection of 2-lead current transmitters Pic. 8.8 Connection of 3-lead current transmitters Pic. 8.9 Connection of 3-lead current transmitters Revision 01.A.002/2019.10…
  • Page 13
    EN.IO.PMS-970 Pic. 8.10 Connection of voltage transmitters Pic. 8.11 Connection of voltage transmitters Pic. 8.12 Connection of passive current output Revision 01.A.002/2019.10…
  • Page 14
    EN.IO.PMS-970 Pic. 8.13 Connection of power supply and 4 transmitters operating loads Pic. 8.14 Connection of power supply and 2 transmitters operating loads Revision 01.A.002/2019.10…
  • Page 15
    EN.IO.PMS-970 Pic. 8.15 Connection of power supply and 2 transmitters operating loads –OW version Transmitter output contacts are not equipped with quench circuit. When using transmitter outputs for switching inductive loads (contactor coils, transmitters, electromagnets, solenoids, etc.) it is required to use an additional quench circuit (typically a 47nF condenser/ min.
  • Page 16
    EN.IO.PMS-970 Tab. 8.1 Terminal assignment table Connector Symbol Terminal description Rating number POWER SUPPLY supply 230V/50Hz 230VAC version OPTIONAL: POWER SUPPLY supply 24V AC/DC 24VAC/DC version POWER 20 – 250V supply SUPPLY AC/DC OW version functional ground excitation output 24VDC…
  • Page 17: Technical Parameters

    EN.IO.PMS-970 TECHNICAL PARAMETERS CATEGORY PARAMETER VALUE COMMENTS accuracy +/-0.1% FS Temperature coefficient +/- 100ppm / °C Internal resolution 15 bit INPUT Sampling rate 16,6Hz Filter time constant 0-15,36s Noise rejection >=65dB f=50Hz Range 0..20mA -0.1 .. +21mA Input resistance <56Ω…

  • Page 18
    EN.IO.PMS-970 230VAC +10/-20% 20-250V AC/DC Voltage — AC 230V version OW version — AC/DC 24V version 20-35VDC 18-26VAC POWER SUPPLY — universal version 20-250V AC/DC OW version Power consumption <6W Digits / Colour 4 / Green LED PMS-970T DISPLAY Digit hight…
  • Page 19: Operation

    EN.IO.PMS-970 OPERATION 10.1. Programming Incorrect programming may cause incorrect read-out and uncontrolled output relay operations! The meter has many user-selected programme settings. All settings may be done with front panel push-buttons. Set-points levels are programmed directly in normal mode. Other settings require entering programme mode.

  • Page 20
    EN.IO.PMS-970 Tab. 10.1 Button function in programming mode Button Description Comments — scrolling up through menu functions and options ▲ — increasing numerical values — scrolling down through menu functions and options ▼ — decreasing numerical values — ESCAPE — go to previous menu level…
  • Page 21
    EN.IO.PMS-970 Ecod (4) Reset to factory all reset Fn09 setting serial comm. 01h -F7h — address Fc01 address (000-247) serial comm. 2.4, 4.8, 9.6, 19.2 Fc02 speed kbps no — no parity serial comm. Fc03 even — even parity even…
  • Page 22: Set-Point Programming

    EN.IO.PMS-970 Tab. 10.3 Meter’s programming example Menu Parameter Set value Settings function input type current Fn00 scaling points number Fn01 input range 4-20mA P01 : 04.00 : 0000 Fn02 P02 : 20.00 : 3000 display range 0-3000 decimal point position 000.0…

  • Page 23: Alternate Output Control

    EN.IO.PMS-970 10.3. Alternate output control PMS970 has built-in “alternate output control” function, called also “alternate lead/lag control”. While “A” option in Fn07 menu function is set, corresponding set-point belongs to “alternate output group”. The group may consist of 2, 3 or 4 set-points and relays but the relays are not dedicated to certain set-points.

  • Page 24: Serial Communication

    EN.IO.PMS-970 10.5. Serial communication PMS-970 has serial communication option with RS-485 internal module installed. The meter works with Modbus RTU protocol as slave device. Function 3 (register read) and function 16 (multiple registers write). The data exchanged with the meter are variable type “V” or parameters “P”.

  • Page 25
    EN.IO.PMS-970 During manual programming with front keys the meter returns exception code 0x06 (SLAVE_DEVICE_BUSY) and no other data. The same exception is returned during internal EEPROM write process. PMS-970 Modbus register assignment: Register Variable/ Default number/ Type Value range Comments…
  • Page 26
    EN.IO.PMS-970 400007/ Set-point P (R/W) -999 — 9999 0x0006 4 level (0xFC19- (0x01F4) 0x270F) 400008/ Output V (R) -32768 — 0x0007 current 32767 (0x8000- 0x7FFF) Minimum 400009/ P (R) -999 — 9999 0 (0x0000) 0x0008 read-out (0xFC19- 0x270F) 400100/ Maximum…
  • Page 27
    EN.IO.PMS-970 400033/ Identificat P (R) 0-65535 0 – no numberavailable 0x0020 (0x0000- number 0xFFFF) 400034/ Actual P (R) From 2 2 (0x0002) Actually defined Fn02 scaling 0x0021 (0x0002) to number of saling points. points Fn01 setting number 400035/ Input type P (R/W) 0 (0x0000) –…
  • Page 28
    EN.IO.PMS-970 400048/ Scaling P (R/W) 2-16 (0x0002 2 (0x0002) Fn01 0x002F points — 0x0010) number 400049/ P01 input P (R/W) -999 — 9999 0 (0x0000) Fn02:P01 0x0030 value (0xFC19- 0x270F) 400050/ P01 read- P (R/W) -999 — 9999 0 (0x0000) Fn02:P01…
  • Page 29
    EN.IO.PMS-970 400065/ P09 input P (R/W) -999 — 9999 25000 Fn02:P09 0x0040 value (0xFC19- (0x61A8) 0x270F) 400066/ P09 read- P (R/W) -999 — 9999 25000 Fn02:P09 out value 0x0041 (0xFC19- (0x61A8) 0x270F) 400067/ P10 input P (R/W) -999 — 9999…
  • Page 30
    EN.IO.PMS-970 400082/ Read-out P (R/W) -999 — 9999 2000 Fn08:P02 0x0051 linear (0xFC19- (0x07D0) output 0x270F) 400083/ Low linear P (R/W) -999 — 9999 Fn08:P01 ( default 4.00mA ) 0x0052 output (0xFC19- (0x0190) value 0x270F) 400084/ High P (R/W) -999 — 9999 2000 Fn08:P02 ( default 20.00mA )
  • Page 31: Display Test

    EN.IO.PMS-970 10.6. Display test PMS970 has special test procedure for LED display, relays and version check. The test is initiated when the meter is powered-up with key pressed. LED segments are lighted-up in following cycle: — four digit meter version code,…

Table of Contents for Aplisens PMS-970:

  • EN.IO.PMS-970 29 Revision 01.A.002/2019.10 10.6. Display test PMS970 has special test procedure for LED display, relays and version check. The test is initiated when the meter is powered-up with key pressed. LED segments are lighted-up in following cycle: — four digit meter version code, — digital display (all segments simultaneously), — alarm leds with output relays activation, — bargraph green (all segments simultaneously), — bargraph red (all segments simultaneously). The ENT key toggles betwe

  • EN.IO.PMS-970 8 Revision 01.A.002/2019.10 Pic. 8.2 Description of terminals for OW standard version (see nameplate) Pic. 8.3 Description of terminals for standard version

  • EN.IO.PMS-970 22 Revision 01.A.002/2019.10 10.5. Serial communication PMS-970 has serial communication option with RS-485 internal module installed. The meter works with Modbus RTU protocol as slave device. Function 3 (register read) and function 16 (multiple registers write). The data exchanged with the meter are variable type “V” or parameters “P”. Parameters are also accessible from programming menu. Variables are read-only (R). Parameters are read-only type (R) or read/write type

  • EN.IO.PMS-970 20 Revision 01.A.002/2019.10 Tab. 10.3 Meter’s programming example Parameter Set value Menu function Settings input type current Fn00 I scaling points number 2 Fn01 2 input range 4-20mA Fn02 P01 : 04.00 : 0000 P02 : 20.00 : 3000 display range 0-3000 decimal point position 000.0 Fn03 000.0 rounding none Fn04 1 filter time constant 240ms Fn05 3 AL1 „ON” level >2500 (1) AL1 : 2500 AL2 „ON” level <1000 (1) AL2 : 1000

  • Symbols used Symbol Description Carefully follow the information in this document to ensure safety and full functionality of the device. Information particularly useful for the installation and use of the device. Information particularly useful for the installation and use of the Ex type device Information on the disposal of used equipment. BASIC REQUIREMENTS AND SAFETY OF USE  The manufacturer takes no liability for damage resulting from incorrect

  • EN.IO.PMS-970 15 Revision 01.A.002/2019.10 9. TECHNICAL PARAMETERS CATEGORY PARAMETER VALUE COMMENTS INPUT accuracy +/-0.1% FS Temperature coefficient +/- 100ppm / °C Internal resolution 15 bit Sampling rate 16,6Hz Filter time constant 0-15,36s Noise rejection >=65dB f=50Hz CURRENT INPUT Range 0..20mA -0.1 .. +21mA Input resistance <56Ω Max. input current Internally limited Ov

  • EN.IO.PMS-970 23 Revision 01.A.002/2019.10 During manual programming with front keys the meter returns exception code 0x06 (SLAVE_DEVICE_BUSY) and no other data. The same exception is returned during internal EEPROM write process. PMS-970 Modbus register assignment: Register number/ address Variable/ parameter Type Value range Default value Comments 400002/ 0x0001 Digital read-out V (R) -99

  • EN.IO.PMS-970 7 Revision 01.A.002/2019.10 Due to possible significant interference occurring in industrial systems, use adequate precautions that ensure proper operation of the device. Disregarding the following tips may, in certain circumstances, lead to exceeding the levels of electromagnetic disturbance for a typical industrial environment, which in turn may cause incorrect readout on the device

  • EN.IO.PMS-970 4 Revision 01.A.002/2019.10 7. INSTALLATION The device is designed and made in a way that provides maximum safety of use and resistance to interference that occur in a typical industrial environment. For these features to be fully used, the installation of the device should be conducted properly, according to the relevant standards.  Prior to installation, read the basic safety requirements on page 3.  Prior to connecting the device to the electrical syst

  • EN.IO.PMS-970 6 Revision 01.A.002/2019.10 8. CONNECTING Clamp no. 3 is the functional grounding clamp. Grounding the clamp is necessary for protection against interference. The clamp is also used for connecting the shields of measuring wires. All connection and installation steps must be performed with power discon

  • EN.IO.PMS-970 10 Revision 01.A.002/2019.10 Pic. 8.7 Connection of 2-lead current transmitters Pic. 8.8 Connection of 3-lead OW current transmitters Pic. 8.9 Connection of 3-lead current transmitters

  • EN.IO.PMS-970 3 Revision 01.A.002/2019.10 4. TRANSPORT AND STORAGE 4.1. Transport When transported, the meters should be packed in individual and/or group packaging and carried on a covered means of transport. The packaging should be secured against shifting and atmospheric weather effects. 4.2. Storage The meter should be stored in the manufacturer’s packaging, in a covered room, free of

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of Aplisens PMS-970 device using right now.

Specifications:

1546/1546326-pms970.pdf file (10 Sep 2022)

Accompanying Data:

Aplisens PMS-970 Measuring Instruments PDF Operation & User’s Manual (Updated: Saturday 10th of September 2022 05:47:03 AM)

Rating: 4.6 (rated by 75 users)

Compatible devices: SGE-25.Modbus, ADR Series, SGE-25.SMART, SGE-25, CS-27/W, WW-30, Moistick digital, MS-100K.

Recommended Documentation:

Aplisens PMS-970: Text of Operation & User’s Manual

(Ocr-Read Version Summary of Contents, UPD: 10 September 2022)

  • 18, EN.IO.PMS-970 16 Revision 01.A.002/2019.10 POWER SUPPLY Voltage — AC 230V version 230VAC +10/-20% 20-250V AC/DC OW version — AC/DC 24V version 20-35VDC 18-26VAC — universal version 20-250V AC/DC OW version Power consumption <6W DISPLAY Digits / Colour 4 / Green LED Digit hight 7mm PMS-970T 20mm PMS-970P …

  • 26, EN.IO.PMS-970 24 Revision 01.A.002/2019.10 400007/ 0x0006 Set-point 4 level P (R/W) -999 — 9999 (0xFC19- 0x270F) 500 (0x01F4) AL4 400008/ 0x0007 Output current V (R) -32768 — 32767 (0x8000- 0x7FFF) — *10 -3 mA 400009/ 0x0008 Minimum read-out P (R) -999 — 9999 (0xFC19- 0x270F) 0 (0x0000) 400100/ 0x0009 Maximum read-ou…

  • 5, EN.IO.PMS-970 3 Revision 01.A.002/2019.10 4. TRANSPORT AND STORAGE 4.1. Transport When transported, the meters should be packed in individual and/or group packaging and carried on a covered means of transport. The packaging should be secured against shifting and atmospheric weather effects. 4.2. Storage The meter should be stored in the…

  • 24, EN.IO.PMS-970 22 Revision 01.A.002/2019.10 10.5. Serial communication PMS-970 has serial communication option with RS-485 internal module installed. The meter works with Modbus RTU protocol as slave device. Function 3 (register read) and function 16 (multiple registers write). The data exchanged with the meter are variable type “V” or parameters…

  • 1, USER’S MANUAL PMS-970 Programmable Meter Firmware: from v.5.00 EN.IO.PMS-970 OCTOBER 2019 APLISENS S.A., 03-192 Warsaw, ul. Morelowa 7 tel. +48 22 814 07 77; fax +48 22 814 07 78 www.aplisens.pl, e-mail: [email protected] Revision 01.A.002

  • 6, EN.IO.PMS-970 4 Revision 01.A.002/2019.10 7. INSTALLATION The device is designed and made in a way that provides maximum safety of use and resistance to interference that occur in a typical industrial environment. For these features to be fully used, the installation of the device should be conducted properly, according to the relevant standards…

  • 4, EN.IO.PMS-970 2 Revision 01.A.002/2019.10 1. INTRODUCTION The subject of this instruction manual is the PMS-970 programmable meter. The manual includes data, hints, and recommended action for installation and usage of the meter, as well as troubleshooting tips. 2. SAFETY  Read this instruction carefully prior to, installation, startup, or any other work.  Installation …

  • 22, EN.IO.PMS-970 20 Revision 01.A.002/2019.10 Tab. 10.3 Meter’s programming example Parameter Set value Menu function Settings input type current Fn00 I scaling points number 2 Fn01 2 input range 4-20mA Fn02 P01 : 04.00 : 0000 P02 : 20.00 : 3000 display range 0-3000 decimal point position 000.0 Fn03 000.0 rounding none …

  • 28, EN.IO.PMS-970 26 Revision 01.A.002/2019.10 400048/ 0x002F Scaling points number P (R/W) 2-16 (0x0002 — 0x0010) 2 (0x0002) Fn01 400049/ 0x0030 P01 input value P (R/W) -999 — 9999 (0xFC19- 0x270F) 0 (0x0000) Fn02:P01 400050/ 0x0031 P01 read- out value P (R/W) -999 — 9999 (0xFC19- 0x270F) 0 (0x0000) Fn02:P01 400051…

  • 3, EN.IO.PMS-970 1 Revision 01.A.002/2019.10 TABLE OF CONTENTS 1. INTRODUCTION …………………………………………………………………………………………….. 2 2. SAFETY ………………………………………………………………………………………………………… 2 3. SET LIST ………………….…

Aplisens PMS-970: Recommended Instructions

Polaris PMX-P2, FH-2050, GLTF2940ES0, RuggedNet GPoE+/Mi

  • Revision Date: October 26, 2020 PMC-53M-A Quick Start Guide Version V1.02 Package Contents a. PMC-53M-A with all mounting clips and plug-in connectors installed b. Factory Test Report c. CD with PMC-53M-A User Manual d. Quick Start Guide (this document) Meter Overview Front View Rear View — 4DI, 2DO, RS-485 …

    PMC-53M-A 2

  • PAGE 19070 Vibration Analysis Copyright © 2012 Test Products International, Inc.9070 Smart Vibration Meter Instruction ManualOverall machine and bearing conditions:vibration values are displayedwith color coded alarm levelsfor ISO values and BearingDamage (BDU).Easy vibrationanalysis:1X (unbalance)2X (misalignment)3X (looseness)Identify complexissues:100 to 800-lin …

    9070 16

  • IM CA12E-02E <Page 1>To return to the previous step:<9> To return to the previous step without xing the setting, press and hold the input cancellation key for about 1 second. Note that this is possible only before writing to the EEPROM.To return to the nomal operation mode:<10> Simultaneously press and hold the keys (shown in the gure in the “A …

    CA12E HANDY CAL 2

  • DL489 True RMS600V 600A CAT IIICATII 1000V CATIII 600VMAX30VT2T1TEMPNCVMAX/MINPEAKDCZeroINRUSHTemp/°F°C μA AVHz/DutyMFDRANGEINSTRUCTION MANUALENGLISHDL489Commemorative Edition True RMS Digital Clamp-On Meter1000VCAT II600VCAT III99 Washington Street Melrose, MA 02176 Phone 781-665-1400Toll Free 1-800-517-8431Visit us at www.TestEquipmentDepot.com …

    DL489 16

  • ZoomH4NTroubleshootingGuideProblem:TheH4NisonlypickingupaudioinonechannelwhenIpluginanXLR.● Solution:Ensurethatmonomixisturnedon.Thisfeatureislocatedundertheinputtabinthemenu.Problem:Idon’thearanyaudiothroughmyheadphones.� …

    H4N 2

  • PQMPower Quality Meter™INSTRUCTION MANUALSoftware Revision: 3.5xManual P/N: 1665-0003-CGManual Order Code: GEK-106296ACopyright © 2001 GE Power ManagementGE Power Management215 Anderson Avenue, Markham, OntarioCanada L6E 1B3Tel: (905) 294-6222 Fax: (905) 294-8512Internet: http://www.GEindustrial.com/pmManufactured under anISO9001 Registered system.gGE Power Manageme …

    Power Quality Meter Series 282

  • Quick-Start InstructionsHINTS: Prepare the area by creating a grid pattern prior to testing.Perform all Scans on like-surfaced areas such as asphalt, concrete, rock, grass.Always perform multiple scans.Do not test on expansion joints or cracks in the surface.Hold the APL as straight up as possible.TERMS: Slice – individual test pointScan – A series of slices along a single li …

    ULTRA-TRAC APL 2

  • SQM-LU Operator’s Manualc Copyright 2005 — 2017Version: 20170728Company informationMailing address Unihedron4 Lawrence AvenueGrimsby, Ontario L3M 2L9CanadaTelephone (905) 945-1197Fax (905) 945-6770Website unihedron.com …

    SQM-LU 67

Additional Information:

Popular Right Now:
Operating Impressions, Questions and Answers:

Понравилась статья? Поделить с друзьями:
  • Аис город руководство
  • Лунфей 2 квт инструкция по установке
  • Lego creator 31088 инструкция кашалот скачать
  • Окситетрациклин 200 инструкция по применению в ветеринарии для коров
  • Head booster инструкция по применению на русском языке