    ___________________ Preface ___________________ Documentation guide Memory areas and retentive ___________________ SIMATIC memory ___________________ Memory usage and application examples S7-1500, ET 200SP, ET 200pro Structure and Use of the CPU ___________________ Memory SIMATIC memory card Function Manual 10/2018 A5E03461664-AC…
  • Page 3
    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Preface

    Scope of the documentation This documentation is valid for the central modules of the S7-1500 and ET 200SP systems and for the ET 200pro CPU 1516pro-2 PN. The CPUs of the redundant system S7-1500R/H do not support all the memory objects described in this function manual.

  • Page 5
    Functions that you will be familiar with Manual CPU 1510SP-1 PN • contents ual expanded to include the from the SIMATIC S7-1500 CPUs are (https://support.industry.sie CPUs of the ET 200SP implemented in CPUs in other designs mens.com/cs/ww/en/view/9 distributed I/O system and…
  • Page 6
    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers’ exposure to cyber threats.
  • Page 7
    This information is provided by the Siemens Industry Online Support in the Internet (https://support.industry.siemens.com). Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP).
  • Page 8: Table Of Contents

    Table of contents Preface …………………………3 Documentation guide ……………………..8 Memory areas and retentive memory ………………..13 Memory areas ……………………. 13 2.1.1 Specifics of the CPUs of the redundant system S7-1500R/H ……….16 Memory requirements and memory usage …………….18 Retentive memory areas ………………….

  • Page 9: Documentation Guide

    Documentation guide The documentation for the SIMATIC S7-1500 automation system, for CPU 1516pro-2 PN based on SIMATIC S7-1500, and for the distributed I/O systems SIMATIC ET 200MP, ET 200SP and ET 200AL is divided into three areas. This division allows you easier access to the specific information you require.

  • Page 10
    You must register once to use the full functionality of «mySupport». You can find «mySupport» on the Internet (https://support.industry.siemens.com/My/ww/en). «mySupport» — Documentation In the Documentation area in «mySupport» you can combine entire manuals or only parts of these to your own manual.
  • Page 11
    ● Manuals, characteristics, operating manuals, certificates ● Product master data You can find «mySupport» — CAx data on the Internet (https://support.industry.siemens.com/my/ww/en/CAxOnline). Application examples The application examples support you with various tools and examples for solving your automation tasks. Solutions are shown in interplay with multiple components in the system — separated from the focus on individual products.
  • Page 12
    You can find the SIMATIC Automation Tool on the Internet (https://support.industry.siemens.com/cs/ww/en/view/98161300). PRONETA With SIEMENS PRONETA (PROFINET network analysis), you analyze the plant network during commissioning. PRONETA features two core functions: ● The topology overview independently scans PROFINET and all connected components.
  • Page 13
    Documentation guide SINETPLAN SINETPLAN, the Siemens Network Planner, supports you in planning automation systems and networks based on PROFINET. The tool facilitates professional and predictive dimensioning of your PROFINET installation as early as in the planning stage. In addition, SINETPLAN supports you during network optimization and helps you to exploit network resources optimally and to plan reserves.
  • Page 14: Memory Areas And Retentive Memory

    Memory areas and retentive memory Memory areas The automation data is located in the automation system in different memory areas. The offline data of the project created in STEP 7 is located on the hard disk of the programming device. The online data of the project is located in the load memory on the SIMATIC memory card.

  • Page 15: The Simatic Memory Card

    For additional information on the CPUs, refer to the CPU 1518-4 PN/DP MFP (https://support.industry.siemens.com/cs/ww/en/view/109749061) manual and the CPU 1518(F)-4 PN/DP MFP (https://support.industry.siemens.com/cs/ww/en/view/109756478) product information. You can find information on creating C/C++ runtime applications in the SIMATIC S7-1500 ODK 1500S (https://support.industry.siemens.com/cs/ww/en/view/109752683) manual. Structure and Use of the CPU Memory Function Manual, 10/2018, A5E03461664-AC…

  • Page 16
    Retentive behavior of the memory objects (Page 30). You can find additional information on the memory reset and reset to factory settings functions in the following manuals: ● System manual S7-1500, ET 200MP Automation System (http://support.automation.siemens.com/WW/view/en/59191792) ● System manual ET 200SP Distributed I/O System (http://support.automation.siemens.com/WW/view/en/58649293)
  • Page 17: Specifics Of The Cpus Of The Redundant System S7-1500R/H

    Memory areas and retentive memory 2.1 Memory areas Additional memory areas Besides the memory areas that have been described for the user program and data, the CPU has additional memory areas available. The additional memory areas include the following: ● Process images ●…

  • Page 18
    CPUs. For additional information on redundancy IDs of the CPUs, refer to the Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833) system manual. You can find an overview of the retentive behavior of the individual memory objects in section Retentive behavior of the memory objects (Page 30).
  • Page 19: Memory Requirements And Memory Usage

    You can access information regarding the memory areas of the CPUs in the following ways depending on product family used: Product family Information regarding the memory areas of the CPU is accessible via: STEP 7 Web server Display S7-1500 ✓ ✓ ✓ S7-1500R/H ✓ ✓…

  • Page 20
    Memory areas and retentive memory 2.2 Memory requirements and memory usage Memory requirements of the program in the offline project During creation or modification of a project, the display of memory utilization in STEP 7 shows you the size of the project in the following memories: ●…
  • Page 21
    Therefore, the drop-down list with the size of your SIMATIC memory card only serves as a visual orientation aid. Also refer to the FAQ «How do you estimate the memory requirements of your project in the load memory of a SIMATIC S7-1500» on the Internet (https://support.industry.siemens.com/cs/ww/en/view/97553417). Note Display of the memory utilization under «Program info»…
  • Page 22
    Memory areas and retentive memory 2.2 Memory requirements and memory usage Data on the SIMATIC memory card In addition to the program and the associated program elements (blocks, data types, objects for motion control and PLC tags), the following data is also stored on the memory card: ●…
  • Page 23
    Memory areas and retentive memory 2.2 Memory requirements and memory usage Display of the memory utilization in STEP 7 In online mode, the online function «Memory» provides you with the following up-to-date memory information: ● Size of the total free and already allocated load memory on the SIMATIC memory card. ●…
  • Page 24
    Memory areas and retentive memory 2.2 Memory requirements and memory usage Display of the memory utilization on the display of the CPU To obtain information about the available memory via the display, proceed as follows: ● Select the «Diagnostics» menu on the display with the help of the arrow keys. ●…
  • Page 25
    Memory areas and retentive memory 2.2 Memory requirements and memory usage Note Display of the memory utilization of redundant system S7-1500R/H in non-redundant operation The CPU displays indicate the local memory utilization of the respective CPU. Display of the memory utilization of redundant system S7-1500R/H in redundant operation Irrespective of the sizes of the inserted SIMATIC memory cards, both CPU displays indicate the same (synchronized) fill level.
  • Page 26
    On the Web server, you can find information about the current usage of the individual memory areas on the Web page «Diagnostics» in the «Memory» tab. Detailed information about the use of the Web server can be found in the S7-1500 Web server (https://support.industry.siemens.com/cs/ww/en/view/59193560) function manual.
  • Page 27: Retentive Memory Areas

    Memory areas and retentive memory 2.3 Retentive memory areas Retentive memory areas Introduction The CPUs have a memory for storing retentive data at POWER OFF. You can find the size of the retentive memory in the technical specifications of the respective CPU. You can find the utilization of the retentive memory of the configured CPU in STEP 7 offline under «Program info >…

  • Page 28
    Figure 2-6 Retentivity setting «Optimized block access» not activated You can find additional information on optimized and non-optimized data blocks in the Programming guideline for S7-1200/S7-1500 (https://support.industry.siemens.com/cs/de/de/view/90885040/en). Tags of an instance data block of a function block You can define the tags of the instance data block of a function block as retentive in STEP 7.
  • Page 29
    Memory areas and retentive memory 2.3 Retentive memory areas Creation of a data block in the user program The instruction «CREATE_DB» is used to create a new data block in the load and/or work memory. For data blocks which you create in the load memory, depending on the selection for the ATTRIB parameter, the generated data block either has the property «retentive»…
  • Page 30
    Memory areas and retentive memory 2.3 Retentive memory areas Bit memories, timers and counters You can define the number of retentive bit memories, timers and counters in STEP 7 in the PLC tag table using the «Retain» button. Figure 2-7 Definition of the number of retentive bit memories, timers and counters (beginning at 0, continuing without gaps) using the «Retain»…
  • Page 31: Summary Of Retentive Behavior

    Memory areas and retentive memory 2.4 Summary of retentive behavior Summary of retentive behavior 2.4.1 Retentive behavior of the memory objects This section gives an overview of the retentive behavior of the memory objects of the CPUs. In addition to the retentive memory areas described, there are other objects with retentive characteristics, for example, the diagnostics buffer.

  • Page 32
    Reference You can find additional information on the memory reset and reset to factory settings functions in the following manuals: ● System manual S7-1500, ET 200MP Automation System (http://support.automation.siemens.com/WW/view/en/59191792) ● System manual ET 200SP Distributed I/O System (http://support.automation.siemens.com/WW/view/en/58649293) ●…
  • Page 33: Memory Behavior When Loading Software Changes

    Memory areas and retentive memory 2.5 Memory behavior when loading software changes Memory behavior when loading software changes Introduction You can download software changes in STOP and RUN without affecting the actual values of previously loaded tags. You load changes to the software in STEP 7 (in the project tree and with selected PLC station) under «Download to device >…

  • Page 34
    Memory areas and retentive memory 2.5 Memory behavior when loading software changes Impacts of software changes on data blocks without memory reserve If you are not using memory reserve, you can load the following software changes without this reinitializing the actual values of DB tags that have already been loaded: ●…
  • Page 35: Memory Requirements For Downloading Software Changes

    Memory areas and retentive memory 2.6 Memory requirements for downloading software changes Memory requirements for downloading software changes Memory requirements in RUN state For the consistent and atomic execution of the complete download operation, the CPU requires adequate free memory space in the work memory and on the SIMATIC memory card.

  • Page 36
    Memory areas and retentive memory 2.6 Memory requirements for downloading software changes Example: A STEP 7 program contains an organization block (OB), 20 functions (FC) and a data block (DB). The OB calls the 20 FCs. All the FCs access the DB. If you change the program code in one of the FCs, the following load procedure only contains the changed FC.
  • Page 37
    Memory areas and retentive memory 2.6 Memory requirements for downloading software changes To find the interdependencies of the individual objects, double-click «Program info» in the project tree. Change to the «Dependency structure» tab in the «Program info» dialog. Figure 2-9 Dependency structure Structure and Use of the CPU Memory Function Manual, 10/2018, A5E03461664-AC…
  • Page 38
    Internet (https://support.industry.siemens.com/cs/ww/en/view/107108015). ● «Why can you not load the project data into the load memory of the S7-1500 CPU when the number of alarms and messages is too large?» on the Internet (https://support.industry.siemens.com/cs/ww/en/view/109751485).
  • Page 39: Memory Usage And Application Examples

    Memory usage and application examples Memory usage for recipes Introduction A recipe is a collection of parameter sets with the same structure. These recipe data records are located in a non-runtime-relevant data block in the load memory, and do not occupy any storage space in the work memory.

  • Page 40
    Figure 3-1 Processing sequence with «READ_DBL» and «WRIT_DBL» Also note the FAQ «How do you configure data blocks with the «Only store in load memory» attribute for the S7-1200/S7-1500? » in the Internet (https://support.industry.siemens.com/cs/ww/en/view/53034113). Note Instructions that access the SIMATIC memory card have a lower performance than instructions that access the work memory.
  • Page 41: Section Service Life Of The

    Memory usage and application examples 3.1 Memory usage for recipes NOTICE Service life of the SIMATIC memory card Only a limited number of delete and write operations are possible on the SIMATIC memory card. After expiration of the service life, there is a risk that the card can no longer be used.

  • Page 42
    CPU (e.g. rename, save to hard disk, delete, etc.). To avoid undesired manipulation, set access rights for the web server in STEP 7. You can find additional information on the Web server in the Web Server (http://support.automation.siemens.com/WW/view/en/59193560) function manual. ● Export of recipe data The «RecipeExport»…
  • Page 43
    Reference You can find additional information on the instructions for recipes in the STEP 7 online help under «Programming a PLC > Instructions > Instructions (S7-1200, S7-1500) > Extended instructions > Recipes and data logging > Recipe functions». Note also FAQ «Using recipe functions for persistent data with SIMATIC S7-1200 and S7 1500″…
  • Page 44: Memory Usage For Data Logging

    Memory usage and application examples 3.2 Memory usage for data logging Memory usage for data logging 3.2.1 Overview of data logging With data logging, you save selected process values from the user program in a file, the data log. The data logs are saved on the SIMATIC memory card in csv format and stored in the «datalogs»…

  • Page 45
    Memory usage and application examples 3.2 Memory usage for data logging The following figure shows the basic sequence for creating a data log: Figure 3-3 Basic sequence during the creation of a data log Structure and Use of the CPU Memory Function Manual, 10/2018, A5E03461664-AC…
  • Page 46: Data Structure Of The Data Logs

    Memory usage and application examples 3.2 Memory usage for data logging 3.2.2 Data structure of the data logs Introduction You use the «DataLogCreate» instruction to create a data log in STEP 7. The NAME parameter assigns the data log a name. The DATA and HEADER parameters specify the data type of all data elements in a data log data record, and the header line of the data log.

  • Page 47: Instructions For Data Logging

    Memory usage and application examples 3.2 Memory usage for data logging 3.2.3 Instructions for data logging Overview The following table gives an overview of the instructions for data logging. You will find the data logging instructions in «STEP 7» in the «Instructions» task card, under «Extended instructions >…

  • Page 48: Example Program For Data Logging

    10 jobs of the instructions listed in the table in parallel. You can find additional information about asynchronous instructions in the following manuals: • System manual S7-1500, ET 200MP (http://support.automation.siemens.com/WW/view/en/59191792) • System manual ET 200SP Distributed I/O System (https://support.industry.siemens.com/cs/ww/en/view/109482416)

  • Page 49
    Memory usage and application examples 3.2 Memory usage for data logging Tags of the data block The following figure shows the tags of the «My_Datalog_Vars» data block. These tags are used by the «Data logging» instructions «DataLogCreate» and «DataLogNewFile». The «MyDataLogName»…
  • Page 50
    Memory usage and application examples 3.2 Memory usage for data logging Network 2 Detect the output DONE of «DataLogCreate», because after the execution of «DataLogCreate» it is only set to 1 for one cycle. Figure 3-6 Network 2 Network 3 A rising edge triggers the point in time at which new process values are stored in the MyData structure.
  • Page 51
    Memory usage and application examples 3.2 Memory usage for data logging Network 5 Close the data log after the last data record has been written. After execution of the «DataLogWrite» instruction, which writes the last data record, the STATUS output is set to «1».
  • Page 52
    Memory usage and application examples 3.2 Memory usage for data logging Network 7 The ID parameter is an IN/OUT type. First you indicate the ID value of the existing data log whose structure you want to copy. After the «DataLogNewFile» instruction has been executed, a new and unique ID value for the new data log is written back into the address of the ID reference.
  • Page 53
    Memory usage and application examples 3.2 Memory usage for data logging In the file browser, you can download the data logs created in the example program. It is not possible to delete or rename the data logs in the Web server. To delete a data log you either use the «DataLogDelete»…
  • Page 54: Calculation Of The Data Log Size

    Memory usage and application examples 3.2 Memory usage for data logging Table 3- 2 Downloaded examples of data logs displayed in Microsoft Excel Two data records written in a data log which contains a maximum of five data records. Five data records written in a data log which contains a maximum of five data records.

  • Page 55
    Memory usage and application examples 3.2 Memory usage for data logging Header Header bytes of the data log = header character bytes + 2 bytes Header character bytes ● No data header and no time stamp = 7 bytes ● No data header and time stamp (with time stamp header) = 21 bytes ●…
  • Page 56
    Memory usage and application examples 3.2 Memory usage for data logging Data type Bytes String Example 1: MyString String[10] The maximum character string size is specified with 10 characters. Text character + automatic filling with spaces = 10 bytes • Quotation marks at the start and end + comma character = 3 bytes •…
  • Page 57
    Memory usage and application examples 3.2 Memory usage for data logging Example for size of a CSV file The figure «Open CSV file» shows a CSV file opened in a spreadsheet program with five written data records in one data log. The figure «Size of the header and the data records»…
  • Page 58: Simatic Memory Card

    SIMATIC memory card SIMATIC memory card — Overview Introduction The automation system uses a SIMATIC memory card as the program memory. The SIMATIC memory card is a preformatted memory card compatible with the Windows file system. The memory card is available in different memory sizes and can be used for the following purposes: ●…

  • Page 59
    SIMATIC memory card 4.1 SIMATIC memory card — Overview Labeling of the SIMATIC memory card ① Article number ② Serial number ③ Production version ④ Memory size ⑤ Slider for setting the write protection: Slider up: not write-protected • Slider down: write-protected •…
  • Page 60
    SIMATIC memory card 4.1 SIMATIC memory card — Overview Folders and files on the SIMATIC memory card The following folders and files can be found on the SIMATIC memory card: Table 4- 1 Folder structure Folder Description FWUPDATE.S7S Firmware update files for CPU and I/O modules SIMATIC.S7S User program, i.e.
  • Page 61
    You can find additional information on these CPUs in the CPU 1518-4 PN/DP MFP (https://support.industry.siemens.com/cs/ww/en/view/109749061) manual and the CPU 1518(F)-4 PN/DP MFP (https://support.industry.siemens.com/cs/ww/en/view/109756478) product information. You can find information on creating C/C++ runtime applications in the SIMATIC S7-1500 ODK 1500S (https://support.industry.siemens.com/cs/ww/en/view/109752683) manual. Structure and Use of the CPU Memory Function Manual, 10/2018, A5E03461664-AC…
  • Page 62
    The copy protection function is not supported by the CPUs of the redundant system S7-1500R/H. You can find additional information about copy protection in the following manuals: ● System manual S7-1500, ET 200MP Automation System (http://support.automation.siemens.com/WW/view/en/59191792) ● System manual ET 200SP Distributed I/O System (http://support.automation.siemens.com/WW/view/en/58649293)
  • Page 63
    SIMATIC memory card 4.1 SIMATIC memory card — Overview Removing a SIMATIC memory card from Windows computers If you are using the card in a commercially available card reader under Windows, use the «Eject» function before you remove the card from the card reader. If you remove the card without using the «Eject»…
  • Page 64
    You can find information on how to repair an inconsistent or incorrectly formatted card in the following FAQ on the Internet (https://support.industry.siemens.com/cs/ww/en/view/69063974). To free up memory space on your SIMATIC memory card, you have the option of formatting the SIMATIC memory card. During formatting, the entire content of the memory card is deleted with the exception of the IP address.
  • Page 65: Setting The Card Type

    SIMATIC memory card 4.2 Setting the card type Setting the card type Introduction You can use the SIMATIC memory card as a program card or as a firmware update card. Procedure 1. To set the card type, insert the SIMATIC memory card into the card reader of the programming device.

  • Page 66: Data Transfer With Simatic Memory Cards

    In this case, the service data saved beforehand is transferred to the SIMATIC memory card. You will find additional information on the service data in the following manuals: – System manual S7-1500, ET 200MP Automation System (http://support.automation.siemens.com/WW/view/en/59191792) – System manual Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833)

  • Page 67
    SIMATIC memory card 4.3 Data transfer with SIMATIC memory cards Transferring trace recordings to the SIMATIC memory card The «Save measurements on device (memory card)» function allows you to save trace recordings on your SIMATIC memory card. Note Redundant system S7-1500R/H The CPUs of the redundant system S7-1500R/H do not support the saving of measurements on the SIMATIC memory card.
  • Page 68
    ● STEP 7 online help Firmware update using SIMATIC memory card You can find information on how to perform a firmware update in the following: ● System manual S7-1500, ET 200MP Automation System (http://support.automation.siemens.com/WW/view/en/59191792) ● System manual Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833)
  • Page 69: Service Life Of The Simatic Memory Card

    SIMATIC memory card 4.4 Service life of the SIMATIC memory card Service life of the SIMATIC memory card Calculation of the theoretical service life of a SIMATIC memory card serves as a decision- making aid for selecting which card you need for your automation task. The following examples only return a guide value, however.

  • Page 70
    SIMATIC memory card 4.4 Service life of the SIMATIC memory card Maximum number of write/delete operations The internal controller of the memory card ensures that the available memory blocks are evenly used. In this way, a maximum number of write operations is possible on the SIMATIC memory card.
  • Page 71
    SIMATIC memory card 4.4 Service life of the SIMATIC memory card Guaranteed data retention time If you do not use your SIMATIC memory card for an extended period of time, there is the risk that data contained on the memory card may no longer be readable after a certain amount of time.
  • Page 72
    SIMATIC memory card 4.4 Service life of the SIMATIC memory card Calculation of the theoretical service life of a SIMATIC memory card We will use the following example as a basis for calculation: The user is using a new 256 MB memory card. In accordance with the table, this memory card type supports 200000 write operations.
  • Page 73
    Reference You can find an alternative method for calculating the service life of a SIMATIC memory card in an FAQ on the Internet (https://support.industry.siemens.com/cs/ww/en/view/109482591). GetSMCinfo instruction In STEP 7 (TIA Portal) you have the option of reading out the inserted SIMATIC memory card using the GetSMCinfo instruction.
  • Page 74: Expanding The Load Memory Of The Cpus Of The Redundant System S7-1500R/H

    SIMATIC memory card 4.5 Expanding the load memory of the CPUs of the redundant system S7-1500R/H Expanding the load memory of the CPUs of the redundant system S7-1500R/H Memory requirements If the memory space on one of the two SIMATIC memory cards is not sufficient, you can replace this card during operation of the redundant system S7-1500R/H.

  • Page 75: Glossary

    Glossary Backup CPU When the R/H system is in RUN-Redundant system state, the Primary CPU controls the process. The Backup CPU synchronously executes the user program and can take over the process control at a failure of the Primary CPU. Bit memory Bit memory is a component of the system memory of the CPU for saving intermediate results.

  • Page 76
    Glossary Diagnostics Monitoring functions include: ● Detection, localization, classification of errors, faults and alarms. ● Display and further evaluation of errors, faults and alarms. The monitoring functions run automatically during system operation. This increases the availability of systems because commissioning times and downtimes are reduced. Diagnostics buffer The diagnostics buffer is a buffered memory area in the CPU in which diagnostics events are stored in their order of occurrence.
  • Page 77
    Glossary Instance data block (DB) Each call of a function block in the STEP 7 user program is assigned a data block that is automatically generated. Values of the input, output and in/out parameters, as well as local block data, are stored in the instance data block. IP address The IP address is made up of four decimal numbers, each with a value range of 0 to 255.
  • Page 78
    Glossary Organization block Organization blocks (OBs) form the interface between the operating system of the CPU and the user program. The organization blocks determine the order in which the user program is executed. Parameter ● Variable of a STEP 7 code block ●…
  • Page 79
    Glossary Restart A restart (warm restart) deletes all non-retentive bit memory and resets non-retentive DB contents to the start values from the load memory. Retentive bit memory and retentive DB contents are retained. Program execution begins at the call of the first startup OB. Retentivity A memory area whose content is retained after power failure and after a transition from STOP to RUN is retentive.
  • Page 80
    Glossary User program In SIMATIC, a distinction is made between user programs and the firmware of the CPU. The user program contains all instructions, declarations and data that enable a plant or process to be controlled. The user program is assigned to a programmable module (e.g. CPU, FM) and can be structured in smaller units.
  • Page 81: Index

    RecipeImport, 41 WRIT_DBL, 39 C/C++, 14, 60 Counter, 29 Linux, 14, 60 Load memory, 14 Data block, 27, 33 Load memory S7-1500/H-CPUs, 73 Data logging Data structure, 45 DataLogCreate, 45 Example program, 48 Memory reserve, 32 Overview of data logging, 43…

  • Page 82
    Index Possible applications, 65 Program card, 64 Repairing, 63 Updating firmware, 67 Software change, 32 Technology objects, 28 Timer, 29 Trace recordings, 66 Web server, 14, 25, 51, 67 Work memory, 13, 15 Structure and Use of the CPU Memory Function Manual, 10/2018, A5E03461664-AC…

Документация Siemens Simatic:

Введение в STEP 7. Руководство

Программное обеспечение SIMATIC для создания программ, используемых в программируемых логических контроллерах на языках программирования контактный план, функциональный план или список операторов для станций SIMATIC S7-300/400. Основы SIMATIC STEP 7. Наиболее важные экранные диалоговые окна и процедуры, практические упражнения.

Программирование с помощью STEP 7 V5.3

Обзор программирования с помощью STEP 7.

Знакомство с продуктом и установка программного обеспечения, основы проектирования структуры программы, запуск и функционирование, сборка и редактирование проекта, определение символов, создание блоков и библиотек, логических блоков. Создание исходных файлов на STL, управление и наблюдение за переменными. Установление соединения и настройка CPU, отладка, диагностика.

SIMATIC NET NCM S7 для PROFIBUS CP

Использование коммуникационных процессоров SIMATIC NET (PROFIBUS CP) для связи по SIMATIC NET PROFIBUS на полевом уровне. Производительность и область применения коммуникационных служб. Конфигурирование CP с помощью конфигурационного программного обеспечения NCM S7. Программирование коммуникационных интерфейсов для пользовательской программы

SIMATIC NET NCM S7 для Industrial Ethernet

“PROJECT ETHERNET” Примеры STEP 7 для Ethernet CP, связь по интерфейсу SEND/RECEIVE между станциями S7. Связь по интерфейсу SEND/RECEIVE между станциями S7 и S5.

Конфигурирование аппаратуры и коммуникационных соединений STEP 7 V5.3

Обзор конфигурирования аппаратуры и проектирование соединений с помощью программного обеспечения STEP 7. Поддержка при отображении структуры аппаратного обеспечения в форме проекта STEP 7, организация обмена данными между системами автоматизации.

Первые шаги в PLC S7-200

Установка оборудования ( Монтаж). Органы управления S7-200 (CPU 212). Подключение устройства. Схема учебного устройства. Схема подключения S7-200 (CPU 212). Запуск STEP 7-Micro/WIN

Программируемый контроллер S7-200 Руководство по эксплуатации

CPU S7–200. Модули расширения S7–200. Пакет для программирования STEP 7-Micro/WIN. Возможности обмена данными. Индикаторные панели. Первые шаги. Подключение CPU S7–200. Создание программы-примера. Загрузка программы-примера

CP 243-1 Коммуникационный процессор для Industrial Ethernet

Использование коммуникационного процессора CP 243-1.Информация о том, как эксплуатировать данный коммуникационный процессор, подключенный через Industrial Ethernet (IE).

Первые шаги в PLC S7-300

Основные функции аппаратного и программного обеспечения S7–300.

Система автоматизации S7-300 Данные модулей

Общие технические данные. Источники питания. Цифровые модули. Принципы обработки аналоговых величин. Представление аналоговых величин аналоговых модулей. Аналоговые модули. Другие сигнальные модули. Интерфейсные модули. Повторитель RS 485. Наборы параметров сигнальных модулей. Диагностические данные сигнальных модулей

S7-300 CPU 31xC и CPU 31x, технические данные

Путеводитель по документации S7-300. Элементы управления и индикации. Обмен данными. Концепция памяти. Времена цикла и реакции. Общие технические данные. Технические данные CPU 31xC. Технические данные CPU31x 8.

SIMATIC S5-90U, S5-95U, S5-95F, S5-100U

Программируемый контроллер S5-95U

SIMATIC S5. Контроллер S5-100U (CPU100/CPU102). Руководство по применению.

SIMATIC S5. Контроллер SIMATIC S5-115U

Программируемые контроллеры S7-200

SIMATIC S7–200. Обзор продукта.

SIMATIC S7-300. Общие сведения. Ч1.

SIMATIC S7-300. Функциональные модули. Ч2.

S7-400. Система автоматизации S7-400. Данные CPU.

Программируемые контроллеры S7-400. Обзор.

SIMATIC S7-1200 -микроконтроллер для Totally Integrated Automation

SIMATIC S7-1500 контроллер для Totally Integrated Automation

LOGO! Руководство.

Логические модули LOGO!

Скачать документацию:

Введение в STEP 7. Руководство.

Программирование с помощью STEP 7 V5.3

SIMATIC NET NCM S7 для PROFIBUS CP

SIMATIC NET NCM S7 для Industrial Ethernet

Конфигурирование аппаратуры и коммуникационных соединений STEP 7 V5.3

Первые шаги в PLC S7-200

Программируемый контроллер S7-200 Руководство по эксплуатации

CP 243-1 Коммуникационный процессор для Industrial Ethernet

Первые шаги в PLC S7-300

Система автоматизации S7-300 Данные модулей

S7-300 CPU 31xC и CPU 31x, технические данные

SIMATIC S5-90U, S5-95U, S5-95F, S5-100U

Программируемый контроллер S5-95U

SIMATIC S5. Контроллер S5-100U (CPU100/CPU102). Руководство по применению.

SIMATIC S5. Контроллер SIMATIC S5-115U

Программируемые контроллеры S7-200

SIMATIC S7–200. Обзор продукта.

SIMATIC S7-300. Общие сведения. Ч1.

S7-400. SIMATIC S7-300. Функциональные модули. Ч2.

S7-400. Система автоматизации S7-400. Данные CPU.

Программируемые контроллеры S7-400. Обзор.

SIMATIC S7-1200 -микроконтроллер для Totally Integrated Automation

SIMATIC S7-1500 -микроконтроллер для Totally Integrated Automation

LOGO! Руководство.

Логические модули LOGO!

Программное обеспечение

S7-300 Документация. Данные модулей.

1_General_r.pdf
2_PowerSupply_r.pdf
3_Digital_r_MN.pdf
4_Analog_r_MN.pdf
5_OtherSignalModules_r.pdf
6_InterfaceModules_r.pdf
7_Repeater_r_MN.pdf
8_SIMATIC_TOP_r.pdf
GS_SM331_4-20mA_r.pdf
GS_SM331_TC_r.pdf
GS_SM331_U&PT100_r.pdf

S7-300 Документация. Данные ЦПУ.

CPU_31xC_&_CPU_31x_r.pdf

S7-300 Документация. Модуль автоматическогого регулирования FM355.

00_Preface&Contents_r_355.pdf
01_Overview_r_355.pdf
02_Settings_r.pdf
03_Work_r.pdf
04_Installing_r.pdf
05_Wiring_r.pdf
06_Assign_Parameters_r.pdf
07_User_Programm_r.pdf
08_StartingUp_r_355.pdf
09_Properties_DIO-AIO_r.pdf
10_Connecting_r.pdf
11_Assignment_DB_r.pdf
12_Faults&Diagnostics_r.pdf
13_Examples_r.pdf
Appendix_r_355.pdf

S7-300 Документация. Первые шаги.

GS_Analog_r.pdf
GS_Controlling_r.pdf
GS_Counting_r.pdf
GS_Digital_r.pdf
GS_PtP_r.pdf

S7-300 Документация. Первые шаги в пуско-наладочных работах для FM355.

get_c_r.pdf
get_s_r.pdf

S7-300 Документация. Примеры программ.

S7-300C_TF-Sample_r.pdf

S7-300 Документация Система S7-300.Руководство по инсталяции

0_Titelblatt_r.pdf
01-04_Preface_r.pdf
05_Configuring_r.pdf
06-07_Installation_r.pdf
08-09_Addressing_r.pdf
10-11_Maintenance_r.pdf
12-13-ind_Appendix_r.pdf

S7-300 Документация. Список инструкций системы S7-300.

OpList_S7-300C_r.pdf

S7-300 Документация. Технологические функции CPU 31xC.

0_Preface_Contents_r_TF.pdf
1_Overview_r.pdf
2_Positioning_r.pdf
3_Positioning_AO_r.pdf
4_Positioning_DO_r.pdf
6_Point-to-Point_r.pdf
7_Controlling_r.pdf

S7-300 Документация. Функциональный модуль FM350-1.

01_ProductOverview_r.pdf
02_HowCounts_r.pdf
04_Wiring_r.pdf
05_Assigning_Parameters_r.pdf
06_Programming_r.pdf
07_Programming_in_M7_r.pdf
08_StartingUp_r_350.pdf
09_OperatingModes_r.pdf
10_EncoderSignals_r.pdf
11_DB_Assignments_r.pdf
12_M7_Function_Library_r.pdf
13_Faults&Diagnostics_r.pdf
A_Appendix_r_350.pdf
GetStarted_FM350-1_r.pdf

S7-200 Документация S7-200 Примеры применения

Contents_r.pdf
ContentsSort_e.pdf
S72_01.pdf
S72_02.pdf
S72_03.pdf
S72_04.pdf
S72_05.pdf
S72_06.pdf
S72_07.pdf
S72_08.pdf
S72_09.pdf
S72_10.pdf
S72_11.pdf
S72_12.pdf
S72_13.pdf
S72_14.pdf
S72_15.pdf
S72_16.pdf
S72_17.pdf
S72_18.pdf
S72_19.pdf
S72_20.pdf
S72_21.pdf
S72_22.pdf
S72_23.pdf
S72_24.pdf
S72_25.pdf
S72_26.pdf
S72_27.pdf
S72_28.pdf
S72_29.pdf
S72_30.pdf
S72_31.pdf
S72_32.pdf
S72_33.pdf
S72_34.pdf
S72_35.pdf
S72_36.pdf
S72_37.pdf
S72_38.pdf
S72_39.pdf
S72_40.pdf
S72_41.pdf
S72_42.pdf
S72_43.pdf
S72_44.pdf
S72_45.pdf
S72_46.pdf
S72_47.pdf
S72_48.pdf
S72_49.pdf
S72_50.pdf
S72_51.pdf
S72_52.pdf
S72_53.pdf
S72_54.pdf
S72_55.pdf
S72_56.pdf
S72_57.pdf

Интерфейс оператора TD 200

01_Overview&Installation_r.pdf
02_Configuring_r.pdf
03_Operating_r.pdf
04_Creating_programs_r.pdf
A_Appendix_r_TD200.pdf
Titel_r.pdf

Коммуникационный модуль CP243-1

CP243-1_1ru.pdf

Коммуникационный процессор CP 243-1 IT

CP243-1it_E.pdf

Первые шаги

1steps_r.pdf

Сенсорная панель TPO70

05_TP070_r.pdf

Системное руководство СРU21x

0_Preface_r.pdf
1_Introducing_r.pdf
2_Installing_HW_r.pdf
3_Installing_SW_r.pdf
4_GettingStarted_r.pdf
5_Programming_r.pdf
6_Memory_r.pdf
7_InputOutput_r.pdf
8_Communication_r.pdf
9_Instruction_r.pdf
A_TechData_r.pdf
B_Appendix_r.pdf

Системное руководство СРU22x

0_preface.pdf
01_Owerview_r.pdf
02_GettingStarted_r.pdf
03_Installing_r.pdf
04_PLC%20Concepts_r.pdf
05_ProgrammingConcepts_r.pdf
06_InstructionSet_r.pdf
07_Communicating_r.pdf
08_TroubleShooting_r.pdf
09_PositionModule_r.pdf
10_ModemModule_r.pdf
11_USS_Protocol_r.pdf
12_ModbusProtocol_r.pdf
A_Appendix_r1.pdf
I_Index_r.pdf»
06_InstructionSet_r.pdf
10_ModemModule_r.pdf
01_Introduction_r.pdf
02_S7-200_r.pdf
03_SIPLUS_r.pdf
A_Appendix_r.pdf

MaxPlant

SIMATIC S7-1500 advanced controller





Опубликовано 13.09.2019

Промышленные контроллеры SIMATIC S7-1500

Рис. SIMATIC S7-1500

Центральные процессоры

  • Standard CPU — стандартные
  • Рис. Стандартные CPU SIMATIC S7-1500

  • Compact CPU — компактные со встроенными входами-выходами
  • Рис. Компактные CPU SIMATIC S7-1500

  • Failsafe CPU — объединяют в одном CPU функции: Standard и Safety
  • Technology CPU — объединяют в одном CPU функции: Standard, Safety и расширенные функции управления движением Motion Control
  • SIPLUS CPU — работают в экстремальных условиях
Сравнение моделей Standard CPU

CPU 1511(T)-1
PN
CPU 1513-1
PN
CPU 1515(T)-2
PN
CPU 1516-3
PN/DP
CPU 1517(T)-3
PN/DP
CPU 1518-4
PN/DP
CPU 1518-4
PN/DP ODK
Максимум модулей ввода-вывода 1024 2048 8192 16384
Рабочая память для программ 150(225) КБ 300 КБ 500(750) КБ 1 МБ 2(3) МБ 4 МБ
Рабочая память для данных 1 МБ 1,5 МБ 3 МБ 5 МБ 8 МБ 20 МБ
Рабочая память для приложений ODK 20 МБ
Производительность (битовая операция) 60 нс 40 нс 30 нс 10 нс 2 нс 1 нс
Максимальное количество блоков OB, FB, FC, DB 2000 6000 10000
Максимальный размер блоков программ OB, FB, FC 150 КБ 300 КБ 500 КБ 512 КБ
Максимальный размер блоков данных DB 1 МБ 1,5 МБ 3 МБ 5 МБ 8 МБ 16 МБ

Сравнение моделей Compact CPU

CPU 1511C-1
PN
CPU 1512C-1
PN
Рабочая память для программ 175 КБ 250 КБ
Рабочая память для данных 1 МБ 1 МБ
Производительность (битовая операция) 60 нс 48 нс
Дискретных входов-выходов 16DI/16DQ 32DI/32DQ
Аналоговых входов-выходов 5AI/2AQ 5AI/2AQ

Все CPU имеют встроенный интерфейс PROFINET с двухканальным коммутатором (2xRJ45).
CPU 1515/1516/1517 имеют один дополнительный интерфейс PROFINET со своим IP адресом.
CPU 1518 имеет два дополнительных интерфейса PROFINET со своими IP адресами.
CPU 1516/1517/1518 имеют интерфейс PROFIBUS DP.

Все CPU имеют съёмный дисплей для диагностики и ввода в эксплуатацию.

Дисплей CPU

Все CPU имеют поддержку функций управления перемещением и ПИД-регулирования.

Загрузочная память

Во всех моделях CPU в качестве загрузочной памяти (Load Memory) используется съёмная карта памяти SIMATIC Memory Card (от 4МБ до 32ГБ).
Без карты памяти контроллер работать не будет.

Web-сервер

Все CPU имеют встроенный веб-сервер с диагностической и сервисной информацией.

Сигнальные модули

Сигнальные модули делятся на классы:

  • BA (Basic) — модули без диагностики
  • ST (Standard) — с диагностикой на уровне модуля или группы каналов, класс точности для аналоговых модулей-0.3%
  • HF (High Feature)- с диагностикой на уровне каждого канала, класс точности для аналоговых модулей-0.1%
  • HS (High Speed) — с коротким временем фильтрации и преобразования аналоговых сигналов.

Сигнальные модули контроллера SIMATIC S7-1500 используются и в станциях распределённого ввода-вывода ET 200MP.

Сигнальные кабели подключаются к сигнальным модулям через съёмные фронтштекеры.

Сигнальные модули шириной 25мм поставляются в комплекте с фронтштекерами с отжимными контактами.

Для сигнальных модулей шириной 35мм фронтштекеры с контактами под винт или с отжимными контактами заказываются отдельно.

Станции распределённого ввода-вывода SIMATIC ET200 MP

Станции распределённого ввода-вывода SIMATIC ET200 MP могут подключаться к контроллерам SIMATIC S7-1500 по сети PROFINET или по сети PROFIBUS DP
с помощью интерфейсных модулей:

  • IM 155-5 PN ST
  • IM 155-5 PN HF — поддерживает протокол MRDP (Media Redundancy Protocol with Path Duplication)
  • IM 155-5 DP HF

Справа от интерфейсного модуля IM можно установить до 31 модуля из линейки контроллера SIMATIC S7-1500.

Рис. SIMATIC ET200 MP

Блоки питания

  • Системные блоки питания PS
  • Питание электроники модулей через внутреннюю шину S7-1500/ET 200MP.
    Максимум 3 блока питания на контроллер S7-1500 или станцию ET 200MP.

  • Блоки питания нагрузки PM
  • Питание внешних цепей =24В S7-1500/ET 200MP.
    Не имеет интерфейса для подключения к внутренней шине S7-1500/ET 200MP.
    Не поддерживает функции диагностики.

Языки программирования

SIMATIC S7-1500 поддерживает языки программирования: LAD, FBD, STL, SCL, GRAPH.

Среда разработки

STEP 7 Professional (TIA Portal) — среда разработки прикладных технологических программ для контроллеров: SIMATIC S7-1200, SIMATIC S7-1500,
SIMATIC S7-300, SIMATIC S7-400, WinAC.

Монтаж

Рис. Монтаж модулей SIMATIC S7-1500

Модули S7-1500 устанавливаются на профильную шину.

В один ряд можно установить до 32 модулей (включая CPU).

Внешние сигнальные кабели подключаются через съёмные фронтштекеры.

SIPLUS extreme S7-1500

Рис. SIPLUS extreme

Контроллеры SIPLUS extreme S7-1500 предназначены для эксплуатации в тяжёлых промышленных условиях:

  • возможность появления конденсата и льда
  • наличие в воздухе химически, биологически и механически активных веществ
  • диапазон рабочих температур от -40 до +70 °С.

Контроллеры SIPLUS extreme S7-1200 и SIMATIC S7-1500 имеют набор модулей с одинаковой функциональностью.

Стартовый пакет SIMATIC S7-1500

Состав стартового комплекта:

  • CPU 1511C-1 PN
  • Карта памяти SIMATIC Memory Card 4МБ
  • Блок питания PM1507, 24V/3A
  • Профильная шина 160 мм
  • Фронтальные штекеры
  • Кабель Ethernet
  • Программное обеспечение STEP 7 V15, лицензия на 365 дней
  • Документация
  • Практичный чемоданчик

Каталог SIMATIC ST 70 • 2019

Обложка каталога ST70

Скачать полный каталог на английском языке (50,4 Мб)

Спецификация SIMATIC S7-1500

Обозначения:
PN — PROFINET
DP — PROFIBUS DP
DI/DQ — дискретные входы/выходы, AI/AQ — аналоговые входы/выходы

SM — сигнальные модули
Классы сигнальных модулей: BA (Basic), ST (Standard), HF (High Feature), HS (High Speed)

Данные для заказа

N Описание Заказной номер
Центральные процессоры CPU
1 CPU 1511-1 PN 6ES7511-1AK01-0AB0
2 CPU 1511F-1 PN 6ES7511-1FK02-0AB0
3 CPU 1511C-1 PN 16DI/16DQ, 5AI/2AQ 6ES7511-1CK00-0AB0
3 CPU 1511T-1 PN 16DI/16DQ, 5AI/2AQ 6ES7511-1TK00-0AB0
4 CPU 1512C-1 PN 32DI/32DQ, 5AI/2AQ 6ES7512-1CK01-0AB0
5 CPU 1513-1 PN 6ES7513-1AL01-0AB0
6 CPU 1513F-1 PN 6ES7513-1FL02-0AB0
7 CPU 1515-2 PN 6ES7515-2AM01-0AB0
8 CPU 1515T-2 PN 6ES7515-2TM01-0AB0
9 CPU 1515F-2 PN 6ES7515-2FM01-0AB0
10 CPU 1516-3 PN/DP 6ES7516-3AN01-0AB0
11 CPU 1516F-3 PN/DP 6ES7516-3FN01-0AB0
12 CPU 1517-3 PN/DP 6ES7517-3AP00-0AB0
13 CPU 1517T-3 PN/DP 6ES7517-3TP00-0AB0
14 CPU 1517F-3 PN/DP 6ES7517-3FP00-0AB0
15 CPU 1518-4 PN/DP 6ES7518-4AP00-0AB0
16 CPU 1518F-4 PN/DP 6ES7518-4FP00-0AB0
17 CPU 1518-4 PN/DP ODK 6ES7518-4AP00-3AB0
Карты памяти SIMATIC Memory Card
18 4МБ 6ES7954-8LC02-0AA0
19 12МБ 6ES7954-8LE02-0AA0
20 24МБ 6ES7954-8LF02-0AA0
21 256МБ 6ES7954-8LL02-0AA0
22 2ГБ 6ES7954-8LP02-0AA0
23 32ГБ 6ES7954-8LT02-0AA0
Модули ввода дискретных сигналов
24 SM 1521 DI 32x24VDC BA, 3мс, тип 3, 25мм, с фронтштекером 6ES7521-1BL10-0AA0
25 SM 1521 DI 32x24VDC HF, 3мс, тип 3, 35мм 6ES7521-1BL00-0AA0
26 SM 1521 DI 16x24VDC BA, 3мс, тип 3, 25мм, с фронтштекером 6ES7521-1BH10-0AA0
27 SM 1521 DI 16x24VDC HF, 3мс, тип 3, 35мм 6ES7521-1BH00-0AA0
28 SM 1521 DI 16x24VDC SRC BA, 3мс, тип 1, минус на общей точке, 35мм 6ES7521-1BH50-0AA0
29 SM 1521 DI 16x230VAC BA, 20мс, тип 1, 35мм 6ES7521-1FH00-0AA0
30 SM 1521 DI 16×24…125VUC HF, 0.05…20мс, тип 3, 35мм 6ES7521-7EH00-0AB0
Модули вывода дискретных сигналов
31 SM 1522 DQ 32x24VDC/0.5A BA, 25мм, с фронтштекером 6ES7522-1BL10-0AA0
32 SM 1522 DQ 32x24VDC/0.5A ST, 35мм 6ES7522-1BL00-0AB0
33 SM 1522 DQ 32x24VDC/0.5A HF, 35мм 6ES7522-1BL01-0AB0
34 SM 1522 DQ 16x24VDC/0.5A BA, 25мм, с фронтштекером 6ES7522-1BH10-0AA0
35 SM 1522 DQ 16x24VDC/0.5A ST, 35мм 6ES7522-1BH00-0AB0
36 SM 1522 DQ 16x24VDC/0.5A HF, 35мм 6ES7522-1BH01-0AB0
37 SM 1522 DQ 8x230VAC/5A ST, реле, 35мм 6ES7522-5HF00-0AB0
38 SM 1522 DQ 16x230VAC/2A ST, реле, 35мм 6ES7522-5HH00-0AB0
39 SM 1522 DQ 8x230VAC/2A ST, тиристоры, 35мм 6ES7522-5FF00-0AB0
40 SM 1522 DQ 16x230VAC/1A ST, тиристоры, 35мм 6ES7522-5FH00-0AB0
41 SM 1522 DQ 16×24…48VUC/125VDC/0.5A ST, тиристоры, 35мм 6ES7522-5EH00-0AB0
Модуль ввода-вывода дискретных сигналов
42 SM 1523 DI 16x24VDC + DQ 16x24VDC/0.5A BA, 25мм, с фронтштекером 6ES7523-1BL00-0AA0
Модули ввода аналоговых сигналов
43 SM 1531 AI 8xU/I/RTD/TC ST, 16 бит, 0.3%, 35мм 6ES7531-7KF00-0AB0
44 SM 1531 AI 8xU/I HS, 14 бит, 0.3%, 35мм 6ES7531-7NF10-0AB0
45 SM 1531 AI 8xU/I HF, 16 бит, 0.1%, 35мм 6ES7531-7NF00-0AB0
46 SM 1531 AI 4xU/I/RTD/TC ST, 16 бит, 25мм, с фронтштекером 6ES7531-7QD00-0AB0
47 SM 1531 AI 8xU/I/RTD/TC HF, 16 бит, 0.1%, 35мм 6ES7531-7PF00-0AB0
Модули вывода аналоговых сигналов
48 SM 1532 AQ 8xU/I HS, 14 бит, 0.3%, 35мм 6ES7532-5HF00-0AB0
49 SM 1532 AQ 4xU/I ST, 16 бит, 0.3%, 35мм 6ES7532-5HD00-0AB0
50 SM 1532 AQ 2xU/I ST, 25мм, с фронтштекером 6ES7532-5NB00-0AB0
51 SM 1532 AQ 4xU/I HF, 16 бит, 0.1%, 35мм 6ES7532-5ND00-0AB0
Модули ввода-вывода аналоговых сигналов
52 SM 1534 AI 4xU/I/RTD/TC AQ 2xU/I ST, 25мм, с фронтштекером 6ES7534-7QE00-0AB0
Коммуникационные модули
53 CM PtP CM PtP RS232 BA: Freeport, 3964(R), USS 6ES7540-1AD00-0AA0
54 CM PtP CM PtP RS422/RS485 BA: Freeport, 3964(R), USS 6ES7540-1AB00-0AA0
55 CM PtP CM PtP RS232 HF: Freeport, 3964(R), USS, Modbus RTU 6ES7541-1AD00-0AB0
56 C PtP CM PtP RS422/RS485 HF: Freeport, 3964(R), USS, Modbus RTU 6ES7541-1AB00-0AB0
57 CP 1543-1 Industrial Ethernet: TCP/IP, ISO, UDP, S7, Firewall, SNMPV1/V3, DHCP, FTP клиент, 1xRJ45 6GK7543-1AX00-0XE0
58 CM 1542-5 Коммуникационный модуль CM 1542-5 PROFIBUS DP 6GK7542-5DX00-0XE0
59 CP 1542-5 Коммуникационный процессор CP 1542-5 PROFIBUS DP 6GK7542-5FX00-0XE0
60 CP 1542-1 Коммуникационный процессор CP 1542-1 PN IO-Controller, TCP/IP, UDP, S7, ISO-ON-TCP 6GK7542-1AX00-0XE0
Технологические модули
61 TM Count TM Count 2x24V — 2-канальный модуль скоростного счёта 6ES7550-1AA00-0AB0
62 TM PosInput TM PosInput 2 — 2-канальный модуль для подключения датчиков позиционирования 6ES7551-1AB00-0AB0
63 TM Timer TM Timer DIDQ 16x24V — сигналы с меткой времени 6ES7552-1AA00-0AB0
64 SIWAREX WP521 1-канальный модуль взвешивания статических грузов 7MH4980-1AA01
65 SIWAREX WP522 2-канальный модуль взвешивания статических грузов 7MH4980-2AA01
Интерфейсные модули для станции распределённого ввода-вывода SIMATIC ET 200MP
66 IM 1555-5 PN Интерфейсный модуль IM 1555-5 PN ST 6ES7155-5AA01-0AB0
67 IM 1555-5 PN Интерфейсный модуль IM 1555-5 PN HF 6ES7155-5AA00-0AC0
68 IM 1555-5 DP Интерфейсный модуль IM 1555-5 DP HF 6ES7155-5BA00-0AB0
Блок питания нагрузки
69 PM 1507 70 Вт, вход: ~115/230В, выход: =24В/3А 6EP1332-4BA00
70 PM 1507 190 Вт, вход: ~115/230В, выход: =24В/8А 6EP1333-4BA00
Системные блоки (питание электроники по внутренней шине)
71 PS 1505 25 Вт, =24В 6ES7505-0KA00-0AB0
72 PS 1505 60 Вт, =24/48/60В 6ES7505-0RA00-0AB0
73 PS 1505 HF 60 Вт, =24/48/60В 6ES7505-0RB00-0AB0
74 PS 1507 60 Вт, AC/DC 120/230В 6ES7507-0RA00-0AB0
Профильные шины S7-1500
75 160 мм 6ES7590-1AB60-0AA0
76 482 мм 6ES7590-1AE80-0AA0
77 530 мм 6ES7590-1AF30-0AA0
78 830 мм 6ES7590-1AJ30-0AA0
79 2000 мм 6ES7590-1BC00-0AA0
Фронтштекеры для модулей шириной 35 мм
80 40-полюсный с отжимными контактами 6ES7592-1BM00-0XB0
81 40-полюсный с контактами под винт 6ES7592-1AM00-0XB0
Запасной дисплей
82 для CPU 1511-1 PN, CPU 1511F-1 PN, CPU 1511C-1 PN, CPU 1512C-1 PN,
CPU 1513-1 PN, CPU 1513F-1 PN3
6ES7591-1AA00-0AA0
83 для CPU 1515(F)-2 PN, CPU 1516(F)-3 PN/DP, CPU 1517 (F)-3 PN/DP, CPU 1518(F)-4 PN/DP 6ES7591-1BA00-0AA0
Запасные части
84 Универсальная крышка для IM 155-5 PN ST, 5 шт. 6ES7528-0AA70-7AA0
85 фронтштекер 25 мм, push-in 6ES7592-1BM00-0XA0
86 U-образный шинный соединитель, 5 шт. 6ES7590-0AA00-0AA0
87 Разъём питания, 2х2 полюса, для модуля ввода-вывода =24В, 10 шт. 6ES7193-4JB00-0AA0
88 Универсальная крышка для модуля ввода-вывода S7-1500, 5 шт. 6ES7528-0AA00-7AA0
89 Маркировочные этикетки для модулей, 10 шт. 6ES7592-2AX00-0AA0
90 Набор заземления экрана соединительного кабеля, 5 комплектов 6ES7590-5CA00-0AA0
91 Терминал заземления, 5 шт. 6ES7590-5BA00-0AA0
92 Коммутационная пермычка для фронтштекеров, 20 шт. 6ES7592-3AA00-0AA0
93 Элемент заземления профильной шины 2000мм, 20 шт. 6ES7590-5AA00-0AA0
Программное обеспечение
94 STEP7 Professional V15 6ES7822-1AA05-0YA5
95 ODK 1500S V2.0 6ES7806-2CD02-0YA0
Стартовый комплект SIMATIC S7-1500
96 CPU 1511C-1 PN, блок питания PM 1507, профильная рейка 160мм, DI16x24VDC, DQ16x24VDC/0.5A,
фронтштекеры, кабель Ethernet, лицензия STEP7 Professional V15 на 365 дней, документация
6ES7511-1CK00-4YB5
                                                                




Понравилась статья? Поделить с друзьями:
  • Бетадин повидон йод инструкция по применению раствор
  • Должностная инструкция инструктора по плаванию в школе
  • Руководство ифнс по москве официальный сайт
  • Руководство по gpart
  • Капли для глаз диклофенак цена инструкция по применению взрослым