Ups keor lp 2000va инструкция legrand

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

Index

KEOR LP 1, 2, 3 kVA

26

26

28

30

31

34

39

40

43

25

loading

Related Manuals for LEGRAND Keor LP

Summary of Contents for LEGRAND Keor LP

  • Page 1: Table Of Contents

    KEOR LP 1, 2, 3 kVA Index 1 Introduction 2 Condition of use 3 LED Panel 4 Rear Panel 5 Installation 6 Functions and Signal 7 UPS software 8 Possible malfunctioning 9 Technical features…

  • Page 2: Introduction

    • The front control panel is provided for manual operations; Do not press on the panel with sharp or pointed objects. • The UPS Keor LP has been designed to work in closed, clean rooms where there are no inflammable liquids or corrosive substances and where it is not too damp.

  • Page 3
    KEOR LP 1, 2, 3 kVA Do not place the UPS in a dusty or corrosive environment or near any flammable objects. This UPS is not designed for outdoor use. 0%~90% • Keep the ventilation slits clean to dissipate the heat of the UPS.
  • Page 4: Led Panel

    ® 3 LED Panel Control Symbol Description a. UPS Power-On Switch (Press and hold until the buzzer beeps.) b. Alarm silence c. Error Code Display Mode After an alarm, press to mute the alarm buzzer and show an Error Code. (Do not hold for > 1 second.) UPS Power-Off Switch (Press and hold until the buzzer beeps.) a.

  • Page 5
    KEOR LP 1, 2, 3 kVA Symbol Description Indicator 1. Steadily on indicates normal utility voltage. Blinking indicates insufficient utility voltage for the full load. Off indicates abnormal Normal utility voltage. Mode LED 2. In Battery/Load Test Mode indicates battery capacity is 50%.
  • Page 6: Rear Panel

    ® 4 Rear panel 3 101 54 3 101 56 3 101 58 3 101 55 3 101 57 3 101 59 1. Slot for optional communication cards 2. Emergency Power Off (EPO) dry contact signal inputs 3. NA 4. RS-232 port 5.

  • Page 7: Installation

    KEOR LP 1, 2, 3 kVA 5 Installation Unpacking Inspect the UPS upon receipt After removing the packing foam please be careful handling the UPS while it is still in the plastic bag and check for the following standard package contents : http://ups.legrand.com/biblioteca/…

  • Page 8
    ® 5 Installation The following main connections are available on the rear of the uninterruptible power supply : • Output sockets (6) and input connector (8). • Socket for connecting computer serial interface RS232 (9 female pins) [4]: required when using the diagnostic and shutdown management software.
  • Page 9
    KEOR LP 1, 2, 3 kVA five seconds. At the same time, the fan at the front of the UPS will start operating. 5. Press and hold the ON button for approximately one second to start the UPS. The buzzer will beep and the LED indicators will shine after 1-5 seconds.
  • Page 10: Functions And Signal

    ® 6 Functions and Signals Beep Codes The following table contains common UPS statuses with their beep codes. UPS Status Beep Code UPS faulty, Inverter shut down. All functions inhibited. Long Continuous Beep Control keypad error Long Continuous Beep UPS faulty, loads continue to be supplied via Inverter or Bypass. Single beep every two seconds In battery mode Single beep once per second…

  • Page 11
    KEOR LP 1, 2, 3 kVA The table below provides a summary of the UPS operating modes under various utility AC power source and battery conditions. Utility Condition UPS Operating Mode LEDs Working power starts after approximately LED ON 5 seconds, LEDs on the panel will blink and…
  • Page 12
    ® 6 Functions and Signals When Utility is Abnormal or Absent The operating mode of the UPS under abnormal utility conditions is illustrated as follows. Figure 5.3 1. When the utility is abnormal the UPS will direct the battery energy automatically to the Inverter without delay and turn off the charger and AC/DC converter.
  • Page 13
    KEOR LP 1, 2, 3 kVA 1. Generally, modern electronics and IT equipment generate an inrush current when switching on. The amount of inrush current varies from equipment to equipment, sometimes as high as six times rated capacity, other times negligible. To prevent severe damage to its inverter caused by the inrush produced by the loads, the UPS is equipped with an electronic overload-protection feature as standard.
  • Page 14
    ® 6 Functions and Signals Overheating If the UPS overheats when the utility is normal it will switch into bypass mode. The UPS will switch back to inverter mode when the overheating is eliminated. If overheating occurs when the utility is abnormal the buzzer will beep continuously and the Fault will shine.
  • Page 15: Ups Software

    KEOR LP 1, 2, 3 kVA 7 UPS software From the website www.ups.legrand.com it is possible to download UPS software. This software can be used for the following functions: — Automatic shutdown of the local computer — UPS parameters reading…

  • Page 16: Possible Malfunctioning

    ® 8 Possible malfunctioning Troubleshooting Problem Check Items Solution 1. Check for proper battery connection. Measure battery voltage to ensure that batteries are charged and healthy. Recharge batteries for 8 1. Er05,Er24 hours if necessary. Simulate utility outage to verify that UPS is able to provide DC backup.

  • Page 17
    KEOR LP 1, 2, 3 kVA Problem Check Items Solution The UPS switches into 1. A power strip is battery mode and then back connected to the 1. Do not use the power strip. into utility mode when a UPS. See if there 2.
  • Page 18
    ® 8 Possible malfunctioning Error Codes When the Fault LED is lit press the ON button briefly to check the error code. The error codes 1, 2, 4, 8, and 16 are represented by the four bar LEDs 25%, 50%, 75%, and 100%, and the Overload LED Each LED represents a number as shown in the figure below.
  • Page 19: Technical Features

    KEOR LP 1, 2, 3 kVA 9 Technical features 3 101 54 3 101 56 3 101 58 MODEL ITEM 3 101 55 3 101 57 3 101 59 1000 VA 2000 VA 3000 VA Capacity when input voltage is 210~240Vac PF=0.9 (900/1800/2700W) Power Factor when input voltage is 185~260Vac PF=0.8 (800/1600/2400W)

  • Page 20
    ® 9 Technical features 3 101 54 3 101 56 3 101 58 MODEL ITEM 3 101 55 3 101 57 3 101 59 <105% continuous 106-120% for 30 seconds Line 121-150% for 10 seconds mode >150% Immediately transfer to bypass. Buzzer continuously alarms.
  • Page 21
    KEOR LP 1, 2, 3 kVA 3 101 54 3 101 56 3 101 58 MODEL ITEM 3 101 55 3 101 57 3 101 59 Battery Recharge time (to 90%) DC start Self By panel button or software control…
  • Page 22
    ® 9 Technical features 3 101 54 3 101 56 3 101 58 MODEL ITEM 3 101 55 3 101 57 3 101 59 Unit Dimensions 236 × 144 × 367 322 x 151 x444 322 × 189 × 444 (HxWxD in mm) Physical Weight…

инструкцияLegrand KEOR LP

Part. LE07381AC-10/17-01 GF

KEOR LP BATTERY BANK

1, 2, 3 kVA

Manuel d’installation Installation manual

Посмотреть инструкция для Legrand KEOR LP бесплатно. Руководство относится к категории Без категории, 1 человек(а) дали ему среднюю оценку 7.5. Руководство доступно на следующих языках: английский. У вас есть вопрос о Legrand KEOR LP или вам нужна помощь? Задайте свой вопрос здесь

Главная
Вес и размеры
Высота 322 mm
Ширина 151 mm
Глубина 444 mm
Вес 31000 g
Высота 322 mm
Ширина 151 mm
Глубина 444 mm
Вес 31000 g
Условия эксплуатации
Диапазон температур при эксплуатации 0 — 40 °C
Диапазон относительной влажности при эксплуатации 20 — 80 %
Диапазон температур при эксплуатации 0 — 40 °C
Диапазон относительной влажности при эксплуатации 20 — 80 %
Дизайн
Формат Tower
Цвет товара Черный
Совместимые продукты KEOR LP 2kVA
Содержимое упаковки
Сертификаты
Сертификация EN 62040-1, EN 62040-2
Свойства
Цвет товара Черный
Сертификация EN 62040-1, EN 62040-2
Совместимость KEOR LP 2kVA
Напряжение батареи 48 V
Батарея

показать больше

Не можете найти ответ на свой вопрос в руководстве? Вы можете найти ответ на свой вопрос ниже, в разделе часто задаваемых вопросов о Legrand KEOR LP.

Какой вес Legrand KEOR LP?

Какие сертификаты Legrand KEOR LP имеет?

Какая высота Legrand KEOR LP?

Какая ширина Legrand KEOR LP?

Какая толщина Legrand KEOR LP?

Инструкция Legrand KEOR LP доступно в русский?

Не нашли свой вопрос? Задайте свой вопрос здесь

Посмотреть все Legrand руководства Посмотреть все Legrand Без категории руководства

Table of Contents for LEGRAND KEOR LP:

  • 113 KEOR LP 1, 2, 3 kVA NL Index 1 Inleiding 114 2 Gebruiksvoorwaarden 114 3 Ledpaneel 116 4 Achterpaneel 118 5 Installatie 119 6 Functies en signalen 122 7 UPS Software 127 8 Problemen oplossen 128 9 Technische kenmerken 131

  • 13 KEOR LP 1, 2, 3 kVA FR Le tableau ci-dessous résume le fonctionnement de l’ASI sous différentes puissances et conditions des batteries. Fonctionnement en secteur Normal Le mode de fonctionnement de l’onduleur dans des conditions normales d’utilisation est illustré comme suit : Lorsque l’utilisation est normale, la source de courant alternatif est redressée en courant continu et introduit dans le

  • 45 KEOR LP 1, 2, 3 kVA EN MODEL ITEM 3 101 54 3 101 55 3 101 56 3 101 57 3 101 58 3 101 59 Battery Recharge time (to 90%) 3hr DC start Yes Self Diagnostics By panel button or software control Front Panel LED Load Level/Battery Level/ Battery Mode/ Normal Mode/ Bypass Mode/ Self-Test/ Weak/Bad Battery/Site Wiring Fault/ Fault/ Overload Button ON (Alarm Silence)/ OFF (Test/Level Button) Audible Alarm Battery Mode Sounds once every 1.5 seconds Low Battery Sounds once every 0.2 seconds Overload Sounds once every 3 se

  • 34 ® 6 Functions and Signals Beep Codes The following table contains common UPS statuses with their beep codes. UPS System Block Diagram Figure 5.1 illustrates the True On-Line Double Conversion architecture of the UPS system. The major modules consist of: 1) AC-to-DC power converter (rectifier) with PFC control circuit 2) DC-to-AC high frequency inverter 3) Smart battery charger 4) Bank of stationary, maintenance-free batteries 5) DC-to-DC push/pull co

  • 83 KEOR LP 1, 2, 3 kVA DE 7 Software Sie können die Software der USV von der Website www.ups.legrand.com herunterladen. Diese Software kann für folgende Funktionen verwendet werden: — Automatisches Abschalten des lokalen Computers, der über die RS232-Schnittstelle an die USV angeschlossen ist. — Ablesen der USV-Parameter Anschluss Das Kabel der RS232-Schnittstelle an den Port an der Rückseite der USV und an den Port des Computers anschließen.

  • 12 ® 6 Fonctions et signaux Codes sonores Le tableau suivant contient des statuts communs ASI avec leurs codes sonores. Schéma Bloc de l’ASI Figure 5.1 illustre la véritable On-line double conversion du système ASI. Les principaux modules sont constitués de : 1) Un AC-to-DC convertisseur de puissance (redresseur) avec PFC circuit de commande 2) Un DC-to-AC inverter haute fréquence 3) Un chargeur batteries 4) Batteries sans entretien 5) Un contrôleur de la conversion

  • 23 KEOR LP 1, 2, 3 kVA FR MODEL ITEM 3 101 54 3 101 55 3 101 56 3 101 57 3 101 58 3 101 59 Batterie Temps de recharge (à 90%) 3hr Démarrage DC Oui Auto diagnostique Par action sur le bouton du panneau ou par contrôle logiciel Panneau avant LED Niveau de charge/Batterie Niveau/ Batterie Mode/ Normal Mode/Bypass Mode/ Auto-Test/ Faible/Batterie défectueuse/Défaut câblage/ Défaut/ Surcharge Bouton ON (Alarme Silence)/ OFF (Test/Bouton Niveau) Alarme sonore Mode Batterie Sonne une

  • 146 ® 6 Управление и сигнализация Если напряжение сети не в норме или отсутствует     ,      . 1.     , 

  • 150 ® 8 Возможные неисправности Поиск и устранение неисправностей Неисправность Что проверяется Действия по устранению   «».    (Er)* (.  ), �

  • 138 ® 3 ЖК дисплей Кнопка управления Символ Описание ВКЛ. 1 2 a.    (  ,     ) b.   c.   

  • 40 ® 8 Possible malfunctioning Troubleshooting Problem Check Items Solution Fault LED Read the error code* (see next page) displayed by the combination of LEDs, and verify the fault as follows. 1. Er05,Er24 1 2 1. Check for proper battery connection. Measure battery voltage to ensure that batteries are charged and healthy. Recharge batteries for 8 hours if necessary. Simulate utility outage to verify that UPS is able to provide DC backup. Otherwise consult your local dealer right away. 2. Ove

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of LEGRAND KEOR LP device using right now.

  • 68, 68 ® 9 Caratteristiche tecniche MODELLO ITEM 3 101 54 3 101 55 3 101 56 3 101 57 3 101 58 3 101 59 Pesi e misure Dimensioni (H x l x p in mm) 236 × 144 × 367 322 x 151 x444 322 × 189 × 444 Peso (Kg) 10kg 16.5kg 22.5kg Ambiente Temperatura di funzionamento 0-40°C Livello di rumorosità < 50 dBA Tasso di umidità 0-90% (non condensante) Interfaccia Ti…

  • 100, 100 ® 6 Funciones y señalizaciones Códigos de señalización acústica La tabla siguiente contiene una lista de los estados comunes del SAI y sus señalizaciones acústicas correspondientes. Esquema de bloques del SAI La figura 5.1 representa una verdadera conversión doble en línea del sistema SAI. Los módulos principales están constituidos por: 1)…

  • 138, 138 ® 3 ЖК дисплей Кнопка управления Символ Описание ВКЛ. 1 2 a.    (  ,      ) b.   c. �…

  • 86, 86 ® Fehlercodes Wenn die Leuchte Störung 1 2 leuchtet, die Tasten ON 1 2 kurz drücken, um den Fehlercode zu kontrollieren. Die Fehlercode 1, 2, 4, 8, und 16 werden durch die 4 Balken 25%, 50%, 75%, und 100%, und die Meldeleuchte für Überlast 1 2 . dargestellt. Jede LED stellt eine Nummer dar, wie in der nachfolgenden Abbildung gezeigt. Es…

  • 16, 16 ® 6 Fonctions et signaux Surchauffe de l’onduleur Si l’ASI surchauffe en condition d’alimentation secteur normal, il passe en mode bypass. Il retourne en mode onduleur lorsque celle-ci est éliminée. En cas de surchauffe, lorsque le réseau présente des anomalies, le buzzer émet un bip continu, le voyant 1 2 de défaut s’allume et l’onduleur coupe l’ali…

  • 156, 156 ® 9 Технические характеристики 3 101 54 3 101 55 3 101 56 3 101 57 3 101 58 3 101 59    ( x  x , ) 236 × 144 × 367 322 x 151 x 444 322 × 189 × 444  10  16,5  22,5   �…

  • 155, 155 KEOR LP 1, 2, 3 kVA RU KEOR LP 1, 2, 3 kVA 3 101 54 3 101 55 3 101 56 3 101 57 3 101 58 3 101 59    (90%) 3             …

  • 116, 116 ® 3 Ledpaneel 1 2 Toetsen Symbool Beschrijving ON 1 2 a. Knop om de UPS in te schakelen. (Druk en houd de knop ingedrukt totdat u een piep hoort). b. Het alarm geluid uitschakelen c. Weergave foutcodes Druk na een alarm op deze knop om het geluidssignaal uit te schakelen en de foutcode te bekijken. (Druk de knop niet langer dan 1 seconde in) OFF 1 2 Knop ‘uit…

  • 140, 140 ® 4 Задняя панель 1.      2.           (EPO) 3. �…

  • 147, 147 KEOR LP 1, 2, 3 kVA RU   1.    IT     .       …

  • 115, 115 KEOR LP 1, 2, 3 kVA NL • Plaats de UPS niet in een stoffige of agressieve omgeving of in de nabijheid van brandbare objecten. Deze UPS is niet ontworpen voor buiten gebruik. • Houd de ventilatieopeningen schoon en bedek ze niet, zodat de interne warmte van de UPS kan wor- den afgevoerd. Plaats niets op de UPS. Bewaar steeds 20 cm afstand tussen het achterpaneel van de …

  • 127, 127 KEOR LP 1, 2, 3 kVA NL 7 UPS Software U kunt de software van de UPS downloaden op de website www.ups.legrand.com. Die software heeft de volgende functies: — De plaatselijke pc die is aangesloten op de UPS via RS232 automatisch gecontroleerd uitschakelen. — De parameters van de UPS raadplegen. Aansluiting Het is mogelijk om RS-232 communicatie te gebruiken Sluit d…

  • 8, 8 ® 4 Panneau arrière 1 2 3 6 1 2 3 6 5 1 7 8 4 1 2 3 6 8 7 5 9 4 8 7 5 4 1 2 3 6 1 8 7 5 4 1 2 3 6 5 7 8 4 1 2 3 6 8 5 9 7 4 1. Slot pour carte de communication 2. Arrêt d’urgence (EPO) 3. Non disponible 4. Port RS-232 5. Connecteur batteries externes 6. Prises de sorties 7. Porte fusible d’entrée 8. Prise d’entrée alimentation 9. Porte fusible de sortie. Pour 2 s…

  • 152, 152 ® 8 Возможные неисправности Коды ошибок    «» 1 2 ,     1 2 ,     . …

  • 87, 87 KEOR LP 1, 2, 3 kVA DE 9 Technische Daten 9 Technische Daten MODELL ARTIKEL 3 101 54 3 101 55 3 101 56 3 101 57 3 101 58 3 101 59 Kapazität VA 1000 VA 2000 VA 3000 VA Leistungsfaktor Spannungsintervall am Eingang 210~240Vac PF=0,9(900/1800/2700W ) Spannungsintervall am Eingang 185~240Vac PF=0,8(800/1600/2400W ) Spannungsintervall am Eingang 160~240Vac PF=0,7(700/1400/2100…

  • 34, 34 ® 6 Functions and Signals Beep Codes The following table contains common UPS statuses with their beep codes. UPS System Block Diagram Figure 5.1 illustrates the True On-Line Double Conversion architecture of the UPS system. The major modules consist of: 1) AC-to-DC power converter (rectifier) with PFC control circuit 2) DC-to-AC high frequency inverter 3) Smart battery charger 4) Bank…