Thank you for selecting the ZOOM 506 (hereafter simply called the «506»).

Please take the time to read this manual carefully so as to get the most out of

your 506 and to ensure optimum performance and reliability. Retain this manual

for future reference.

ZOOM CORPORATION

NOAH Bldg., 2-10-2, Miyanishi-cho, Fuchu-shi, Tokyo 183, Japan

PHONE: 0423-69-7111 FAX: 0423-69-7115

Major Features

1

• 24 individual built-in effects provide maximum flexibility.

Up to 8 effects can be used simultaneously in any combination.

• Memory capacity for up to 24 user-programmable patches.

• Integrated auto-chromatic bass guitar tuner for simple and precise tuning

anywhere.

• Optional foot controller FP01 can be used for pedal wah or pedal pitch, and

volume control is also possible.

• Optional foot switch FS01 can be used for bank switching, resulting in

enhanced playability.

• Dual power supply principle allows the unit to be powered from an alkaline

battery or an AC adapter.

• New DSP (digital signal processor) ZFx-2 developed by Zoom produces

high-quality effects from an amazingly compact package.

Safety Precautions

2

USAGE AND SAFETY PRECAUTIONS

In this manual, symbols are used to highlight warnings and

cautions for you to read so that accidents can be prevented. The

meanings of these symbols are as follows:

This symbol indicates explanations about extremely

dangerous matters. If users ignore this symbol and

handle the device the wrong way, serious injury or

Warning

death could result.

This symbol indicates explanations about dangerous

matters. If users ignore this symbol and handle the

device the wrong way, bodily injury and damage to the

Caution

equipment could result.

Please observe the following safety tips and precautions to ensure

hazard-free use of the 506.

About power

Warning

Since power consumption of this unit is fairly high, we

recommend the use of an AC adapter whenever possible.

When powering the unit from a battery, use only an alkaline

type.

AC adapter operation

• Be sure to use only an AC adapter which supplies 9 V DC,

300 mA and is equipped with a «center minus» plug (Zoom

AD-0006). The use of an adapter other than the specified type

may damage the unit and pose a safety hazard.

• Connect the AC adapter only to an AC outlet that supplies the

rated voltage required by the adapter.

• When disconnecting the AC adapter from the AC outlet,

always grasp the adapter itself and do not pull at the cable.

• If the unit is not to be used for a long time, disconnect the AC

adapter from the outlet.

Battery operation

• Use only a 9 V (alkaline) battery (6LR61).

• The 506 cannot be used for recharging.

Pay close attention to the labelling of the battery to make sure

you choose the correct type.

• If the 506 is not to be used for an extended period of time,

remove the battery from the unit.

• If battery leakage has occurred, wipe the battery compartment

and the battery terminals carefully to remove all remnants of

battery fluid.

• While using the unit, the battery compartment cover should

be closed.

Environment

Caution

Avoid using your 506 in environments where it will be

exposed to:

• Extreme temperature

• High humidity or moisture

• Excessive dust or sand

• Excessive vibration or shock

Handling

Caution

• The 506 is a precision instrument. Except for the foot

switches, do not push other parts with your feet or subject

them to strong force.

• Take care that no foreign objects (coins or pins etc.) or liquids

can enter the unit.

• Be sure to turn the power to all equipment off before making

connections.

• Before moving the unit, turn the power off, and disconnect all

cables and the AC adapter.

Alterations

Caution

Never open the case of the 506 or attempt to modify the

product in any way since this can result in damage to the unit.

Operation Manual

Printed in Japan 506-5000

Usage precautions

Electrical interference

For safety considerations, the 506 has been designed to provide

maximum protection against the emission of electromagnetic

radiation from inside the device, and from external

interference.However, equipment that is very susceptible to

interference or that emits powerful electromagnetic waves

should not be placed near the 506, as the possibility of

interference cannot be ruled out entirely.

Whatever the type of digital control device, the 506 included,

electromagnetic damage can cause malfunctioning, and can

corrupt or destroy data. Since this is an ever-present danger,

thorough care should be taken to minimize the risk of damage.

Cleaning

Use a soft, dry cloth to clean the 506. If necessary, slightly

moisten the cloth. Do not use abrasive cleanser, wax, or

solvents (such as paint thinner or cleaning alcohol), since these

may dull the finish or damage the surface.

Connecting cables and input and output jacks

You should always turn off the power to the 506 and all other

equipment before connecting or disconnecting any cables. Also

make sure to disconnect all cables and the AC adapter before

moving the 506.

Ожидается изображения товара

249 

Инструкция (руководство пользователя) на Процессор эффектов ZOOM 506-II Bass

Артикул: zoom-506-ii-bass

Категория: ZOOM

  • Описание

  • Детали

Описание

Инструкцию по эксплуатации ZOOM 506-II Bass на русском языке можно будет скачать в личном кабинете после оформления и оплаты заказа.

Детали

Формат файла

PDF

Размер инструкции в кб

544

7

Bank switching

Banks A, b, C, d, E, F are available

PATCH

PATCH

DOWN

UP

Patch switching

24 patches are available

The 24 patches can be selected easily by

pressing the patch pedals. The right patch

pedal switches to the next patch and the

left patch pedal switches to the previous

patch.

In the initial condition, the 506 is set up

so that the patch pedals select patches

continuously, but you can also set up the

unit so that patches are switched only

within a certain bank [see the section

«Patch Switching (Application: Bank

Hold»)].

Bank switching is performed with the

VALUE + / — keys.

If for example the currently selected patch

is patch 2 of bank A, and you want to

switch to patch 3 of bank C, you would

need to press the UP pedal nine times.

Instead, you can press the VALUE + key

twice and then the UP pedal once.

If the optional FS01 is connected to the

CONTROL IN jack on the rear panel, the

foot switch can be used as a bank UP

pedal. This allows full foot control, which

is highly convenient during a

performance.

Using the Bypass (Mute)/Tuner Mode

8

In the Bypass mode, the effects of

the 506 are temporarily turned off,

so that the original sound of the

instrument only is heard. In this

mode, the auto-chromatic tuning

function is also active. It is also

possible to activate muting, to

prevent the tuning sound from

being sent to the output.

Press both

pedals together

Bypass and mute condition

Pressing both patch pedals simultaneously activates the Bypass or Mute mode.

• For bypass mode: Press and immediately release the patch pedals.

Currently selected

patch is indicated

• For mute mode: Press patch pedals for at least 1 second.

Currently selected

patch is indicated

To cancel the bypass or mute condition, simply press one of the patch pedals. The unit then

reverts to the previously selected patch.

Tuning function

When the 506 is in the Bypass or Mute mode, the tuning function is activated automatically. Pick

an open string to be tuned. The closest note is shown on the display.

Input signal

standby condition

w

? w

?

Do = C

w

? #w

?

Do# = C#

#w

? w

Regular tuning

?

Re = D

2nd string

w

#w

Regular tuning

?

?

Re# = D#

When the tuning function is active, the

parameter cursor LEDs serve as tuning

meter, designed to enhance tuning

precision when making fine adjustments.

BANK F

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK E

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK UP

BANK d

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK C

PATCH 1

PATCH 2

BANK DOWN

PATCH 3

PATCH 4

BANK b

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK A

PATCH 1

PATCH 2

PATCH 3

Bank/patch switching

PATCH 4

when Bank Hold is off

Calibration

Select reference pitch for auto-chromatic

bass guitar tuner (calibration)

* Reference pitch (A) can be adjusted in

the range from 435 to 445 Hz. This is

shown as «35» to «45» on the display.

The normal setting is 440 Hz (40).

Bypass (Mute)/Tuner mode ON

Pressing both patch pedals simultaneously turns

the Bypass (Mute)/Tuner mode on. To turn the

mode off, simply press one of the two patch pedals.

Press

Release immediately

Press for 1 s or more

Release

#w

Regular tuning

4th string

?

Mi = E

So# = G#

w

Regular tuning

?

Fa = F

La = A

#w

?

Fa# = F#

La# = A#

w

?

So = G

Si = B

1st string

Pitch is too high

Correctly tuned

Tuner mode

Mute mode

3rd string

Pitch is too low

Понравилась статья? Поделить с друзьями: