Robustel r3000 3p инструкция на русском

Robustel R3000-3P User Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

User Guide

R3000

Industrial Dual SIM Cellular VPN Router

2 Eth + 1 RS-232 + 1 RS-485 + 1 USB Host

Guangzhou Robustel Technologies Co., Limited

www.robustel.com

loading

Related Manuals for Robustel R3000-3P

Summary of Contents for Robustel R3000-3P

  • Page 1: User Guide

    User Guide R3000 Industrial Dual SIM Cellular VPN Router 2 Eth + 1 RS-232 + 1 RS-485 + 1 USB Host Guangzhou Robustel Technologies Co., Limited www.robustel.com…

  • Page 2
    The contents of this document are subject to change without notice due to continued progress in methodology, design and manufacturing. Robustel shall have no liability for any error or damage of any kind resulting from the use of this document.
  • Page 3
    Robustel accepts no responsibility for damages of any kind resulting from delays or errors in data transmitted or received using the router, or for failure of the router to transmit or receive such data.
  • Page 4
    Robustel GoRugged R3000 User Guide Protecting Your Router To ensure error-free usage, please install and operate your router with care. Do remember the following: Do not expose the router to extreme conditions such as high humidity / rain, high temperature, direct sunlight, …
  • Page 5
    Robustel GoRugged R3000 User Guide Regulatory and Type Approval Information Table 1: Directives 2011/65/EC Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and…
  • Page 6
    Robustel GoRugged R3000 User Guide Document History Updates between document versions are cumulative. Therefore, the latest document version contains all updates made to previous versions. Date Firmware Version Doc Version Change Description 27 March, 2017 3.0.0 v.4.0.0 Initial release RT_UG_R3000_v.4.0.0…
  • Page 7: Table Of Contents

    Robustel GoRugged R3000 User Guide Contents Chapter 1 Product Concept ……………………..8 Key Features …………………………. 8 Package Contents ……………………….9 Specifications ……………………….11 Dimensions …………………………. 13 Ordering Information ……………………..14 Chapter 2 Hardware Installation ……………………15 LED Indicators ……………………….15 PIN Assignment ……………………….

  • Page 8
    Robustel GoRugged R3000 User Guide 3.25 Services > DDNS ……………………….94 3.26 Services > SSH……………………….95 3.27 Services > GPS ……………………….96 3.28 Services > Web Server ……………………..99 3.29 Services > Advanced ……………………..100 3.30 System > Debug ……………………….102 3.31…
  • Page 9: Chapter 1 Product Concept

    Robustel GoRugged R3000 User Guide Chapter 1 Product Concept 1.1 Key Features Robustel GoRugged R3000 is a rugged cellular router offering state-of-the-art mobile connectivity for machine to machine (M2M) applications.  Supports WWAN1, WWAN2, Ethernet WAN, WLAN WAN link backup and ICMP detection …

  • Page 10: Package Contents

    1 x 7-pin pluggable terminal block with lock for serial port, I/O and console port  1 x Quick Start Guide with download link of other documents or tools Note: If any of the above items is missing or damaged, please contact your Robustel sales representative. RT_UG_R3000_v.4.0.0 27 March, 2017…

  • Page 11
    Robustel GoRugged R3000 User Guide Optional accessories (sold separately):  SMA cellular antenna (3G/4G)  RP-SMA Wi-Fi antenna (stubby antenna or magnet antenna optional) Stubby antenna Magnet antenna  Wall mounting kit  35 mm DIN rail mounting kit …
  • Page 12: Specifications

    Robustel GoRugged R3000 User Guide  AC/DC power adapter (12V DC, 1.5 A; EU/US/UK/AU plug optional) 1.3 Specifications Cellular Interface Number of ports: 2 (AUX + MAIN)  Connector: SMA, female  Standards: GSM/GPRS/EDGE/UMTS/TD-SCDMA/HSPA+/LTE  GSM: max DL/UL = 9.6/2.7 Kbps GPRS: max DL/UL = 86 Kbps EDGE: max DL/UL = 236.8 Kbps…

  • Page 13
    Management: Web, CLI, SNMP v1/v2/v3, SMS, RobustLink  Serial port: TCP Client/Server, UDP, Modbus RTU/ASCII to Modbus TCP, Virtual COM (COM port redirector)  RobustLink: a centralized M2M management platform developed by Robustel  RobustVPN: a Cloud VPN Portal developed by Robustel …
  • Page 14: Dimensions

    Robustel GoRugged R3000 User Guide Power Supply and Consumption Connector: 5 mm terminal block with lock  Input voltage: 9 to 60V DC Power consumption: Idle: 100 mA@12 V  Data link: 400 mA (peak) @12 V Physical Characteristics Ingress protection: IP30 …

  • Page 15: Ordering Information

    Robustel GoRugged R3000 User Guide 1.5 Ordering Information Model No. Frequency Bands Operating Environment R3000-3P HSPA+ Router (Mini PCIe) -40 to 85°C/5 to 95% RH HSDPA/HSUPA/HSPA+: 800/850/900/AWS/1900/2100 MHz GSM/GPRS/EDGE: 850/900/1800/1900 MHz R3000-4L LTE Router (Mini PCIe) -40 to 85°C/5 to 95% RH…

  • Page 16: Chapter 2 Hardware Installation

    Robustel GoRugged R3000 User Guide Chapter 2 Hardware Installation 2.1 LED Indicators Name Color Status Description Green On, fast blinking Router is powered on (the system is initializing) (250 mSec blink time) On, slow blinking Router starts operating (500 mSec blink time)

  • Page 17: Pin Assignment

    Robustel GoRugged R3000 User Guide module found but AT command failed no SIM card inserted110 need to enter the PIN code need to enter the PUK code registration failed no module found not support the module Note: You can choose the display type of USR LED. For more details, please refer to 3.29 Service > Advanced.

  • Page 18: Usb Interface

    Robustel GoRugged R3000 User Guide 2.3 USB Interface Function Operation Firmware USB interface is used for batch firmware upgrading, but upgrade cannot be used for sending or receiving data from slave devices which connected to it. You can insert a USB storage device into the router’s USB interface, such as a U disk or a…

  • Page 19: Ethernet Ports

    Robustel GoRugged R3000 User Guide 2.5 Ethernet Ports R3000 Router has two Ethernet ports, including ETH0 and ETH1. Each Ethernet port has two LED indicators (refer to the left figure). The yellow one is Link Indicator, while the green one is Speed Indicator. For details about status, see the table below.

  • Page 20
    Robustel GoRugged R3000 User Guide To remove slot cover, loosen the screws associated with the cover by using a screwdriver and then find the SIM card slot/SD card slot. To insert SIM card/Micro SD card, press the card with finger until you hear a click and then tighten the screws associated with the cover by using a screwdriver.
  • Page 21: Attach External Antenna (Sma Type)

    Robustel GoRugged R3000 User Guide 2.7 Attach External Antenna (SMA Type) Attach the SMA external antenna to the router’s connector and twist tightly. Make sure the antenna is within the correct frequency range provided by the ISP and with 50 Ohm impedance.

  • Page 22
    Robustel GoRugged R3000 User Guide DIN rail mounting DIN rail size (measured in mm) Use 3 pcs of M3*6 flat head Phillips screws to fix the DIN rail to the router, and then hang the DIN rail on the mounting bracket. It is necessary to choose a standard bracket.
  • Page 23: Ground The Router

    Robustel GoRugged R3000 User Guide 2.9 Ground the Router Router grounding helps prevent the noise effect due to electromagnetic interference (EMI). Connect the router to the site ground wire by the ground screw before powering on. Ground Screw Note: This product is appropriate to be mounted on a sound grounded device surface, such as a metal panel.

  • Page 24: Power Supply

    Robustel GoRugged R3000 User Guide 2.11 Power Supply R3000 Router supports reverse polarity protection, but always refers to the figure above to connect the power adapter correctly. There are two cables associated with the power adapter. Following to the color of the head, connect the cable marked red to the positive pole through a terminal block, and connect the yellow one to the negative in the same way.

  • Page 25: Chapter 3 Initial Configuration

    Robustel GoRugged R3000 User Guide Chapter 3 Initial Configuration The router can be configured through your web browser that including IE 8.0 or above, Chrome and Firefox, etc. A web browser is included as a standard application in the following operating systems: Linux, Mac OS, Windows 98/NT/2000/XP/Me/Vista/7/8, etc.

  • Page 26
    Robustel GoRugged R3000 User Guide Click Properties in the window of Local Area Connection Status. Choose Internet Protocol Version 4 (TCP/IPv4) and click Properties. RT_UG_R3000_v.4.0.0 27 March, 2017 25/136 Confidential…
  • Page 27
    Robustel GoRugged R3000 User Guide Two ways for configuring the IP address of PC Obtain an IP address automatically: Use the following IP address: (Configured a static IP address manually within the same subnet of R3000 Router) Click OK to finish the configuration.
  • Page 28: Factory Default Settings

    Robustel GoRugged R3000 User Guide 3.2 Factory Default Settings Before configuring your router, you need to know the following default settings. Item Description Username admin Password admin ETH0 192.168.0.1/255.255.255.0, LAN mode ETH1 192.168.0.1/255.255.255.0, LAN mode DHCP Server Enabled 3.3 Log in the Router To log in to the management page and view the configuration status of your router, please follow the steps below.

  • Page 29: Control Panel

    Robustel GoRugged R3000 User Guide 3.4 Control Panel After logging in, the home page of the R3000 Router’s web interface is displayed, for example. Using the original password to log in the router, the page will pop up the following tab It is strongly recommended for security purposes that you change the default username and/or password.

  • Page 30: Status

    Robustel GoRugged R3000 User Guide Submit Click to save the modification on current configuration page. Cancel Click to cancel the modification on current configuration page. Note: The steps of how to modify configuration are as bellow: Modify in one page;…

  • Page 31: Internet Status

    Robustel GoRugged R3000 User Guide Firmware Version Show the firmware version running on the router. Hardware Version Show the current hardware version. Kernel Version Show the current kernel version. Serial Number Show the serial number of your device. Internet Status…

  • Page 32: Interface > Link Manager

    Robustel GoRugged R3000 User Guide 3.6 Interface > Link Manager This section allows you to setup the link connection. General Settings @ Link Manager Item Description Default Primary Link Select from “WWAN1”, “WWAN2”, “WAN” or “WLAN”. WWAN1  WWAN1: Select to make SIM1 as the primary wireless link …

  • Page 33
    Robustel GoRugged R3000 User Guide Link Settings allows you to configure the parameters of link connection, including WWAN1/WWAN2, WAN and WLAN. It is recommended to enable Ping detection to keep the router always online. The Ping detection increases the reliability and also costs the data traffic.
  • Page 34
    Robustel GoRugged R3000 User Guide The window is displayed as below when disabling the “Automatic APN Selection” option. Link Settings (WWAN) Item Description Default General Settings Index Indicate the ordinal of the list. Type Show the type of the link.
  • Page 35
    Robustel GoRugged R3000 User Guide Link Settings (WWAN) Item Description Default WWAN Settings Automatic APN Click the toggle button to enable/disable the “Automatic APN Selection” Selection option. After enabling, the device will recognize the access point name automatically. Alternatively, you can disable this option and manually add the access point name.
  • Page 36
    Robustel GoRugged R3000 User Guide Link Settings (WWAN) Item Description Default Overrided Primary Override primary DNS will override the automatically obtained DNS. Null Overrided Secondary Override secondary DNS will override the automatically obtained DNS. Null Debug Enable Click the toggle button to enable/disable this option. Enable for debugging information output.
  • Page 37
    Robustel GoRugged R3000 User Guide The window is displayed as below when choosing “PPPoE” as the connection type. Link Settings (WAN) Item Description Default General Settings Index Indicate the ordinal of the list. Type Show the type of the link.
  • Page 38
    Robustel GoRugged R3000 User Guide Connection Type Select from “DHCP”, “Static” or “PPPoE”. DHCP Static Address Settings IP Address Set the IP address with Netmask which can access the internet. Null IP address with Netmask, e.g. 192.168.1.1/24 Gateway Set the gateway of the IP address in WAN port.
  • Page 39
    Robustel GoRugged R3000 User Guide WLAN Router will obtain IP automatically from the WLAN AP if choosing “DHCP” as the connection type. The specific parameter configuration of SSID is shown as below. The window is displayed as below when choosing “Static” as the connection type.
  • Page 40
    Robustel GoRugged R3000 User Guide Link Settings (WLAN) Item Description Default General Settings Index Indicate the ordinal of the list. Type Show the type of the link. WLAN Description Enter a description for this link. Null Connection Type Select from “DHCP” or “Static”.
  • Page 41
    Robustel GoRugged R3000 User Guide Secondary DNS Set the secondary DNS. Null Ping Detection Settings Enable Click the toggle button to enable/disable the ping detection mechanism, a keepalive policy of R3000 Router. Primary Server Router will ping this primary address/domain name to check that if the 8.8.8.8…
  • Page 42
    Robustel GoRugged R3000 User Guide Click the row of the link, and it will show the details information of the current link connection under the row. Click the button to clear SIM1 or SIM2 monthly data traffic usage statistics. Data statistics will be displayed only if enable the Data Allowance function in Interface >…
  • Page 43: Interface > Lan

    Robustel GoRugged R3000 User Guide 3.7 Interface > LAN This section allows you to set the related parameters for LAN port. There are two LAN ports on R3000 Router, including ETH0 and ETH1. The default settings of ETH0 and ETH1 are lan0, and their default IP are 192.168.0.1/255.255.255.0.

  • Page 44
    Robustel GoRugged R3000 User Guide The window is displayed as below when choosing “Server” as the mode. The window is displayed as below when choosing “Relay” as the mode. Item Description Default DHCP Settings Enable Click the toggle button to enable/disable the DHCP function.
  • Page 45
    Robustel GoRugged R3000 User Guide Item Description Default IP Pool End Define the end of the pool of IP addresses which will be leased to 192.168.0.100 DHCP clients. Subnet Mask Define the subnet mask of IP address obtained by DHCP clients from 255.255.255.0…
  • Page 46
    Robustel GoRugged R3000 User Guide IP Settings Item Description Default Index Indicate the ordinal of the list. Interface Show the editing port, read only. lan0 IP Address Set the multiple IP address of the LAN port. Null Netmask Set the multiple Netmask of the LAN port.
  • Page 47: Interface > Ethernet

    Robustel GoRugged R3000 User Guide Status This section allows you to view the status of LAN connection. Click the row of status, the details status information will be display under the row. Please refer to the screenshot below. 3.8 Interface > Ethernet This section allows you to set the related parameters for Ethernet.

  • Page 48
    Robustel GoRugged R3000 User Guide This section introduces you to set the parameters of the WAN port. Click button of eth0 to configure its parameters. The port assignment can be changed by selecting from the drop down list. Port Settings…
  • Page 49: Interface > Cellular

    Robustel GoRugged R3000 User Guide This column allows you to view the status of Ethernet port. Click the row of status, the details status information will be display under the row. Please refer to the screenshot below. 3.9 Interface > Cellular This section allows you to set the related parameters of Cellular.

  • Page 50
    Robustel GoRugged R3000 User Guide The window is displayed as below when choosing “Auto” as the network type. The window is displayed as below when choosing “Specify” as the band select type. Cellular Item Description Default General Settings RT_UG_R3000_v.4.0.0 27 March, 2017…
  • Page 51
    Robustel GoRugged R3000 User Guide Cellular Item Description Default Index Indicate the ordinal of the list. SIM Card Set the currently editing SIM card. SIM1 Phone Number Enter the phone number of the SIM card. Null PIN Code Enter a 4-8 characters PIN code used for unlocking the SIM.
  • Page 52
    Robustel GoRugged R3000 User Guide Click the row of status, the details status information will be displayed under the row. Status Item Description Index Indicate the ordinal of the list. Modem Status Show the status of the radio module. Modem Model Show the model of the radio module.
  • Page 53: Interface > Wi-Fi

    Robustel GoRugged R3000 User Guide Status Item Description IMEI Show the IMEI (International Mobile Equipment Identity) number of the radio module. Firmware Version Show the current firmware version of the radio module. This page allows you to check the AT Debug.

  • Page 54
    Robustel GoRugged R3000 User Guide Click the Access Point column to configure the parameters of Wi-Fi AP. By default, the security mode is set as “Disabled”. The window is displayed as below when setting “WPA” as the security mode. RT_UG_R3000_v.4.0.0…
  • Page 55
    Robustel GoRugged R3000 User Guide The window is displayed as below when setting “WEP” as the security mode. General Settings @ Access Point Item Description Default Enable Click the toggle button to enable/disable the Wi-Fi access point option. Band Choose from “2.4G” or “5G”.
  • Page 56
    Robustel GoRugged R3000 User Guide General Settings @ Access Point Item Description Default Broadcast SSID Click the toggle button to enable/disable the SSID being broadcast. When enabled, the client can scan your SSID. When disabled, the client cannot scan your SSID. If you want to connect to the router AP, you need to manually enter the SSID of router AP at Wi-Fi client side.
  • Page 57
    Robustel GoRugged R3000 User Guide Click to add a MAC address to the Access Control List. The maximum count for MAC address is 64. Item Description Default General Settings Enable ACL Click the toggle button to enable ACL (Access Control List) option.
  • Page 58
    Robustel GoRugged R3000 User Guide Wi-Fi Client Configure R3000 as Wi-Fi client Click Interface > Wi-Fi > Wi-Fi, select “Client” as the mode and click “Submit”. And then a “WLAN” column will appear under the Interface list. Click Interface > Link Manager > Link Settings, and click the edit button of WLAN, then configure the related parameters of WLAN.
  • Page 59: Interface > Usb

    Robustel GoRugged R3000 User Guide This window allows you to scan for all the available SSIDs in your area and click one of those shown on the “Scan Results” list. 3.11 Interface > USB This section allows you to set the USB parameters. The USB interface of R3000 Router can be used for firmware upgrade and configuration upgrade.

  • Page 60: Interface > Di/Do

    Robustel GoRugged R3000 User Guide R3000 has the key for USB automatic update. User can generate the key in this page. Item Description Default USB Automatic Update Click to generate a key, and click to download the key. 3.12 Interface > DI/DO This section allows you to set the DI/DO parameters.

  • Page 61
    Robustel GoRugged R3000 User Guide The window is displayed as below when choosing “Counter” as the mode. General Settings @ DI Item Description Default Index Indicate the ordinal of the list. Enable Click the toggle button to enable/disable this DI.
  • Page 62
    Robustel GoRugged R3000 User Guide Click to enter the DO configuration window. The window is displayed as below when choosing “Pulse” as the alarm on action. RT_UG_R3000_v.4.0.0 27 March, 2017 61/136 Confidential…
  • Page 63
    Robustel GoRugged R3000 User Guide The window is displayed as below when choosing “Pulse” as the alarm off action. Item Description Default Index Indicate the ordinal of the list. Enable Click the toggle button to enable/disable this DO. Alarm On Action Digital Output initiates when there is an alarm. Selected from “High”, “Low” or High “Pulse”.
  • Page 64: Interface > Serial Port

    Robustel GoRugged R3000 User Guide Item Description Default square wave as specified in the pulse mode parameters. The low level widths are specified here. Enter from 1 to 30000 ms. High-level Set the high-level width. It is available when enabling Pulse as “Alarm On Width Action/Alarm Off Action”.

  • Page 65
    Robustel GoRugged R3000 User Guide Click the edit button of COM1. Serial Port Item Description Default Serial Port Application Settings Index Indicate the ordinal of the list. Port Show the current serial’s name, read only. Enable Click the toggle button to enable/disable this serial port. When the status is OFF, the serial port is not available.
  • Page 66
    Robustel GoRugged R3000 User Guide  The window is displayed as below when choosing “Transparent” as the application mode and “TCP Client” as the protocol. The window is displayed as below when choosing “Transparent” as the application mode and “TCP Server” as the protocol.
  • Page 67
    UDP: Router works as UDP client  Robustlink: Router will automatically upload the serial data to Robustlink platform under the Robustlink protocol. Robustlink is a management platform from Robustel. This function only available when Router is connects to Robustlink RT_UG_R3000_v.4.0.0…
  • Page 68: Network > Route

    Robustel GoRugged R3000 User Guide Server Settings Item Description Default Server Address Enter the address of server which will receive the data sent from Null router’s serial port. IP address or domain name will be available. Server Port Enter the specified port of server which is used for receiving the Null serial data.

  • Page 69: Network > Firewall

    Robustel GoRugged R3000 User Guide Static Route Item Description Default Index Indicate the ordinal of the list. Description Enter a description for this route. Null Destination Enter the IP address of destination host or destination network. Null Netmask Enter the Netmask of destination host or destination network.

  • Page 70
    Robustel GoRugged R3000 User Guide Filtering Item Description Default General Settings Enable Filtering Click the toggle button to enable/disable the filtering option. Default Filtering Policy Select from “Accept” or “Drop”. Cannot be changed when filtering Accept rules table is not empty.
  • Page 71: Port Mapping

    Robustel GoRugged R3000 User Guide Click to add filtering rule. The maximum count is 20. Filtering Rules Item Description Default Index Indicate the ordinal of the list. Description Enter a description for this filtering rule. Null Source Address Defines if access is allowed from one or a range of IP addresses which are defined Null by Source IP Address, or every IP addresses.

  • Page 72
    Robustel GoRugged R3000 User Guide Click to add port mapping rules. The maximum rule count is 40. Port Mapping Rules Item Description Default Index Indicate the ordinal of the list. Description Enter a description for this port mapping. Null Remote IP Specify the host or network which can access to the local IP address.
  • Page 73: Network > Ip Passthrough

    Robustel GoRugged R3000 User Guide 3.16 Network > IP Passthrough Click Network > IP Passthrough > IP Passthrough to enable or disable the IP Pass-through option. If router enables the IP Pass-through, the terminal device (such as PC) will enable the DHCP Client mode and connect to LAN port of the router;…

  • Page 74
    Robustel GoRugged R3000 User Guide Click to add tunnel settings. The maximum count is 3. Tunnel Settings Item Description Default Index Indicate the ordinal of the list. Enable Click the toggle button to enable/disable this IPsec tunnel. Description Enter a description for this IPsec tunnel.
  • Page 75
    Robustel GoRugged R3000 User Guide The window is displayed as below when choosing “PSK” as the authentication type. The window is displayed as below when choosing “CA” as the authentication type. The window is displayed as below when choosing “xAuth PSK” as the authentication type.
  • Page 76
    Robustel GoRugged R3000 User Guide The window is displayed as below when choosing “xAuth CA” as the authentication type. IKE Settings Item Description Default Negotiation Mode Select from “Main” and “Aggressive” for the IKE negotiation mode in phase 1. Main If the IP address of one end of an IPsec tunnel is obtained dynamically, the IKE negotiation mode must be aggressive.
  • Page 77
    Robustel GoRugged R3000 User Guide IKE Settings Item Description Default Remote ID Type Select from “Default”, “FQDN” and “User FQDN” for IKE negotiation. Default  Default: Uses an IP address as the ID in IKE negotiation  FQDN: Uses an FQDN type as the ID in IKE negotiation. If this option is selected, type a name without any at sign (@) for the local security gateway, e.g., test.robustel.com.
  • Page 78
    Robustel GoRugged R3000 User Guide SA Settings Item Description Default Encrypt Algorithm Select from “3DES”, “AES128” or “AES256” when you select “ESP” in 3DES “Protocol”. Higher security means more complex implementation and lower speed. DES is enough to meet general requirements. Use 3DES when high confidentiality and security are required.
  • Page 79
    Robustel GoRugged R3000 User Guide Status This section allows you to view the status of the IPsec tunnel. x509 User can upload the X509 certificates for the IPsec tunnel in this section. x509 Item Description Default X509 Settings Tunnel Name Choose a valid tunnel.
  • Page 80: Vpn > Openvpn

    Robustel GoRugged R3000 User Guide 3.18 VPN > OpenVPN This section allows you to set the OpenVPN and the related parameters. OpenVPN is an open-source software application that implements virtual private network (VPN) techniques for creating secure point-to-point or site-to-site connections in routed or bridged configurations and remote access facilities R3000 Router supports point-to-point and point-to-points connections.

  • Page 81
    Robustel GoRugged R3000 User Guide The window is displayed as below when choosing “Preshared” as the authentication type. RT_UG_R3000_v.4.0.0 27 March, 2017 80/136 Confidential…
  • Page 82
    Robustel GoRugged R3000 User Guide The window is displayed as below when choosing “Password” as the authentication type. RT_UG_R3000_v.4.0.0 27 March, 2017 81/136 Confidential…
  • Page 83
    Robustel GoRugged R3000 User Guide The window is displayed as below when choosing “X509CA” as the authentication type. RT_UG_R3000_v.4.0.0 27 March, 2017 82/136 Confidential…
  • Page 84
    Robustel GoRugged R3000 User Guide The window is displayed as below when choosing “X509CA Password” as the authentication type. General Settings @ OpenVPN Item Description Default Index Indicate the ordinal of the list. Enable Click the toggle button to enable/disable this OpenVPN tunnel.
  • Page 85
    Robustel GoRugged R3000 User Guide General Settings @ OpenVPN Item Description Default Authentication Type Select from “None”, “Preshared”, “Password”, “X509CA” and “X509CA None Password”. “None” and “Preshared” authentication type are only working with p2p mode. Username Enter the username used for “Password” or “X509CA Password”…
  • Page 86
    Robustel GoRugged R3000 User Guide Advanced Settings @ OpenVPN Item Description Default Enable HMAC Firewall Click the toggle button to enable/disable this option. Add an additional layer of HMAC authentication on top of the TLS control channel to protect against DoS attacks.
  • Page 87: Vpn > Gre

    Robustel GoRugged R3000 User Guide @crl.pem Certificate Files Index Indicate the ordinal of the list. Filename Show the imported certificate’s name. Null File Size Show the size of the certificate file. Null Last Modification Show the timestamp of that the last time to modify the certificate file.

  • Page 88: Services > Syslog

    Robustel GoRugged R3000 User Guide Local Virtual IP Address Set the local virtual IP address of the GRE tunnel. Null Local Virtual Netmask Set the local virtual Netmask of the GRE tunnel. Null Remote Virtual IP Address Set the remote virtual IP Address of the GRE tunnel.

  • Page 89: Services > Event

    Robustel GoRugged R3000 User Guide Syslog Settings Item Description Default Enable Click the toggle button to enable/disable the Syslog settings option. Syslog Level Select from “Debug”, “Info”, “Notice”, “Warning” or “Error”, which from low to Notice high. The lower level will output more syslog in detail.

  • Page 90
    Robustel GoRugged R3000 User Guide Click button to add an Event parameters. RT_UG_R3000_v.4.0.0 27 March, 2017 89/136 Confidential…
  • Page 91
    Robustel GoRugged R3000 User Guide General Settings @ Notification Item Description Default Index Indicate the ordinal of the list. Description Enter a description for this group. Null Sent SMS Click the toggle button to enable/disable this option. When enabled, the router will send notification to the specified phone numbers via SMS if event occurs.
  • Page 92: Services > Ntp

    Robustel GoRugged R3000 User Guide Event Details Item Description Default Save Position Select the events’ save position from “RAM” or “NVM”.  RAM: Random-access memory  NVM: Non-Volatile Memory Filter Message Event will be filtered according to the Filter Message that the user set. Click the Null “Refresh”…

  • Page 93: Services > Sms

    Robustel GoRugged R3000 User Guide NTP Server Settings Enable Click the toggle button to enable the NTP server option. This window allows you to view the current time of router and also synchronize the router time. Click button to synchronize the router time with PC’s.

  • Page 94: Services > Email

    Robustel GoRugged R3000 User Guide User can test the current SMS service whether it is available in this section. SMS Testing Item Description Default Phone Number Enter the specified phone number which can receive the SMS from router. Null Message Enter the message that router will send it to the specified phone number.

  • Page 95: Services > Ddns

    Robustel GoRugged R3000 User Guide Email Settings Item Description Default Outgoing server Enter the SMTP server IP Address or domain name. Null Server port Enter the SMTP server port. Timeout Set the max time for sending email to SMTP server. When the server doesn’t receive the email over this time, it will try to resend.

  • Page 96: Services > Ssh

    Robustel GoRugged R3000 User Guide Hostname Enter the hostname provided by the DDNS server. Null Username Enter the username provided by the DDNS server. Null Password Enter the password provided by the DDNS server. Null Enter the URL customized by user.

  • Page 97: Services > Gps

    Robustel GoRugged R3000 User Guide Keys Management Item Description Authorized Keys Click on “Choose File” to locate an authorized key from your computer, and then click “Import” to import this key into your router. Note: This option is valid when enabling the password logins option.

  • Page 98
    Robustel GoRugged R3000 User Guide The window is displayed as below when choosing “TCP Server” as the protocol. The window is displayed as below when choosing “UDP” as the protocol. Server Settings Item Description Default Index Indicate the ordinal of the list.
  • Page 99
    Robustel GoRugged R3000 User Guide Server Settings Item Description Default Server Address @ UDP Set the address of the TCP Server. Null Server Port @ UDP Set the port of the remote TCP Server. Null Send GGA Sentence Send GGA information in NMEA format.
  • Page 100: Services > Web Server

    Robustel GoRugged R3000 User Guide 3.28 Services > Web Server This section allows you to modify the parameters of Web Server. Basic @ Web Server Item Description Default HTTP Port Enter the HTTP port number you want to change in router’s Web Server. On a Web server, port 80 is the port that the server «listens to»…

  • Page 101: Services > Advanced

    Robustel GoRugged R3000 User Guide number except 443, only adding that port number then you can login R3000’s Web Server. Note: HTTPS is more secure than HTTP. In many cases, clients may be exchanging confidential information with a server, which needs to be secured in order to prevent unauthorized access.

  • Page 102
    Robustel GoRugged R3000 User Guide or “WiFi”.  None: Meaningless indication, and the LED is off  OpenVPN: USR indicator showing the OpenVPN status  IPsec: USR indicator showing the IPsec status  WiFi: USR indicator showing the Wi-Fi status Note: For more details about USR indicator, see “2.1 LED Indicators”.
  • Page 103: System > Debug

    Robustel GoRugged R3000 User Guide 3.30 System > Debug This section allows you to check and download the syslog details. Syslog Item Description Default Syslog Details Log Level Select from “Debug”, “Info”, “Notice”, “Warn”, “Error” which from low to high.

  • Page 104: System > Update

    Robustel GoRugged R3000 User Guide Click the button to refresh the syslog. Syslog Files Syslog Files List It can show at most 5 syslog files in the list, the files’ name range from message0 to message 4. And the newest syslog file will be placed on the top of the list.

  • Page 105
    Robustel GoRugged R3000 User Guide App Center Item Description Default App Install File Click on “Choose File” to locate the App file from your computer, and then click to import this file into your router. Note: File format should be xxx.rpk, e.g. R3000-robustlink-1.0.0.rpk.
  • Page 106: System > Tools

    Robustel GoRugged R3000 User Guide 3.33 System > Tools This section provides users three tools: Ping, Traceroute and Sniffer. Ping Item Description Default IP address Enter the ping’s destination IP address or destination domain. Null Number of Requests Specify the number of ping requests.

  • Page 107
    Robustel GoRugged R3000 User Guide Traceroute Item Description Default Trace Address Enter the trace’s destination IP address or destination domain. Null Trace Hops Specify the max trace hops. Router will stop tracing if the trace hops has met max value no matter the destination has been reached or not.
  • Page 108: System > Profile

    Robustel GoRugged R3000 User Guide Sniffer Item Description Default Interface Choose the interface according to your Ethernet configuration. Host Filter the packet that contain the specify IP address. Null Packets Request Set the packet number that the router can sniffer at a time.

  • Page 109: System > User Management

    Robustel GoRugged R3000 User Guide Ignore Invalid Settings Click the toggle button as “OFF” to ignore invalid settings. XML Configuration File Click on to locate the XML configuration file from your computer, and then click to import this file into your router.

  • Page 110
    Robustel GoRugged R3000 User Guide Super User Settings Item Description Default Old Username Enter the old username of your router. The default is “admin”. Null New Username Enter a new username you want to create; valid characters are a-z, A-Z, 0-9, Null @, ., -, #, $, and *.
  • Page 111: Chapter 4 Configuration Examples

    Robustel GoRugged R3000 User Guide Chapter 4 Configuration Examples 4.1 Interface 4.1.1 Console Port You can use the console port to manage the router via CLI commands, please refer to Chapter 5 Introductions for CLI. 4.1.2 Digital Input R3000 supports digital input with dry contact.

  • Page 112: Digital Output

    Robustel GoRugged R3000 User Guide 4.1.3 Digital Output R3000 supports digital output with wet contact. Please refer to the right side figure to connect the negative pole of the power to the port marked “GND”. External The maximum output voltage, output…

  • Page 113: Cellular

    Robustel GoRugged R3000 User Guide 4.1.5 RS-485 R3000 supports one RS-485 for serial data communication. Please refer to the connection diagram at the right side. 4.2 Cellular 4.2.1 Cellular Dial-Up This section shows you how to configure the primary and backup SIM card for Cellular Dial-up. Connect the router correctly and insert two SIM, then open the configuration page.

  • Page 114
    Robustel GoRugged R3000 User Guide Click the edit button of WWAN1 to set its parameters according to the current ISP. When finished, click Submit > Save & Apply for the configuration to take effect. RT_UG_R3000_v.4.0.0 27 March, 2017 113/136 Confidential…
  • Page 115: Sms Remote Control

    Robustel GoRugged R3000 User Guide The window is displayed below by clicking Interface > Cellular > Advanced Cellular Settings. Click the edit button of SIM1 to set its parameters according to your application request. When finished, click Submit > Save & Apply for the configuration to take effect.

  • Page 116
    Robustel GoRugged R3000 User Guide please refer to Chapter 5 Introductions for CLI. Note: Download the configure XML file from the configured web browser. The format of SMS control command can refer to the data of the XML file. Go to System > Profile > Export Configuration File, click to generate the XML file and click to export the XML file.
  • Page 117: Network

    Robustel GoRugged R3000 User Guide device_model = R3000 serial_number = 201612221052 uptime = «0 days, 00:39:31» system_time = «Mon Feb 27 09:52:52 2017» admin:admin;reboot In this command, username is “admin”, password is “admin”, and the command is to reboot the Router.

  • Page 118
    Robustel GoRugged R3000 User Guide The configuration of server and client is as follows. IPsec VPN_SERVER: Cisco 2811: RT_UG_R3000_v.4.0.0 27 March, 2017 117/136 Confidential…
  • Page 119
    Robustel GoRugged R3000 User Guide IPsec VPN_CLIENT: The window is displayed as below by clicking VPN > IPsec > Tunnel. Click button and set the parameters of IPsec Client as below. RT_UG_R3000_v.4.0.0 27 March, 2017 118/136 Confidential…
  • Page 120
    Robustel GoRugged R3000 User Guide When finished, click Submit > Save & Apply for the configuration to take effect. The comparison between server and client is as below. RT_UG_R3000_v.4.0.0 27 March, 2017 119/136 Confidential…
  • Page 121: Openvpn

    Robustel GoRugged R3000 User Guide 4.3.2 OpenVPN OpenVPN supports two modes, including Client and P2P. Here takes P2P as an example. The configuration of two points is as follows. OPENVPN (P2P): Point 1 The window is displayed as below by clicking VPN > OpenVPN > OpenVPN.

  • Page 122
    Robustel GoRugged R3000 User Guide Click button and set the parameters of point1 as below. When finished, click Submit > Save & Apply for the configuration to take effect. RT_UG_R3000_v.4.0.0 27 March, 2017 121/136 Confidential…
  • Page 123
    Robustel GoRugged R3000 User Guide Point 2 Click button and set the parameters of point2 as below. When finished, click Submit > Save & Apply for the configuration to take effect. RT_UG_R3000_v.4.0.0 27 March, 2017 122/136 Confidential…
  • Page 124: Gre Vpn

    Robustel GoRugged R3000 User Guide The comparison between point 1 and point 2 is as below. 4.3.3 GRE VPN The configuration of two points is as follows. The window is displayed as below by clicking VPN > GRE > GRE.

  • Page 125
    Robustel GoRugged R3000 User Guide GRE-1 : Click button and set the parameters of GRE-1 as below. When finished, click Submit > Save & Apply for the configuration to take effect. GRE-2: Click button and set the parameters of GRE-1 as below.
  • Page 126
    Robustel GoRugged R3000 User Guide The comparison between GRE-1 and GRE-2 is as below. RT_UG_R3000_v.4.0.0 27 March, 2017 125/136 Confidential…
  • Page 127: Chapter 5 Introductions For Cli

    Robustel GoRugged R3000 User Guide Chapter 5 Introductions for CLI 5.1 What Is CLI The R3000 command-line interface (CLI) is a software interface providing another way to set the parameters of equipment from the SSH or through a telnet network connection.

  • Page 128: How To Configure The Cli

    Robustel GoRugged R3000 User Guide 5.2 How to Configure the CLI Following is a table about the description of help and the error should be encountered in the configuring program. Commands /tips Description Typing a question mark “?” will show you the help information.

  • Page 129
    Robustel GoRugged R3000 User Guide Flashing Checking 100% Decrypting 100% Flashing 100% Verifying 100% Verfify Success upgrade success //update success # config save_and_apply // save and apply current configuration, make you configuration effect Example 3: Set link-manager # set # set…
  • Page 130
    Robustel GoRugged R3000 User Guide # set link_manager primary_link wwan1 //select “wwan1” as primary_link //setting succeed # set link_manager link 1 type Type desc Description connection_type Connection Type wwan WWAN Settings static_addr Static Address Settings pppoe PPPoE Settings ping Ping Settings…
  • Page 131
    Robustel GoRugged R3000 User Guide mtu = 1500 dhcp { enable = true mode = server relay_server = «» pool_start = 192.168.0.2 pool_end = 192.168.0.100 netmask = 255.255.255.0 gateway = «» primary_dns = «» secondary_dns = «» wins_server = «»…
  • Page 132
    Robustel GoRugged R3000 User Guide Example 5: CLI for setting Cellular # show cellular all sim { id = 1 card = sim1 phone_number = «» extra_at_cmd = «» network_type = auto band_select_type = all band_gsm_850 = false band_gsm_900 = false…
  • Page 133
    Robustel GoRugged R3000 User Guide band_wcdma_1900 = false band_wcdma_2100 = false band_lte_800 = false band_lte_850 = false band_lte_900 = false band_lte_1800 = false band_lte_1900 = false band_lte_2100 = false band_lte_2600 = false band_lte_1700 = false band_lte_700 = false band_tdd_lte_2600 = false…
  • Page 134: Commands Reference

    Robustel GoRugged R3000 User Guide band_lte_1900 LTE 1900 (band 2) band_lte_2100 LTE 2100 (band 1) band_lte_2600 LTE 2600 (band 7) band_lte_1700 LTE 1700 (band 4) band_lte_700 LTE 700 (band 17) band_tdd_lte_2600 TDD LTE 2600 (band 38) band_tdd_lte_1900 TDD LTE 1900 (band 39)

  • Page 135: Glossary

    Robustel GoRugged R3000 User Guide Glossary Abbr. Description Alternating Current Access Point Name ASCII American Standard Code for Information Interchange Conformité Européene (European Conformity) CHAP Challenge Handshake Authentication Protocol Command Line Interface for batch scripting Circuit Switched Data Clear to Send…

  • Page 136
    Robustel GoRugged R3000 User Guide Abbr. Description L2TP Layer 2 Tunneling Protocol local area network Light Emitting Diode Machine to Machine Maximum Minimum Mobile Originated Mobile Station Mobile Terminated OpenVPN Open Virtual Private Network Password Authentication Protocol Personal Computer Personal Communications Network, also referred to as DCS 1800…
  • Page 137
    Robustel GoRugged R3000 User Guide Abbr. Description Virtual Private Network VSWR Voltage Stationary Wave Ratio Wide Area Network RT_UG_R3000_v.4.0.0 27 March, 2017 136/136 Confidential…
  • Page 138
    Robustel GoRugged R3000 User Guide Guangzhou Robustel Technologies Co., Ltd Address: 3rd Floor, Building F, Kehui Park, No.95 Daguan Road, Guangzhou, China 510660 Tel: 086-20-29019902 Email: info@robustel.com RT_UG_R3000_v.4.0.0 27 March, 2017 137/136 Confidential…

Robustel R3000-3P

  • Описание
  • Характеристики
  • Загрузить
  • Протестировать
  • Купить

Robustel R3000-3P — промышленный 3G роутер с двумя SIM-картами для UMTS/HSPA сетей.

Возможен заказ моделей с поддержкой Wi-Fi 802.11 b/g/n, GPS.

В наличии есть SDK (комплект средств разработки). 

Надёжный 3G роутер R3000-3P предназначен для приёма/передачи данных по сотовым сетям в М2М системах.

Отличительные особенности

  • Поддержка HSPA+
  • Двойное резервирование SIM для непрерывной сотовой связи, поддерживает 3G
  • Метод антенного разделения (Antenna diversity) для улучшения производительности передачи
  • Два Ethernet порта, могут быть настроены как 2 LAN или 1 LAN – 1 WAN (поддерживает беспроводной WAN и резервирование по проводному WAN).
  • 1x RS232, 1x RS485, 1 консольный порт, 2 цифровых входа, 2 цифровых выхода, 1 высокоскоростной USB до 480 Мбит/с.
  • 6 индикаторов LED показывают статус в сети и интенсивность сигнала (RSSI).
  • Широкий диапазон входного напряжения — от 12 до 70 В, и рабочих температур -40°С…+70°С.
  • Металлический корпус с возможностью крепления на DIN-рейку или к стене, также с дополнительным заземлением.
  • Сетевые протоколы PPP, PPPoE, TCP, UDP, DHCP, ICMP, NAT, DMZ, RIP, OSPF, DDNS, VRRP, HTTP, HTTPs.
  • VPN туннелирование: IPSec/OpenVPN/PPTP/L2TP клиент/сервер, GRE.
  • Управление: Web, CLI, SNMP, SMS, М2М-платформа Robustlink.
  • Поддерживает Modbus/RTU в Modbus/TCP.
  • Всегда «on-line», «пробуждение» по SMS или в течение заданного времени суток.
  • Автоматическая перезагрузка с помощью SMS или в заданное время суток.
  • Удалённое конфигурирование по SMS.
  • Обновление ПО через Web-интерфейс.

Сферы применения

  • Банкоматы и вендинг
  • Системы солнечной и ветровой энергии
  • Автоматизация
  • Автоматическое считывание показаний измерительных приборов
  • Промышленная автоматизация
  • IP видео наблюдение
  • Управление удалёнными устройствами.
Параметр Значение
Частотный диапазон, МГц GSM/GPRS/EDGE/UMTS/HSPA
GPRS/EDGE: 850/900/1800/1900 МГц

HSPA+: 850/900/1900/2100 или 900/2100 или 850/1900 МГц опционально,
DL/UL 14.4/5.76 Мбит/с, переключение на 2G

Интерфейсы  2 SIM
2 Ethernet: 2 x 10/100 Мбит/с, 2 LAN или 1 LAN 1 WAN
RS-232, RS-485
2 цифровых входа
2 цифровых выхода
6 индикаторов LED
USB
Антенный интерфейс SMA (f)
Сторожевой таймер (Watchdog) и
часы реального времени (RTC)
Да 
Входное напряжение, В 12…70  
Энергопотребление режим покоя: 100 мА @ 12 В
режим передачи данных: 500 … 1000 мА (в пике) @ 12 В
Дипазон рабочих температур  -40°С…+70°C 
Размеры, мм  125 x 108 x 45 
Вес, г  500
Гарантия  1 год 

Robustel GoRugged R3000 User Guide

Enable

This window allows you to view the current time of router and also synchronize the router time. Click

to synchronize the router time with PC’s.

3.23 Services > SMS

This section allows you to set SMS parameters. R3000 Router supports SMS management. User can control and

configure their routers by sending SMS. For more details about SMS control, refer to 4.2.2 SMS Remote Control.

Item

Enable

Authentication Type

Phone Number

RT_UG_R3000_v.4.0.0

Confidential

Click the toggle button to enable the NTP server option.

Description

Click the toggle button to enable/disable the SMS Management option.

Note: If this option is disabled, the SMS configuration is invalid.

Select Authentication Type from «Password», «Phonenum» or «Both».

Password: Use the same username and password as WEB manager for

authentication. For example, the format of the SMS should be «username:

password; cmd1; cmd2; …»

Note: Set the WEB manager password in System > User Management

section.

Phonenum: Use the Phone number for authenticating, and user should set

the Phone Number that is allowed for SMS management. The format of

the SMS should be «cmd1; cmd2; …»

Both: Use both the «Password» and «Phonenum» for authentication. User

should set the Phone Number that is allowed for SMS management. The

format of the SMS should be «username: password; cmd1; cmd2; …»

Set the phone number used for SMS management, and use ‘; ‘to separate each

number.

NTP Server Settings

SMS

27 March, 2017

OFF

button

Default

ON

Password

Null

92/136

Robustel R3000-3P — производительное и универсальное решение для промышленного использования, гарантирующее безопасное проводное, WiFi и мобильное соединение даже в самых неблагоприятных условиях. Роутер подойдет для работы в системах межмашинного взаимодействия (M2M) и интернета вещей (IoT), не требующих высокоскоростного подключения для обмена данными. Благодаря маршрутизатору от Robustel, вы сможете связать воедино промышленные датчики, телеметрические устройства, торговые терминалы, IP-камеры, оборудование и приборы дистанционного контроля. Для передачи данных за пределы сети вашего предприятия используется подключение GSM или 3G.

К устройству подсоединяются две антенны для работы с мобильными сетями и одна антенна для функционирования WiFi-модуля. Корпус имеет два разъема для SIM-карт, а также два Ethernet-порта, которые могут быть настроены как LAN-порты или как один LAN- и один WAN-порт. Роутер поддерживает стандарты WiFi 802.11a/b/g/n с максимальной скоростью передачи данных до 150 Мбит/с. На базе R3000-L3H можно создать проводную локальную сеть с подключением к интернету не только по каналам сотовой связи, но и по WAN-интерфейсу.

Интерфейсы RS-232 и RS-485 пригодятся для подключения разнообразного промышленного оборудования; также в распоряжении пользователя имеются дополнительные цифровые входы и выходы. USB-порт используется для загрузки конфигурационного файла и обновления прошивки роутера. Базовую информацию о работе мобильных сетей и каналов связи можно получить, благодаря встроенным световым индикаторам. Устройство функционирует на собственной операционной системе RobustOS. Вспомогательный инструментарий (SDK) может быть полезен в условиях самостоятельной разработки на языках программирования C, Python или Java. Питание осуществляется через клеммные колодки в нижней части устройства.

Работа с роутером и настройка параметров производятся через веб-интерфейс, SMS, командную строку или платформу RobustLink Cloud. Маршрутизатор поддерживает наиболее востребованные интернет-протоколы: PPP, PPPoE, TCP, UDP, DHCP, ICMP, NAT, HTTP, HTTPs, DNS, ARP, NTP, SMTP, Telnet, VLAN, SSH2, DDNS и др. Отдельно можно настроить брандмауэр, организовать фильтрацию трафика, защиту от DoS-атак, подключить IPsec, OpenVPN и многое другое.

Роутер Robustel R3000-3P — буклет [PDF, ~700Kb]

Роутер Robustel R3000-3P — быстрая настройка [PDF, ~1.6Mb]

Роутер Robustel R3000-3P — руководство пользователя [PDF, ~7.2Mb]

Характеристики
Стандарты сотовой связи GSM/GPRS/EDGE/HSDPA/HSUPA/HSPA+
Частотные диапазоны 2G: 850/900/1800/1900 МГц
3G: 800/850/900/1700/1900/2100 МГц
Максимальная скорость передачи данных (3G) 14,4 Мбит/с (DL) / 5,76 Мбит/с (UL)
Порты и разъемы 2 x SMA-female
1 x RP-SMA-female
2 x Ethernet
1 x USB
1 x MicroSD
2 x SIM
1 x 3-пиновый разъем питания
Дополнительные интерфейсы 1 x RS-232
1 x RS-485
2 x DI («сухой» контакт)
2 x DO («мокрый» контакт)
Ethernet 10/100 Мбит/с
Скорость последовательных интерфейсов от 300 до 230400 бит/с
Операционная система RobustOS
Сетевые протоколы PPP, PPPoE, TCP, UDP, DHCP, ICMP, NAT, HTTP, HTTPs, DNS, ARP, NTP, SMTP, Telnet, VLAN, SSH2, DDNS и др.
Безопасность DMZ, защита от DoS-атак, фильтрация (по IP, MAC, имени домена), зеркалирование портов, контроль доступа и др.
Питание 9–60В
Энергопотребление 100 мА при напряжении 12В в простое;
до 400 мА при напряжении 12В при передаче данных
Защита корпуса IP30
Крепление возможен монтаж на DIN-рейку при помощи дополнительного крепежа
Рабочая температура от -40°С до +75°С
Допустимая влажность от 5% до 95%
Размер 125 x 104 x 43.5 мм
Вес 570 г
Комплектация роутер, клеммники, инструкция по быстрой настройке

Robustel R3000-3P — промышленный 3G роутер с двумя SIM-картами для UMTS/HSPA сетей.

Надёжный 3G роутер R3000-3P предназначен для приёма/передачи данных по сотовым сетям в М2М системах.

Отличительные особенности
Поддержка HSPA+
Двойное резервирование SIM для непрерывной сотовой связи, поддерживает 3G
Метод антенного разделения (Antenna diversity) для улучшения производительности передачи
Два Ethernet порта, могут быть настроены как 2 LAN или 1 LAN – 1 WAN (поддерживает беспроводной WAN и резервирование по проводному WAN).
1x RS232, 1x RS485, 1 консольный порт, 2 цифровых входа, 2 цифровых выхода, 1 высокоскоростной USB до 480 Мбит/с.
6 индикаторов LED показывают статус в сети и интенсивность сигнала (RSSI).
Широкий диапазон входного напряжения — от 12 до 70 В, и рабочих температур -40°С…+70°С.
Металлический корпус с возможностью крепления на DIN-рейку или к стене, также с дополнительным заземлением.
Сетевые протоколы PPP, PPPoE, TCP, UDP, DHCP, ICMP, NAT, DMZ, RIP, OSPF, DDNS, VRRP, HTTP, HTTPs.
VPN туннелирование: IPSec/OpenVPN/PPTP/L2TP клиент/сервер, GRE, DMVPN.
Управление по Web, CLI, SNMP, SMS.
Поддерживает Modbus/RTU в Modbus/TCP.
Всегда «on-line», «пробуждение» по SMS или в течение заданного времени суток.
Автоматическая перезагрузка с помощью SMS или в заданное время суток.
Удалённое конфигурирование по SMS.
Обновление ПО через Web-интерфейс.

Сферы применения
Банкоматы и вендинг
Системы солнечной и ветровой энергии
Автоматизация
Автоматическое считывание показаний измерительных приборов
Промышленная автоматизация
IP видео наблюдение
Управление удалёнными устройствами.

Частотный диапазон, МГц GSM/GPRS/EDGE/UMTS/HSPA/FDD LTE
GPRS/EDGE: 850/900/1800/1900 МГц
HSUPA: 900/2100 или 850/1900 МГц опционально,
DL/UL 7.2/5.76 Мбит/с, переключение на 2G
HSPA+: 850/900/1900/2100 или 900/2100 или 850/1900 МГц опционально,
DL/UL 14.4/5.76 Мбит/с, переключение на 2G
FDD LTE: 800/900/1800/2100/2600 МГц или 700 МГц (B17 или B13) опционально,
DL/UL до 100/50 Мбит/с, переключение на 3G/2G
Интерфейсы 2 SIM
2 Ethernet: 2 x 10/100 Мбит/с, 2 LAN или 1 LAN 1 WAN
RS-232, RS-485
2 цифровых входа
2 цифровых выхода
6 индикаторов LED
USB
Антенный интерфейс SMA (f)
Сторожевой таймер (Watchdog) и часы реального времени (RTC) Да
Входное напряжение, В 12…70
Энергопотребление режим покоя: 100 мА @ 12 В
режим передачи данных: 500 … 1000 мА (в пике) @ 12 В
Диапазон рабочих температур -40°С…+70°C
Размеры, мм 125 x 108 x 45
Вес, г 500

Понравилась статья? Поделить с друзьями:
  • Руководство по эксплуатации по ак 74м
  • Димексид инструкция по применению компресс при шпоре
  • Эхинацин инструкция по применению взрослым ликвидум
  • Оскорбление руководства страны
  • Практическая электроника иллюстрированное руководство для радиолюбителей монк с 2020