- Manuals
- Brands
- Delta Manuals
- DC Drives
- VFD015B43A
Manuals and User Guides for Delta VFD015B43A. We have 2 Delta VFD015B43A manuals available for free PDF download: Manual, User Manual
Delta VFD015B43A Manual (251 pages)
Brand: Delta
|
Category: Controller
|
Size: 4.22 MB
Table of Contents
-
Preface
1
-
Table of Contents
3
-
Receiving and Inspection
9
-
Nameplate Information
9
-
Model Explanation
9
-
-
Chapter 1 Introduction
9
-
Appearances
10
-
Series Number Explanation
10
-
Drive Frames
10
-
-
Preparation for Installation and Wiring
12
-
Remove Keypad
12
-
Remove Front Cover
14
-
-
Lifting
15
-
Storage
16
-
Installation and Wiring
19
-
Ambient Conditions
19
-
-
Chapter 2 Installation and Wiring
19
-
Dimensions
21
-
General Wiring Information
30
-
Basic Wiring
31
-
Wiring for SINK Mode and SOURCE Mode
35
-
External Wiring
36
-
2.4.3 Main Terminals Connections
37
-
Control Circuit Terminals
37
-
Mains Power Terminals
37
-
Circuit Diagram for Digital Inputs
39
-
-
Control Terminals
39
-
Grounding Terminals
39
-
Terminal Symbols and Functions
40
-
Analog Input Terminals
43
-
Digital Inputs
43
-
Digital Outputs
43
-
General
43
-
-
Main Circuit Terminals
45
-
-
Preparations before Start-Up
53
-
-
Chapter 3 Start up
53
-
Operation Method
54
-
Trial Run
54
-
Description of the Digital Keypad VFD-PU01
57
-
-
Chapter 4 Digital Keypad Operation
57
-
How to Operate the Digital Keypad VFD-PU01
59
-
-
Chapter 5 Parameters
61
-
Summary of Parameter Settings
62
-
User Parameters
62
-
Operation Method Parameters
64
-
Output Function Parameters
67
-
Input Function Parameters
68
-
Multi-Step Speed and PLC Parameters
70
-
Protection Parameters
72
-
Motor Parameters
74
-
Special Parameters
74
-
Communication Parameters
76
-
PID Control Parameters
76
-
Fan and Pump Control Parameters
77
-
-
Parameter Settings for Applications
78
-
Speed Search
78
-
DC Braking before Running
78
-
Motor Power Switch-Over between AC Motor Drive and Commercial Power
79
-
Energy Saving
79
-
Multi-Step Operation
79
-
Switching Acceleration and Deceleration Times
79
-
Overheat Warning
80
-
Two-Wire/Three-Wire
80
-
Operation Command
80
-
Frequency Hold
81
-
Auto Restart after Fault
81
-
Emergency Stop by DC Braking
81
-
Over-Torque Setting
81
-
Skip Frequency Setting
82
-
Carrier Frequency Setting
82
-
Keep Running When Frequency Command Is Lost
82
-
Display the Speed of Load
82
-
Output Signal in Zero Speed
83
-
Output Signal at Desired Frequency
83
-
Output Signal for Base Block
83
-
Overheat Warning for Heat Sink
83
-
-
Description of Parameter Settings
84
-
Identity Code of the AC Motor Drive
84
-
Rated Current Display of the AC Motor Drive
84
-
Parameter Reset
85
-
Start-Up Display Selection
85
-
Content of Multi-Function Display
85
-
User Defined Coefficient K
86
-
Software Version
87
-
Password Input
87
-
Password Set
87
-
Basic Parameters
90
-
Maximum Output Frequency
90
-
Maximum Voltage Frequency
90
-
Maximum Output Voltage
90
-
MID-Point Voltage
91
-
Minimum Output Frequency
91
-
Minimum Output Voltage
91
-
Output Frequency Upper Limit
91
-
Output Frequency Lower Limit
92
-
Deceleration Time 4
93
-
Accel/Decel Time Unit
93
-
Jog Acceleration Time
94
-
Jog Deceleration Time
94
-
Jog Frequency
94
-
Auto-Acceleration / Deceleration
95
-
Deceleration S-Curve
96
-
Source of First Master Frequency Command
97
-
Source of Second Master Frequency Command
97
-
Source of First Operation Command
98
-
Source of Second Operation Command
98
-
Source of the Master Frequency Command
98
-
Source of the Auxiliary Frequency Command
99
-
Combination of the Master and Auxiliary Frequency Command
99
-
Stop Method
99
-
PWM Carrier Frequency Selections
101
-
Motor Direction Control
101
-
2-Wire/ 3-Wire Operation Control Modes
102
-
Line Start Lockout
103
-
Loss of ACI Signal (4-20Ma)
105
-
Up/Down Mode
105
-
Accel/Decel Rate of Change of UP/DOWN Operation with Constant Speed
106
-
Keyboard Frequency Command
106
-
Multi-Function Output Terminals
107
-
Desired Frequency Attained 1
108
-
Desired Frequency Attained 2
109
-
Analog Output Signal
109
-
Analog Output Gain
110
-
Digital Output Multiplying Factor
110
-
Terminal Count Value
110
-
Preliminary Count Value
111
-
EF Active When Preliminary Count Value Attained
111
-
Fan Control
111
-
Brake Release Frequency
112
-
Brake Engage Frequency
112
-
AVI Analog Input Bias
113
-
AVI Bias Polarity
113
-
AVI Negative Bias, Reverse Motion Enable/Disable
113
-
ACI Bias Polarity
113
-
AUI Analog Input Bias
114
-
AUI Bias Polarity
114
-
AUI Input Gain
114
-
AUI Negative Bias, Reverse Motion Enable/Disable
114
-
Use of Bias
115
-
Use of Bias and Gain for Use of Full Range
115
-
Use of 0-5V Potentiometer Range Via Gain Adjustment
116
-
Use of Negative Bias in Noisy Environment
116
-
Gain Adjustment to Use Full Potentiometer
116
-
Range
116
-
0-10V Potentiometer Signal to Run Motor in FWD and REV Direction
117
-
Use Negative Slope
117
-
AVI/ACI/AUI Analog Input Delay
118
-
Analog Input Frequency Resolution
118
-
Multi-Function Input Terminals
118
-
Accel/Decel Time and Multi-Function Input Terminals
122
-
Multi-Speed Via External Terminals
123
-
Digital Terminal Input Debouncing Time
124
-
Gear Ratio for Simple Index Function
124
-
Index Angle for Simple Index Function
124
-
Deceleration Time for Simple Index Function
124
-
Multi-Step Speeds and PLC Parameters
125
-
PLC Mode
126
-
PLC Forward/Reverse Motion
128
-
Time Unit Settings
130
-
The Amplitude of Wobble Vibration
131
-
Wobble Skip Frequency
131
-
Over-Voltage Stall Prevention
132
-
Over-Current Stall Prevention During Acceleration
133
-
Over-Current Stall Prevention During Operation
133
-
Over-Torque Detection Mode
134
-
Over-Torque Detection Level
134
-
Over-Torque Detection Time
135
-
Electronic Thermal Overload Relay Selection
135
-
Electronic Thermal Characteristic
135
-
Fourth Recent Fault Record
136
-
Under-Current Detection Level
137
-
Under-Current Detection Mode
137
-
Under-Current Detection Restart Delay Time
137
-
User-Defined Low-Voltage Detection Level
137
-
Motor Rated Current
139
-
Motor No-Load Current
139
-
Torque Compensation
139
-
Slip Compensation
139
-
Number of Motor Poles
140
-
Motor Parameters Auto Tuning
140
-
Motor Line-To-Line Resistance
141
-
Motor Rated Slip
141
-
Slip Compensation Limit
141
-
Torque Compensation Time Constant
141
-
DC Braking Current Level
143
-
DC Braking Time During Start-Up
143
-
DC Braking Time During Stopping
143
-
Start-Point for DC Braking
143
-
Momentary Power Loss Operation Selection
144
-
Maximum Allowable Power Loss Time
144
-
Baseblock Time for Speed Search
144
-
Current Limit for Speed Search
145
-
Auto Reset Time at Restart after Fault
146
-
Automatic Energy-Saving
147
-
Automatic Voltage Regulation
147
-
Software Braking Level
148
-
Base Block Speed Search
148
-
B.B. Speed Search with Last Output Frequency Downward Timing Chart
149
-
B.B. Speed Search with Minimum Output Frequency Upward Timing Chart
149
-
Speed Search During Start-Up
150
-
Speed Search Frequency During Start-Up
150
-
Compensation Coefficient for Motor Instability
150
-
Communication Address
151
-
Transmission Speed
151
-
Transmission Fault Treatment
152
-
Time-Out Detection
152
-
Communication Protocol
152
-
Communication Data Frame
154
-
Address
154
-
Function and DATA
155
-
Check Sum
158
-
Address List
160
-
Exception Response
162
-
Communication Program of PC
163
-
Response Delay Time
165
-
PID Control
166
-
Input Terminal for PID Feedback
166
-
Gain over the PID Detection Value
166
-
Proportional Gain
166
-
Integral Gain
167
-
Derivative Control
167
-
Upper Bound for Integral Control
167
-
Primary Delay Filter Time
167
-
PID Output Frequency Limit
168
-
Feedback Signal Detection Time
168
-
Treatment of the Erroneous Feedback Signals
168
-
Deviation Range of PID Feedback Signal Error
169
-
PG Pulse Range
169
-
PG Input
169
-
ASR Control
170
-
Speed Control Output Frequency Limit
170
-
Sample Time for Refreshing the Content of 210DH and 210EH
170
-
Speed Control Diagram
171
-
V/F Curve Selection
172
-
Start-Up Frequency of the Auxiliary Motor
172
-
Stop Frequency of the Auxiliary Motor
172
-
Time Delay before Starting the Auxiliary Motor
173
-
Time Delay before Stopping the Auxiliary Motor
173
-
Sleep/Wake up Detection Time
174
-
Sleep Frequency
174
-
Wakeup Frequency
174
-
-
Common Problems and Solutions
177
-
-
Chapter 6 Fault Code Information
177
-
Reset
181
-
-
Chapter 7 Troubleshooting
183
-
Over Current (OC)
183
-
Ground Fault
184
-
Over Voltage
184
-
Low Voltage (Lv)
185
-
Overload
186
-
Over Heat (OH)
186
-
Display of PU01 Is Abnormal
187
-
Phase Loss
187
-
Motor Cannot Run
188
-
Motor Speed Cannot be Changed
189
-
Motor Stalls During Acceleration
190
-
The Motor Does Not Run as Expected
190
-
Daily Inspection
191
-
Periodic Inspection
191
-
-
-
Chapter 8 Maintenance and Inspections
191
-
Periodical Maintenance
192
-
-
Appendix A Specifications
197
-
All Braking Resistors and Braking Units Used in AC Motor Drives
201
-
-
Appendix B Accessories
201
-
B.1.1 Dimensions and Weights for Braking Resistors
203
-
B.1.2 Specifications for Braking Unit
205
-
B.1.3 Dimensions for Braking Unit
206
-
B.2 AMD — EMI Filter Cross Reference
207
-
Choose Suitable Motor Cable and Precautions
208
-
General Precaution
208
-
Saddle on both Ends
209
-
Saddle on One End
209
-
The Length of Motor Cable
210
-
B.2.1 Dimensions
211
-
-
B.3 PG Card (for Encoder)
219
-
PG Card and Pulse Generator
220
-
PG-02 Terminal Descriptions
222
-
Terminals
222
-
Wiring Notes
222
-
Control Terminals Block Designations
223
-
Types of Pulse Generators
223
-
B.3.2 Pg03
224
-
PG-03 Terminal Descriptions
226
-
-
B.4 Remote Controller RC-01
228
-
B.5 Remote Panel Adapter (RPA 01)
229
-
AC Input Reactor Recommended Value
230
-
B.6 AC Reactor
230
-
B.6.2 AC Output Reactor Recommended Value
231
-
Connected in Input Circuit
233
-
Correct Wiring
233
-
-
B.6.3 Applications for AC Reactor
233
-
-
B.7 Zero Phase Reactor (RF220X00A)
235
-
B.8 DC Choke Recommended Values
236
-
B.9 Non-Fuse Circuit Breaker Chart
238
-
B.10 Fuse Specification Chart
239
-
Description of the Digital Keypad VFD-PU06
241
-
Explanation of Display Message
241
-
-
B.11 Pu06
241
-
B.11.3 Operation Flow Chart
242
-
-
-
Appendix C How to Select the Right AC Motor Drive
243
-
C.1 Capacity Formulas
244
-
Selection Note
246
-
Parameter Settings Note
246
-
-
C.2 General Precaution
246
-
How to Choose a Suitable Motor
247
-
Standard Motor
247
-
Special Motors
248
-
Power Transmission Mechanism
248
-
Motor Torque
249
-
-
Advertisement
Delta VFD015B43A User Manual (179 pages)
High Performance/User-Friendly Powerful AC Motor Drives
Brand: Delta
|
Category: DC Drives
|
Size: 4.46 MB
Table of Contents
-
Getting Started
4
-
Warning
4
-
Table of Contents
6
-
Nameplate Information
9
-
Example for 1Hp/0.75Kw 3-Phase 230V AC Drive
9
-
Model Explanation
9
-
Chapter 1 Receiving and Inspections
9
-
Series Number Explanation
10
-
Storage and Installation
11
-
Ambient Conditions
11
-
-
Chapter 2 Storage and Installation
11
-
Installation
12
-
Short Circuit Withstand
13
-
General Wiring Information
13
-
Applicable Codes
13
-
-
-
Chapter 3 Wiring
13
-
Basic Wiring Diagram
14
-
Terminal Explanation
14
-
Wiring for SINK Mode and SOURCE Mode
17
-
Sink Mode
17
-
Source Mode
17
-
External Wiring
18
-
Power Supply
18
-
EMI Filter
18
-
Terminal Explanations
19
-
Control Terminals Explanations
19
-
-
Main Circuit Wiring
21
-
Control Terminal
21
-
Power Terminal
21
-
3HP to 5HP (VFD022B21A, VFD037B23A, VFD037B43A)
22
-
40 HP to 60 HP 460V (VFD300B43A, VFD370B43A, VFD450B43A)
26
-
75-100 Hp 460V (Vfd550B43A, Vfd750B43A)
27
-
-
Wiring Notes
28
-
Motor Operation Precautions
29
-
VFD-PU01 Dimensions
31
-
-
Chapter 4 Digital Keypad Operation
31
-
Description of the Digital Keypad VFD-PU01
32
-
Operation Steps of the Digital Keypad VFD-PU01
34
-
Selecting Mode
34
-
Setting Parameters
34
-
To Shift Data
34
-
Parameter Reset
35
-
Identity Code of AC Drive
35
-
-
-
Chapter 5 Description of Parameter Settings
35
-
Group 0: User Parameters
35
-
Start-Up Display Page Selection
36
-
Content of Multi Function Display
36
-
User Defined Coefficient K
36
-
Software Version
37
-
Password Decode
37
-
Password Input
37
-
Password Decode Flow Chart
38
-
Control Methods
38
-
Reserved
38
-
-
Group 1: Basic Parameters
39
-
Maximum Output Frequency (Fmax)
39
-
Maximum Voltage Frequency (Fbase)
39
-
Maximum Output Voltage (Vmax)
39
-
Minimum Output Frequency (Fmin)
40
-
Minimum Output Voltage (Vmin)
40
-
Upper Bound of Output Frequency
40
-
V/F Curve
40
-
Lower Bound of Output Frequency
41
-
Acceleration Time 1 (Taccel 1)
41
-
Deceleration Time 1 (Tdecel 1)
41
-
Jog Acceleration Time
42
-
Jog Deceleration Time
42
-
Jog Frequency
42
-
Accel/Decel Time Definition
42
-
Auto-Acceleration / Deceleration
43
-
Acceleration S-Curve
43
-
Deceleration S-Curve
43
-
Unit for Accel/Decel Time
44
-
Group 2: Operation Method Parameters
45
-
Source of First Frequency Command
45
-
Source of Second Frequency Command
45
-
Source of First Operation Command
46
-
Source of Second Operation Command
46
-
Stop Method
46
-
PWM Carrier Frequency Selections
47
-
Motor Direction Control
48
-
2-Wire/ 3-Wire Operation Control Modes
48
-
Line Start Lockout
48
-
Loss of ACI Signal (4-20Ma)
49
-
Up/Down Key Mode
49
-
Source of the Master Frequency Command (FCHA)
49
-
Source of the Auxiliary Frequency Command (FCHB)
50
-
Combination of the Master and Auxiliary Frequency Command
50
-
Keyboard Frequency Command
50
-
-
Group 3: Output Function Parameters
51
-
Multi-Function Output Terminal
51
-
Multi-Function Output Terminal MO1
51
-
Multi-Function Output Terminal MO2
51
-
Desired Frequency Attained 2
53
-
Analog Output Signal (AFM)
53
-
Analog Output Gain
53
-
Digital Output Multiplying Factor
54
-
Terminal Count Value
54
-
Preliminary Count Value
54
-
EF Active When Preliminary Count Value Attained
55
-
Fan Control
55
-
-
Group 4: Input Function Parameters
56
-
AVI Analog Input Bias
56
-
AVI Bias Polarity
56
-
AVI Input Gain
56
-
AUI Input Gain
57
-
No AUI Negative Bias Command
57
-
Max. Output Freq.
60
-
Multi-Function Input Terminal (MI1)
60
-
Multi-Function Input Terminal (MI2)
60
-
Multi-Function Input Terminal (MI3)
60
-
Digital Terminal Input Debouncing Time
64
-
AVI Analog Input Delay
64
-
ACI Analog Input Delay
64
-
AUI Analog Input Delay
64
-
Gear Ratio for Simple Index Function
65
-
Index Angle for Simple Index Function
65
-
Deceleration Time for Simple Index Function
65
-
Group 5: Multi-Step Speed and PLC (Process Logic Control) Parameters
66
-
PLC Mode
66
-
1St Step Speed Frequency
66
-
2Nd Step Speed Frequency
66
-
Continuously Executes Program Cycles
67
-
Execute One Cycle Step by Step
68
-
PLC Operation Execution One Cycle Step by Step
68
-
PLC Forward/Reverse Motion
68
-
Time Unit Settings
70
-
Skip Frequency Width
70
-
Bias Frequency Width
70
-
-
Group 6: Protection Parameters
72
-
Over-Voltage Stall Prevention
72
-
Over-Current Stall Prevention During Acceleration
72
-
Over-Current Stall Prevention During Operation
73
-
Over-Torque Detection Mode (OL2)
74
-
Over-Torque Detection Level
74
-
Over-Torque Detection Time
74
-
Electronic Thermal Overload Relay Selection
74
-
Present Fault Record
75
-
Second most Recent Fault Record
75
-
Third most Recent Fault Record
75
-
Fourth Recent Fault Record
75
-
Low-Current Detection Level
76
-
Low-Current Detection Time
76
-
Low-Current Treatment
76
-
Low-Current Detection Restart Delay Time
76
-
User-Defined Low-Voltage Detection Level
77
-
User-Defined Low-Voltage Detection Time
77
-
-
Group 7: Motor Parameters
78
-
Motor Rated Current
78
-
Motor No-Load Current
78
-
Torque Compensation
78
-
Motor Line-To-Line Resistance R1
79
-
Motor Rated Slip
79
-
Slip Compensation Limit
80
-
Torque Compensation Time Constant
80
-
Slip Compensation Time Constant
80
-
Accumulative Motor Operation Time (Min.)
80
-
-
Group 8: Special Parameters
81
-
DC Braking Current Level
81
-
DC Braking Time During Start-Up
81
-
DC Braking Time During Stopping
81
-
Momentary Power Loss Operation Selection
82
-
Maximum Allowable Power Loss Time
82
-
Baseblock Time for Speed Search (BB)
82
-
Current Limit for Speed Search
82
-
Skip Frequency 1 Upper Bound
83
-
Skip Frequency 1 Lower Bound
83
-
Auto Restart after Fault
83
-
Automatic Energy-Saving
83
-
Automatic Voltage Regulation (AVR)
84
-
Software Setting of the Braking Level
84
-
Base Block Speed Search
85
-
Speed Search During Start-Up
86
-
Speed Search Frequency During Start-Up
86
-
Auto Reset Time at Restart after Fault
87
-
Compensation Coefficient for Motor Instability
87
-
-
Group 9: Communication Parameters
88
-
Communication Address
88
-
Transmission Speed
88
-
Transmission Fault Treatment
88
-
11-Bit Character Frame (for RTU)
90
-
Communication Protocol
90
-
Communication Data Frame
90
-
ASCII Mode
90
-
Adr
91
-
CMD (Command Code) and DATA (Data Characters)
91
-
Command Message
91
-
Response Message
91
-
CHK (Check Sum)
95
-
Exception Response
99
-
Communication Program of PC
100
-
HMI Register 1
101
-
HMI Register 2
101
-
Response Delay Time
101
-
Group 10: PID Controls
102
-
Input Terminal for PID Feedback
102
-
Gain over the PID Detection Value
102
-
Proportional Gain (P)
102
-
Derivative Control (D)
103
-
Upper Bound for Integral Control
103
-
Primary Delay Filter Time
103
-
PID Output Frequency Limit
103
-
Feedback Signal Detection Time
104
-
Deviation Range of PID Feedback Signal Error
104
-
Treatment of the Erroneous Feedback Signals
104
-
PG Pulse Range
104
-
Proportional Speed Control (P)
105
-
Integral Speed Control (I)
105
-
Speed Control Output Frequency Limit
105
-
Sample Time for Refreshing the Content of 210DH and 210EH
105
-
PID Control Block Diagram
106
-
Speed Control Diagram
106
-
-
Group 11: Fan and Pump Control Parameters
107
-
V / F Curve Selection
107
-
Start-Up Frequency of the Auxiliary Motor
107
-
Stop Frequency of the Auxiliary Motor
107
-
Sleep/Wake up Detection Time
108
-
Sleep Frequency
108
-
Wakeup Frequency
109
-
-
Periodic Inspection
111
-
Periodic Maintenance
111
-
-
Chapter 6 Maintenance and Inspections
111
-
Common Problems and Solutions
113
-
-
Chapter 7 Troubleshooting and Fault Information
113
-
Emergency Stop
116
-
Ground Fault
116
-
Group 0: User Parameters
119
-
-
Chapter 8 Summary of Parameter Settings
119
-
Group 1 Basic Parameters
121
-
Group 3 Output Function Parameters
125
-
Group 4 Input Function Parameters
127
-
Group 5 Multi-Step Speed and PLC Parameters
129
-
Group 6 Protection Parameters
131
-
Group 7 Motor Parameters
133
-
Group 10: PID Control Parameters
137
-
-
Appendix A Specifications
139
-
Electrical Characteristics
141
-
Input Frequency
141
-
Output Voltage
141
-
Output Frequency
141
-
Accessories
143
-
Non-Fuse Circuit Breaker Chart
143
-
Fuse Specification Chart
144
-
All Braking Resistors & Braking Units Use in AC Drives
145
-
-
Appendix B Accessories
146
-
Braking Resistors & Braking Units
146
-
Amd — Emi Filter Corss Reference
149
-
Order P/N: RF015B21AA / RF022B43AA
150
-
Order P/N: RF022B21BA / RF037B43BA
151
-
Order P/N: RF110B43CA
152
-
Order P/N: 10TDT1W4C
153
-
Order P/N: 26TDT1W4C
153
-
Order P/N: 50TDS4W4C
154
-
Order P/N: 100TDS84C
154
-
Order P/N: 200TDDS84C
155
-
Order P/N: 150TDS84C
155
-
Order P/N: 180TDS84C
156
-
Order P/N: 20TDT1W4D
156
-
Order P/N: 26TDT1W4B4
157
-
PG Card
158
-
1 To 2HP (0.75Kw to 1.5Kw)
158
-
3 To 5HP (2.2Kw to 3.7Kw)
158
-
7.5HP (5.5Kw) and above
159
-
Basic Wiring Diagram with RPM Meter Attached
160
-
PG-02 and Pulse Generator Connections
160
-
PG-02 Terminal Descriptions
161
-
Terminals
161
-
Control Terminals Block Designations
162
-
Types of Pulse Generators
162
-
Remote Controller RC-01
163
-
VFD-B Programming
163
-
-
Remote Panel Adapter
164
-
Remote Panel Adapter for VFDPU01
164
-
Zero Phase Reactor
165
-
-
Appendix C Dimensions
167
-
VFD007B21A 0.75 Kw (1HP) 230V / 1-Phase
168
-
VFD015B21A 1.50 Kw (2HP) 230V / 1-Phase
168
-
VFD015B23A 1.50 Kw (2HP) 230V / 3-Phase
168
-
VFD015B43A 1.50 Kw (2HP) 460V / 3-Phase
168
-
VFD015B21B 1.50 Kw (2HP) 230V / 1-Phase
169
-
VFD015B23B 1.50 Kw (2HP) 230V / 3-Phase
169
-
VFD022B23B 2.20 Kw (3HP) 230V / 3-Phase
169
-
VFD022B43B 2.20 Kw (3HP) 460V / 3-Phase
169
-
2.20 Kw (3HP) 230V / 1-Phase
170
-
3.70 Kw (5HP) 230V / 3-Phase
170
-
3.70 Kw (5HP) 460V / 3-Phase
170
-
VFD055B23A 5.50 Kw (7.50HP) 230V / 3-Phase
171
-
VFD055B43A 5.50 Kw (7.50HP) 460V / 3-Phase
171
-
VFD075B23A 7.50 Kw (10.0HP) 230V / 3-Phase
171
-
VFD075B43A 7.50 Kw (10.0HP) 460V / 3-Phase
171
-
VFD150B23A 15.0 Kw (20.0HP) 230V / 3-Phase
172
-
VFD150B43A 15.0 Kw (20.0HP) 460V / 3-Phase
172
-
VFD185B23A 18.5 Kw (25.0HP) 230V / 3-Phase
172
-
VFD185B43A 18.5 Kw (25.0HP) 460V / 3-Phase
172
-
VFD300B23A 30.0 Kw (40HP) 230V / 3-Phase
173
-
VFD370B23A 37.0 Kw (50HP) 230V / 3-Phase
173
-
VFD300B43A 30.0 Kw (40HP) 460V / 3-Phase
174
-
VFD370B43A 37.0 Kw (50HP) 460V / 3-Phase
174
-
VFD450B43A 45.0 Kw (60HP) 460V / 3-Phase
174
-
VFD550B43A 55.0 Kw (75HP) 460V / 3-Phase
175
-
VFD750B43A 75.0 Kw (100HP) 460V / 3-Phase
175
-
Advertisement
Related Products
-
Delta VFD015B23A
-
Delta VFD015B53A
-
Delta VFD015B21B
-
Delta VFD015B23B
-
Delta VFD015B21A
-
Delta VFD015B43W
-
Delta VFD015EL21W
-
Delta VFD015CP43B-21
-
Delta VFD015M43B
-
Delta VFD015C23A-21
Delta Categories
Plumbing Product
Kitchen & Bath Fixtures
Saw
Bathroom Fixtures
Power Supply
More Delta Manuals
03:31
Delta Vfd-B / delta me wiring kese kare / how to wire up delta vfd
04:56
Delta vfd-B / How to install delta vfd / delta vfd ko install kese kare / factory default settings
02:22
How to factory setting delta vfd / delta vfd ko factory reset kese kare / delta vfd — B
08:27
Delta B parameter setting
01:18
Repair of DELTA VFD-B Drive VFD037B43A | Advanced Micro Services Pvt. Ltd.
02:37
Частотный преобразователь delta vfd-b
01:55
Пример настройки частотника Delta VFD-F + мануал
04:13
Настройка экрана преобразователя частоты Delta VFD-CP2000 на отображение сигнала от датчика давления
Руководство по эксплуатации Р У К О В О Д С Т В О П О Э К С…
Vfd-b, Преобразователей частоты серии
- Изображение
- Текст
1
Руководство по эксплуатации
Р У К О В О Д С Т В О
П О Э К С П Л У А Т А Ц И И
преобразователей частоты серии
VFD-B
(220 В, 0.75-2.2 кВт)
(380 В, 0.75-75 кВт)
(600 В, 0.75-75 кВт)
2010 BE16
Преобразователь частоты VFD-B
2
Revision July 2008, BE16, SW V4.08 & V5.00
3
Руководство по эксплуатации
СОДЕРЖАНИЕ
1. ВВЕДЕНИЕ ………………………………………………………………………………… 5
2. ПРИЁМКА И ПРОВЕРКА ………………………………………………………………….. 8
3. УСЛОВИЯ ТРАНСПОРТИРОВАНИЯ, ХРАНЕНИЯ, ЭКСПЛУАТАЦИИ …………………11
4. ГАБАРИТНО-УСТАНОВОЧНЫЕ РАЗМЕРЫ (мм) ……………………………………….14
5. УСТАНОВКА И ПОДКЛЮЧЕНИЕ …………………………………………………………23
5.1. Подготовка к установке и подключению…………………………………………………………23
5.2. Основные правила монтажа …………………………………………………………………………..26
5.3. Схема подключения (отрицательная логика NPN) ……………………………………………27
5.4. Назначение управляющих терминалов ………………………………………………………….28
5.5. Конфигурация дополнительного оборудования ………………………………………………29
5.6. Назначение и монтаж терминалов силового клеммника …………………………………..30
5.7. Назначение и монтаж управляющих терминалов …………………………………………….33
5.8. Общие замечания по монтажу ……………………………………………………………………..37
6. РАБОТА …………………………………………………………………………………….42
6.1. Подготовка к включению …………………………………………………………………………….42
6.2. Методы управления приводом …………………………………………………………………….43
6.3. Пробное включение ……………………………………………………………………………………43
6.4. Общие замечания по эксплуатации ………………………………………………………………44
7. ПУЛЬТ УПРАВЛЕНИЯ …………………………………………………………………….46
7.1. Описание цифровой панели управления PU 01 ……………………………………………….46
7.2. Алгоритм управления приводом с пульта управления ………………………………………47
8. ПАРАМЕТРЫ ………………………………………………………………………………49
8.1. Сводная таблица параметров ………………………………………………………………………49
8.2. Классификация параметров по назначению …………………………………………………..66
8.3. Описание программируемых параметров ……………………………………………………..72
9. ПОИСК НЕИСПРАВНОСТЕЙ И ИНФОРМАЦИЯ ОБ ОШИБКАХ …………………….. 142
10.1. Описание кодов аварий, выводимых на цифровой дисплей. …………………………. 142
10.2. Поиск неисправностей …………………………………………………………………………… 146
10. ПЕРИОДИЧЕСКИЙ ОСМОТР И ТЕХНИЧЕСКОЕ ОБСЛУЖИВАНИЕ ………………. 148
ПРИЛОЖЕНИЕ А. Технические характеристики ……………………………………… 153
ПРИЛОЖЕНИЕ В. Аксессуары …………………………………………………………. 157
В.1. Тормозные резисторы и модули ………………………………………………………………… 157
В.2. Фильтры электромагнитных полей …………………………………………………………….. 163
В.3. Платы расширения для подключения датчика обратной связи по скорости ………. 174
В.4. Пульт дистанционного управления RC 01 ……………………………………………………. 183
В.5. Адаптер (RPA 01) для выноса пульта PU 01 ………………………………………………….. 184
В.6. Дроссели переменного тока …………………………………………………………………….. 185
В.7. Рекомендуемые дроссели постоянного тока ……………………………………………….. 190
В.8. Фильтр радиопомех RF 220X00A ……………………………………………………………….. 191
В.9. Рекомендуемые параметры автоматических выключателей …………………………… 193
В.10. Рекомендуемые параметры и типы предохранителей …………………………………. 194
В.11. Пульт управления VFD-PU06 ……………………………………………………………………. 195
ПРИЛОЖЕНИЕ С. Как правильно выбрать преобразователь частоты ……………. 198
С.1. Выбор ПЧ по энергетике ………………………………………………………………………….. 199
С.2. Общие замечания по выбору и эксплуатации перобразователя частоты ………….. 202
С.3. Как выбрать подходящий двигатель …………………………………………………………… 203
ПРИЛОЖЕНИЕ D. Примеры подключения ……………………………………………. 206
Преобразователь частоты VFD-B
4
Revision July 2008, BE16, SW V4.08 & V5.00
5
Руководство по эксплуатации
1. ВВЕДЕНИЕ
Спасибо за выбор продукции компании Delta Electronics. Преобразователи VFD (далее по
тексту, ПЧ) изготавливаются из высококачественных компонентов и материалов с использо-
ванием самых современных технологий производства микропроцессорной техники. Все за-
воды компании сертифицированы по стандарту ISO9002. Преобразователи маркируются
знаком соответствия Европейским нормам CE.
Преобразователи частоты серии VFD-В предназначены для управления скоростью вра-
щения трехфазных асинхронных электродвигателей с короткозамкнутым ротором мощно-
стью от 0,4 до 75 кВт в составе такого оборудования как, насосы, вентиляторы, миксеры, экс-
трудеры, транспортирующие и подъемные механизмы и другого.
Модель VFD-B отличается:
• большим количеством функций, которые можно использовать в различных применени-
ях, что делает преобразователи этой серии универсальными;
• четыре режима управления: U/f = const, U/f = const с обратной связью по скорости, век-
торное управление в разомкнутой системе, векторное управление с обратной связью по ско-
рости.
• съемным пультом управления, который может быть вынесен с помощью опционного ка-
беля, например, на дверь электрошкафа. Вместо штатного пульта можно установить опцион-
ный пульт VFD-PU06 с функциями копирования настроек одного VFD-B на другой. Этот пульт
подключается к порту RS-485 и может быть вынесен на расстояние до 300 м с помощью теле-
фонного кабеля (витой пары);
• широкими возможностями конфигурации ПЧ (для software версии 4.08 имеется 207 па-
раметров, значения которых пользователь может изменять с пульта управления или через по-
следовательный интерфейс RS-485 с компьютера).
Преобразователи VFD-B имеют защиту от многих аварийных и нештатных режимов:
• от токов недопустимой перегрузки и короткого замыкания по выходу, в том числе от за-
мыкания выходной фазы на “землю”;
• от недопустимых перенапряжений по питанию и на шине DC;
• перегрева радиатора;
• от недопустимых отклонений и не штатного исчезновения напряжения питающей сети;
• от недопустимых отклонений технологического параметра;
• от несанкционированного доступа к программируемым параметрам (защита паролем);
• и т. д.
Настоящее руководство по эксплуатации (далее по тексту РЭ) описывает порядок хране-
ния, монтажа, подключения, эксплуатации, профилактического обслуживания, использова-
ния встроенной системы диагностики неисправностей, перечень и описание программируе-
мых параметров. В РЭ приводится перечень программируемых параметров преобразовате-
лей с версией программного обеспечения 4.08 и 5.00. Производитель оставляет за со-
бой право на изменения конструкции и программного обеспечения ПЧ без предварительно-
го уведомления пользователей.
Перед использованием ПЧ внимательно прочитайте данное руководство. Строго соблю-
дайте требования техники безопасности. Особое внимание в руководстве уделите внимание
местам с пометками “ОПАСНОСТЬ”, которые предполагают, что неправильное обращение
может вызвать тяжелые травмы или смерть или вызвать повреждения материального имуще-
ства; “ВНИМАНИЕ” и “ПРЕДОСТЕРЕЖЕНИЕ” – которые предполагают, что неправильное об-
ращение может вызвать легкие травмы или телесные повреждения или вызвать повреждения
Глава 1. Введение
Преобразователь частоты VFD-B
6
Revision July 2008, BE16, SW V4.08 & V5.00
материального имущества. Учтите, что нарушение указаний, помеченных как “ВНИМАНИЕ” и
“ПРЕДОСТЕРЕЖЕНИЕ”, также могут привести к серьезным последствиям, в зависимости от
конкретных условий. Следуйте, пожалуйста, указаниям всех разделов, так как они важны для
безопасности персонала.
Указания по безопасности!
ОПАСНОСТЬ!
•
Не подавайте напряжение питания на преобразователь со снятой передней крышкой. Вы мо-
жете дотронуться до открытых токопроводящих частей с электрическим потенциалом до 800В и получить
удар током.
•
Запрещается производить какие-либо подсоединения к клеммам преобразователя, открывать
защитные элементы, разбирать корпус при подключенном напряжении сети и до истечения 10 мин после
отключения питания, так как заряженные конденсаторы сохраняют опасное напряжение на токонесущих
элементах в течение некоторого времени после отключения сети.
•
Запрещается самостоятельно разбирать, модифицировать или ремонтировать преобразова-
тель. Это может привести к удару током, пожару или иным повреждениям. По вопросу ремонта обращай-
тесь к поставщику.
•
Запрещается, даже случайно, присоединять выходные клеммы U/T1, V/T2, W/T3 к питающей
сети, так как это заведомо приведет к полному разрушению преобразователя, пожару или иным повреж-
дениям, а также снятию гарантийных обязательств Поставщика. Необходимо специально проконтролиро-
вать этот момент на предмет возможной ошибки.
•
Преобразователь должен быть надежно заземлен с помощью зажима (E).
•
Используйте в качестве нагрузки только трехфазный асинхронный двигатель. Подсоединение
любого другого оборудования может привести к неисправностям.
•
Данный ПЧ не предназначен для использования в оборудовании, сбои в работе которого могут
повлечь за собой непосредственную угрозу человеческой жизни (устройства управления ядерной энер-
гией, авиацией и космическими полётами, системами жизнеобеспечения и т.д.) Если Вы собираетесь ис-
пользовать ПЧ для каких-либо специальных целей, прежде всего, посоветуйтесь с поставщиком.
ВНИМАНИЕ!
•
Не производите испытание повышенным напряжением (мегомметром и др.) каких-либо частей
ПЧ. До начала измерений на кабеле или двигателе отсоедините кабель двигателя от преобразователя.
•
На печатных платах преобразователя расположены чувствительные к статическому электриче-
ству электронные компоненты. Во избежание повреждения элементов или цепей на печатных платах, не
следует касаться их голыми руками, либо металлическими предметами.
•
Работы по подключению, пуско-наладке и обслуживанию должны производиться только квали-
фицированным персоналом, изучившим настоящее руководство.
ВНИМАНИЕ!
В случае если изделие перемещено из холодного помещения в теплое, на внешних и внутренних по-
верхностях может образоваться конденсат, что может привести к повреждению электронных компонен-
тов. Поэтому перед вводом в эксплуатацию необходимо выдержать изделие без упаковки при комнатной
температуре в течении не менее 4 часов. Не подключайте силовое питание до исчезновения всех видимых
признаков наличия конденсата.
7
Руководство по эксплуатации
ПРЕДОСТЕРЕЖЕНИЕ!
•
Настройки некоторых параметров позволяют ПЧ запустить двигатель сразу после подачи на-
пряжения питания или осуществить автоматическое повторное включение после аварии. Поместите пред-
упреждение о возможности внезапного запуска на оборудование для предотвращения несчастных случа-
ев.
•
Если произошел сбой в работе преобразователя, отключите его. Длительное протекание боль-
шого тока может привести к возгоранию.
•
ПЧ имеет степень защиты IP20 и является электрическим оборудованием, предназначенным
для установки в шкафы управления или аналогичные закрытые рабочие пространства со степенью защиты
обеспечивающей требуемые условия эксплуатации.
•
Устанавливайте ПЧ только на невоспламеняющиеся (металлические) объекты. Задняя панель
сильно нагревается, и контакт с воспламеняющимися объектами может привести к возгоранию.
•
Не допускайте контакта ПЧ с водой или другими жидкостями. Не допускайте попадание внутрь
преобразователя пыли, кусков провода и других инородных тел при проведении подключения и обслужи-
вания.
•
Не работайте с преобразователем, если его части повреждены или отсутствуют.
•
Не кладите и не ставьте тяжелые предметы на преобразователь.
•
Использование ПЧ должно осуществляться строго в соответствии с условиями, описанными в
данной инструкции.
•
Для предотвращения повреждений прикладывайте к клеммам преобразователя только указан-
ные в данном руководстве напряжения.
•
При включенном питании и некоторое время, сразу после его отключения, не прикасайтесь к
преобразователю и тормозному резистору, которые нагреваются. Это может привести к ожогам.
•
Дети и другой неподготовленный персонал не должны иметь доступ к ПЧ.
•
Не присоединяйте на выход преобразователя емкостные элементы, такие как конденсаторы
коррекции коэффициента мощности, помехоподавляющий фильтр, ограничитель импульсных помех и т.д.
•
Порядок подключения выходных кабелей U, V, W к двигателю влияет на направление его враще-
ния.
•
Не используйте контактор на входе преобразователя для запуска/останова. Используйте для
этой цели стартовые команды.
•
Для снижения уровня электромагнитных помех, используйте рекомендованные фильтры. В про-
тивном случае может быть оказано негативное влияние на расположенные рядом электронные устрой-
ства.
•
Используйте двигатели с повышенным уровнем изоляции или примите меры для подавления
импульсов перенапряжения. Перенапряжения могут возникать на клеммах двигателя при длинном мотор-
ном кабеле, ухудшая его изоляцию. Для предотвращения этого может потребоваться использование мо-
торного дросселя (см. приложение B).
•
Преобразователь может работать в высокоскоростном режиме. Перед установкой этого режи-
ма, проверьте способность двигателя и привода работать на повышенных скоростях.
•
Перед использованием преобразователя, хранившегося длительное время, обязательно осу-
ществляйте его осмотр, проверку, а возможно и формование конденсаторов.
Невыполнение требований, изложенных в настоящем РЭ, может привести к отказам,
вплоть до выхода ПЧ из строя.
При невыполнении потребителем требований и рекомендаций настоящего руковод-
ства Поставщик может снять с себя гарантийные обязательства по бесплатному ремон-
ту отказавшего преобразователя!
Поставщик также не несёт гарантийной ответственности по ремонту при несанкцио-
нированной модификации ПЧ, при грубых ошибках настройки параметров ПЧ и выборе
неверного алгоритма работы.
Глава 1. Введение
Преобразователь частоты VFD-B
8
Revision July 2008, BE16, SW V4.08 & V5.00
2. ПРИЁМКА И ПРОВЕРКА
Преобразователи прошли контроль качества у производителя и входной контроль у По-
ставщика, однако, после получения преобразователя, следует проверить, не наступили ли
повреждения во время транспортировки.
Проверьте полученный комплект, который, в базовом варианте, должен состоять из:
• собственно преобразователя частоты;
• настоящего руководства по эксплуатации;
• гарантийного талона, который может быть в составе настоящего РЭ.
Убедитесь, что тип и номинальные данные на паспортной табличке (шильдике) ПЧ соответ-
ствуют заказу.
Пример для ПЧ 0.75кВт 3-ф/230В AC :
Расшифровка обозначения модели ПЧ:
Расшифровка серийного номера:
Руководство по эксплуатации В случае обнаружения, каких…
Страница 9
- Изображение
- Текст
9
Руководство по эксплуатации
В случае обнаружения, каких–либо несоответствий, повреждений и т.д., пожалуй-
ста, обратитесь к поставщику.
Типоразмеры VFD-B:
Габарит
Мощность
Модели
A
0.75 кВт
VFD007B23A/43A/53A
A1
0.75-1.5 кВт
VFD007B21A, VFD015B21A/23A/43A/53A
A2
1.5-2.2 кВт
VFD015B21B/23B, VFD022B23B/43B/53A
B
2.2-3.7 кВт
VFD022B21A, VFD037B23A/43A/53A
C
5.5-11 кВт
VFD055B23A/43A/53A, VFD075B23A/43A/53A, VFD110B23A/43A/53A
D
15-22 кВт
VFD150B23A/43A/53A, VFD185B23A/43A/53A, VFD220B23A/43A/53A
E
30-45 кВт
VFD300B43A/53A, VFD370B43A/53A, VFD450B43A/53A
E1
30-75 кВт
VFD300B23A, VFD370B23A, VFD550B43C/53A, VFD750B43C/53A
Габаритно-установочные размеры указаны в главе 4.
Внешний вид:
0.75-2.2кВт (Типоразмеры A, A1, A2)
2.2-3.7кВт (Типоразмер B)
Глава 2. Приемка и проверка
Преобразователь частоты VFD-B
10
Revision July 2008, BE16, SW V4.08 & V5.00
5.5-11кВт (Типоразмер C)
15-22кВт (Типоразмер D)
30-75кВт (Типоразмер E, E1)
55-75кВт (Типоразмер F)
3. УСЛОВИЯ ТРАНСПОРТИРОВАНИЯ,
ХРАНЕНИЯ И ЭКСПЛУАТАЦИИ
Комментарии
Delta Electronics VFD-B
Универсальные преобразователи частоты общего назначения
- Выходная частота: 0~400Гц (0~2000Гц)
- Настраиваемая характеристика V/F и векторное управление
- Основной и дополнительный источники задания частоты
- 15 предустановленных скоростей
- Автоматическое пошаговое управление
- ПИД-регулятор
- Автоматическая компенсация момента и скольжения
- Связь по MODBUS (скорость до 38400 бит/сек), а так же модули Profibus DP, DeviseNet, LonWorks
Векторное управление в разомкнутом и замкнутом контуре; Автотестирование двигателя; Управление группой электродвигателей
Uпит, В | Диапазон мощностей, кВт |
---|---|
1Ф/220В | 0.75 — 2.2 |
3Ф/220В | 0.75 — 37 |
3Ф/380В | 0.75 — 75 |