Technical Information

Proline Prowirl 72F, 72W, 73F, 73W

Vortex Flow Measuring System

Reliable flow measurement of gas, steam and liquids

Application

For the universal measurement of the volume flow

of gases, steam and liquids.

With integrated T-measurement, the mass flow of steam,

water (as per IAPWS-IF97 ASME), natural gas (as per

AGA NX-19), compressed air and other gases and liquids

can be measured.

Maximum range of applications thanks to:

• Fluid temperature range from –200…+400 °C

• Pressure ratings up to PN250/Cl 1500

Approvals for hazardous areas:

• ATEX, FM, CSA, TIIS

Connection to all common process control systems:

• HART, PROFIBUS PA, FOUNDATION Fieldbus

Relevant safety aspects:

• Pressure Equipment Directive

• Up to SIL 2

TI070D/06/en/12.05

71005481

Your benefits

The robust Prowirl sensor, tried and tested in over

100,000 applications offers:

• High resistance to:

– Vibrations (over 1 g in all axes)

– Temperature shocks (> 150 K/s)

– Contaminated media

– Water hammer

• No maintenance, no moving parts, no zero-point drift.

• Software initial settings save time and costs

In addition, Prowirl devices offer the following

possibilities:

• Complete saturated steam or liquid-mass measuring

point in one single device

• Calculation of the mass flow from the measured

variables volume flow and temperature in the

integrated flow computer

• External pressure value read-in for superheated steam

and gas applications (optional)

• External temperature value read-in for delta heat

measurement (optional)

loading

Summary of Contents for Endress+Hauser Proline Prowirl 72F

Обратный звонок

Представьтесь, мы вам перезвоним.

Оставить свой отзыв

Расскажите о своём опыте работы с нами.

Задать вопрос

Менеджеры компании с радостью ответят на ваши вопросы, произведут расчет стоимости услуг и подготовят индивидуальное коммерческое предложение.

<a href=»/f1/s/16/557/basic/1504/16/BA084DRU.pdf?t=1483033874″ target=»_blank»>Скачать файл: Вихревой расходомер Prowirl 72F,73F</a>

  • 15, Proline Prowirl 72F, 72W, 73F, 73W Endress+Hauser 15 Inlet and outlet run As a minimum, the inlet and outlet runs shown below must be observed to achieve the specified accuracy of the device. The longest inlet run shown must be observed if two or more flow disturbances are present. A0001867 Minimum inlet and outlet runs with various flow obstructions A = Inlet run B = Outlet run 1 = Re…

  • 17, Proline Prowirl 72F, 72W, 73F, 73W Endress+Hauser 17 Operating conditions: environment Ambient temperature range • Compact version: –40…+70 °C (EEx-d version: –40…+60 °C; ATEX II 1/2 GD version/dust ignition-proof: –20…+55 °C) Display can be read between –20 °C…+70 °C • Remote version: Sensor –40…+85 °C (ATEX II 1/2 GD version/dust ignition-proof: –20…+55 …

  • 4, Proline Prowirl 72F, 72W, 73F, 73W 4 Endress+Hauser The capacitive sensor The sensor of a vortex flowmeter has a major influence on the ability, robustness and reliability of the whole measuring system. The robust DSC sensor — with an integrated temperature sensor (Pt 1000) with Prowirl 73 — is burst-tested and vibration and temperature-shock-tested (temperature shocks of 150 K/s). The Prowi…

  • 28, Proline Prowirl 72F, 72W, 73F, 73W 28 Endress+Hauser Prowirl 72F Dualsens version to JIS B2238 DN Pressure rating d D H L X Weight DIN/JIS [mm] [mm] [mm] [mm] [mm] [kg] 40 Schedule 40 20K 41.2 140.0 303 200 31 16 Schedule 80 20K 38.1 140.0 40K 38.1 160.0 17 50 Schedule 40 10K 52.7 155.0 310 200 33 18 20K 52.7 155.0 Schedule 80 10K 49.2 155.0 20K 49.2 155.0 40K 49.2 165.0 80 Schedule 4…

  • 20, Proline Prowirl 72F, 72W, 73F, 73W 20 Endress+Hauser Pressure-temperature curve to ANSI B16.5 and JIS B2238, stainless steel ANSI B 16.5: Class 150…300 → Prowirl 73W and 73F Class 600 → Prowirl 73F (in development) JIS B2238 10…20 K → Prowirl 73W and 73F 40 K → Prowirl 73F (in development) A0001923 Pressure loss The pressure loss can be determined with the aid o…

  • 14, Proline Prowirl 72F, 72W, 73F, 73W 14 Endress+Hauser Piping insulation When insulating, please ensure that a sufficiently large area of the housing support is exposed. The uncovered part serves as a radiator and protects the electronics from overheating (or undercooling). The maximum insulation height permitted is illustrated in the diagrams. These apply equally to both the compact ve…

  • 18, Proline Prowirl 72F, 72W, 73F, 73W 18 Endress+Hauser Fluid pressure Prowirl 72 Pressure-temperature curve to EN (DIN), stainless steel PN 10…40 → Prowirl 72W and 72F PN 63…250 → Prowirl 72F A0003238 Pressure-temperature curve to ANSI B16.5, stainless steel ANSI B16.5: Class 150…300 → Prowirl 72W and 72F Class 600…1500 → Prowirl 72F A0003402 -200 -100 0 20 40…

  • 33, Proline Prowirl 72F, 72W, 73F, 73W Endress+Hauser 33 Accessories • Spare parts as per separate price list • Wafer version mounting set • Pipe and wall mounting kit for transmitter remote version DK5WM-B • Replacement transmitter • Universal flow and energy computer RMC 621 • Steam computer RMS 621 • Flow conditioner • HART Communicator DXR 375 handheld t…

  • 19, Proline Prowirl 72F, 72W, 73F, 73W Endress+Hauser 19 Pressure-temperature curve to JIS B2238 and butt-weld version, stainless steel: A0003404 Pressure-temperature curve to EN (DIN), ANSI B16.5 and JIS B2238, Alloy C-22 PN 16…40, Class 150…300, 10…20K → Prowirl 72F A0003395 Prowirl 73 Pressure-temperature curve to EN (DIN), stainless steel PN 10…40 → Prowirl 73W and …

  • 26, Proline Prowirl 72F, 72W, 73F, 73W 26 Endress+Hauser Dimensions of Prowirl 72F, Dualsens version Flanged version to: • EN 1092-1 (DIN 2501), Ra = 6.3…12.5 mm • Raised face to: – EN 1092-1 Form B1 (DIN 2526 Form C), PN 10…40, Ra = 6.3…12.5 mm, optional with groove to EN1091-1 Form D (DIN 2512 Form N) – EN 1092-1 Form B2 (DIN 2526 Form E), PN 63…100, Ra = 1.6…3.2 mm 1) 2) …

  • 29, Proline Prowirl 72F, 72W, 73F, 73W Endress+Hauser 29 Dimensions of flow conditioner (accessory) Dimensions to: • EN 1092-1 (DIN 2501) • ANSI B16.5 • JIS B2238 Material 1.4435 (316L), in conformity with NACE MR 0175 and MR 0103 A0001941 D1: The flow conditioner is fitted at the external diameter between the bolts. D2: The flow conditioner is fitted at the indentations between…

  • 3, Proline Prowirl 72F, 72W, 73F, 73W Endress+Hauser 3 Function and system design Measuring principle Vortex meters work on the principle of the Karman vortex street. When luid flows past a bluff body, vortices are alternately formed on both sides with opposite directions of rotation. These vortices each generate a local low pressure. The pressure fluctuations are recorded by the senso…

  • 13, Proline Prowirl 72F, 72W, 73F, 73W Endress+Hauser 13 Operating conditions: installation Installation instructions Vortex meters require a fully developed flow profile as a prerequisite for correct volume flow measurement. For this reason, please note the following points when installing the device: Orientation The device can generally be installed in any position…

  • 31, Proline Prowirl 72F, 72W, 73F, 73W Endress+Hauser 31 Certificates and approvals CE mark The device is in conformity with the statutory requirements of the EC Directives. Endress+Hauser confirms successful testing of the device by affixing the CE mark. C-tick The measuring system is in conformity with the EMC requirements of the Australian Communications Authority (ACA). Ex-approva…